GREEN NICOYA

GREEN NICOYA is a 1995 towing vessel. The Coast Guard has recorded 17 inspections since 2022, most recently in January 2026, along with 26 deficiencies.

Records from 2022 to 2026. Most recent: inspection, 26 January 2026.

Built
1995
Last inspected
26 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 26 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2022–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9130884
PJM0701
1706005
Flag
CURACAO
Maury page id
psix-1706005

Documentation record

Tonnage as PSIX records it223 - Convention (Subpart B), Gross Ton
66 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KINNICK 3200 Freight Barge · MISLE 1706786 · 5 November 2022 · activity 7589852

Inspection history · 17

26 January 2026 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8301625
21 June 2025 PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8163285
13 June 2025 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8158444
10 June 2025 CCSSC Examination · PSC A
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8156159
9 December 2024 CCSSC Examination · PSC A
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8044875
25 November 2024 CCSSC Examination · PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8039147
23 April 2024 CCSSC Examination · PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7898155
8 November 2023 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7822079
23 October 2023 CCSSC Examination · PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7811318
13 April 2023 Administrative Inspection · Deficiency Check · PSC B · CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7667730
21 November 2022 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7597926
5 November 2022 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7589852
5 November 2022 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7589854
2 October 2022 CCSSC Examination · PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7568408
1 July 2022 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7492324
4 May 2022 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7431649
29 March 2022 Administrative Inspection · PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7419795

Deficiency record · 26

02 - Structural Conditions › N/A - No Subsystem › Damage control plan
Issued 10 June 2025 Resolved
Electrical installations should be such that the safety of personnel and ship from electrical hazards will be assured. PSCO identified multiple splices that were installed improperly on the vessel's lighting system and generator sets. CCSSC Ch.2 31.1.3
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2025
Resolved 13 June 2025
Resolution: Crew installed junction boxes to all the locations that improper electical wiring was identified.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 10 June 2025 Resolved
Fixed fire detection and fire alarm systems required by this chapter should comply, as far as is practicable and reasonable, with the relevent requirements for these systems specified in the regulations for these systems specified in the regulations of the 1974 SOLAS convention. PSCO identified that the smoke detectors in the galley were dismantled and not capable of detection. CCSSC CH.3, 8.1
Action required: 10 - Deficiency Rectified
Due 10 June 2025
Resolved 14 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 December 2024 Resolved
A Classification Society must not review, examine, survey or certify the construction, repair or alteration of a vessel in the United States unless it is approved under the provisions of this subpart. The vessel's Caribbean Cargo Ship Safety Certificate were issued by an unapproved Classification Society in Houston, TX, USA. 46CFR 2.45-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2024
Resolved 16 December 2024
Resolution: Vessel submitted an updated Caribbean Cargo Safety Certificate that was issued outside of the United States.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 November 2024 Resolved
The liferaft painter system shall provide a connection between the ship and the liferaft and shall be so arranged as to ensure that the liferaft when released and, in the case of an inflatable liferaft, inflated is not dragged under by the sinking ship. Vessels portside liferaft’s painter line was attached to the ship and not the weak link provided on the hydrostatic release. LSA 4.1.6.1 (CCSSC 4.3.1)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2024
Resolved 5 December 2024
Resolution: The liferat's painter line was correctly re-attached to the hydrostatic weak link.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 November 2024 Resolved
The satellite EPIRB and VHF EPIRB referred to in 5.13.1 and 5.13.2 should be: capable of floating free if the ship sinks and of being automatically activated when afloat. Vessels EPIRB’s housing was taped together rendering the hydrostatic release useless and unable to release if activated. CCSSC Ch. 5.13.3.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2024
Resolved 5 December 2024
Resolution: All the tape was removed from the EPIRB housing.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 November 2024 Resolved
Electrical installations should be such that the safety of personnel and the ship from electrical hazards are assured. Dead end wiring, exposed junction boxes/wires and alterations where wires were spliced and branching from existing power sources existed in excess throughout almost every space within the vessel. Most notable locations were the galley/messroom, crewmembers cabins, in the head/laundry room, and within the engine room. CCSSC 2.13.1.3
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2024
Resolved 5 December 2024
Resolution: Wiring throughout the ship was properly run through conduit and into junction boxes. Any dead-end wiring was removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 25 November 2024 Resolved
The owner or master of every ship to which this code applies should ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship, persons on board or the environment. Vessels CCSSC requires the vessel to have on board 02 line throwing guns. Vessel currently only has 01 on board. CCSSC 1.11.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2024
Resolved 5 December 2024
Resolution: Vessel aquired a second line-throwing gun.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 November 2024 Resolved
Suitable arrangements should be made to the satisfaction of the Administration for embarkation into survival craft which should include means for illuminating the stowage position of survival craft and their launching appliances during preparation for and the process of launching, and also for illuminating the water into which the survival craft are launched until the process of launching is completed. The survival craft illumination on the starboard side of the vessel was not mounted and the wires were cut from their power source. The portside had to be tied to the railing of the ship as the mount had deteriorated and instead of illuminating the portside survival craft location, it instead illuminated directly away from the ship to port. CCSSC 4.10.1.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2024
Resolved 5 December 2024
Resolution: Vessel properly mounted and wired both liferaft embarkation emergency lighting.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 November 2024 Resolved
The bulkheads and decks separating the machinery spaces of category A from control stations, corridors, accommodation spaces, stairways, services spaces, and cargo spaces should be so constructed to be capable of preventing the spread of fire to the unexposed side. The engine room door leading into the main passageway is unable to be closed, the door is not aligned, there is a bolt protruding out of the hinge, and the self-closing mechanism does not work appropriately. CCSSC Ch. 3.16.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2024
Resolved 5 December 2024
Resolution: Engineroom door fixed to be properly operating.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 November 2024 Resolved
Stairways and ladders should be so arrange as to provide, from accommodation spaces, services spaces, control stations, machinery spaces and other spaces in which the crew is normally employed, ready means of escape to the open deck and thence to the survival craft. The access to a ladder in the engine room was blocked by a large pile of oily rans, a swab, and bucket of oily water. CCSSC Ch 3.16.4.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2024
Resolved 5 December 2024
Resolution: All obstructions were removed from engineroom.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 25 November 2024 Resolved
All machinery and electrical installations, mechanical and electrical equipment and appliances, boilers and other pressure vessels, associated piping systems, fittings and electrical cables and wiring should be of a design and construction adequate for the service for which they are intended and should be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. Vessel’s engine room had several missing deck plates, while others were unstable which would teeter and fall when stepped on. Multiple lightbulbs within the engine room were exposed and did not have covers protecting them. CCSSC 2.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2024
Resolved 5 December 2024
Resolution: Light covers and deckplates were replaced and fitted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2024 Resolved
Steps and recesses in bulkheads should be watertight and as strong as the bulkhead at the place where each occurs. Vessel crew had drilled holes through multiple steel frames of porthole windows to run tv antenna lines into the vessel, no longer maintaining their watertight integrity. CCSSC 2.7.3.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2024
Resolution: TV cable removed and through holes welded shut.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 25 November 2024 Resolved
Where a cooking range requires an exhaust hood and duct, this should be fitted with a grease trap. The exhaust hood and duct were not fitted with a grease trap and had excessive grease in the duct. CCSSC Ch. 3.22.4
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2024
Resolution: Grease trap fitted in the exhaust hood.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 November 2024 Resolved
The fireman’s outfits or sets of personal equipment should be stored as to be easily accessible and ready for use. The access to fireman’s outfits were blocked by equipment and vessel stores. CCSSC Ch. 3.11.5
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2024
Resolved 5 December 2024
Resolution: All obstructions were removed from in front of the fireman's locker.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 November 2024 Resolved
Handrails, grabrails, and handholds of sufficient size and strength should be provided where necessary in the opinion of the Administration for persons to hold on when the ship is severely rolling or pitching. The handrail and grabrail to the freezer from the galley are not secure. CCSSC Ch. 2.12.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2024
Resolution: Railings were tightened up and secure.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 November 2024 Resolved
A fireman’s outfit should consist of personnel equipment comprising of an axe to the satisfaction of the administration. One fireman’s outfit did not have an axe located with the suit, as outlined in 3.2.7 of the vessel’s CCSSC Certificate. CCSSC Ch. 3.11.2.1.5
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2024
Resolution: Both axes were stored with the firemans suits.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2023 Resolved
CCSSC 2.31.2 Electrical installations should be such that uniformity in the implementation and application of the provisions of this part will be ensured. PSCO observed an extensionn cord running from engine room to port side running light.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 November 2023
Resolution: Attended vessel, nav light in working condition. Extension cord removed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 April 2023 Resolved
Electrical installations should be such that uniformity in the implemetation of the provisions of this part will be ensured (IEC publication 92). Replace twist on wire nuts with appropriate butt connectors on installed fire fighting device in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2023
Resolved 25 April 2023
Resolution: Installed within an enclosure.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 April 2023 Resolved
In every ship there should be provided for the protection of any space containing internal combustion type machinery having a total power output of 750 KW and above: one of the fixed fire extinguishing systems referred to in 3.10.1. The vessel's fixed CO2 System in the engine room is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2023
Resolved 14 April 2023
Resolution: Technicians came on board and completed installation of CO2 system. Provided tech report.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 April 2023 Resolved
Every ship of less than 300gt should by 01 February, 1999, carry at least one satellite EPIRB capable of transmitting a distress alert. The vessel's EPIRB had an expired battery.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2023
Resolved 14 April 2023
Resolution: Vessel replaced EPIRB.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 5 November 2022 Resolved
CCSSC Ch. 2 Part A 2.3 - All machinery, mechanical, and associate systems should be designed and constructed for adequate service for which they are intended and in working condition for the environment in which they operate. Vessel grounded and lost its starboard main engine.
Action required: 15 - Rectify deficiencies by next port
Due 15 November 2022
Resolved 21 November 2022
Resolution: Receieved tech report attesting to satisfactory repair.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 29 March 2022 Resolved
The emergency fire pump should be capable of producing at least a jet of water of not less than 6M from one hydrant. Ships emergency fire pump was inoperable at the time of exam. 97 CCSS Code 3.3.7.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2022
Resolution: Ship repaired Emergency fire pump and demonstrated satisfactory operation to PSCOs.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 29 March 2022 Resolved
The owner or master of every ship to which this Code applies should ensure that: after any survey of the ship under 1.10, no significant change should be made to other items. Ships required secondary line throwing appliance was expired. 97 CCSS Code 1.11.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2022
Resolution: Ship procured a secondary line throwing device that was placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 29 March 2022 Resolved
Rescue boat launching arrangements should be such that the rescue boat can be launched in the shortest possible time. No quick release hook installed on the rescue boat. 97 CCSS Code 4.10.2.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 1 July 2022
Resolution: Recieved invoice of release.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 March 2022 Resolved
All electrical installations should be so installed to reduce danger to persons on board. Ship had exposed wires on a 120v circuit in the engine room. 97 CCSS Code 2.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2022
Resolved 30 March 2022
Resolution: PSCOs witnessed proper repair of the deficient wiring onboard.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 29 March 2022 Resolved
Every ship of 100 gross tonnage shall carry a garbage management plan. Ship did not have a copy of the Garbage management plan on board. Marpol CONS 2011 Annex V Reg 10.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2022
Resolved 1 July 2022
Resolution: Recieved picture of Garbage Management Plan.