Records from 2021 to 2026. Most recent: inspection, 3 August 2026.
Inspection history · 36
3 August 2026
Explosive Handling Operation-Military
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8447676
3 April 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8341488
1 April 2026
MSP Annual Oversight · Administrative Inspection · MSP Select Handover Survey · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8340469
30 March 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8333810
19 August 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8213454
15 August 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8210588
12 August 2025
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8218344
24 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8166099
21 March 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8097379
5 March 2025
Administrative Inspection · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8088981
19 February 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8081243
18 February 2025
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8082789
17 February 2025
Type not recorded
No type recorded · Activities Europe · Activity 8173050
10 January 2025
Deficiency Check · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8061046
28 August 2024
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7992674
23 July 2024
Underwater Inspection in lieu of Drydock
Physical examination · Activities Europe · Activity 7964741
9 April 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7892193
21 March 2024
Administrative Inspection · MTSA/ISPS Verification · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7883170
16 March 2024
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7877886
13 October 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7811845
7 June 2023
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7707974
11 May 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7685849
25 April 2023
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7675559
25 April 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7676138
3 February 2023
Annual Inspection · MSP Annual Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7631503
30 January 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7629940
25 January 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626794
25 January 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7628922
29 December 2022
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7614357
25 December 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7612965
22 December 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7612211
14 October 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7577446
17 June 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7482223
4 April 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7423960
2 April 2022
Type not recorded
No type recorded · Activities Europe · Activity 7430000
3 December 2021
Reflagging & Initial Certification · COI Inspection · Administrative Inspection
Physical examination · Activities Europe · Activity 7364402
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 August 2025
Resolved
Each Captain of the Port may order a vessel to operate in the manner directed when the Captain of the Port has determined that such order is justified in the interest of safety by reason of weather, visibility, sea conditions, temporary port congestions, other temporary hazards circumstances, or the condition of the vessel.
While transiting to through the Sector Virginia regulated navigation area (RNA), as defined by Title 33, Code of Federal Regulation (CFR), 165.501 (a)(2): your vessel shall be escorted by either:
- One tug of not less than 3,000 horsepower and one tug of not less than 2,000 horsepower, or;
- Two tugs of not less than 50 Ton Aggregate Bollard Pull, or;
- One tug of not less than 50 Ton Bollard Pull.
33 CFR 160.111(c)
Action required: 705 - Other - as specified
Resolved 25 August 2025
Resolution: VSL corrected issue with steering gear and submitted tech and class reports.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 March 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea.
Observed fractures and wastage of dry storage deck due to salt water intrusion.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 March 2025
Resolved
Where penetrations of watertight bulkheads are necessary for access arrangements are to made to maintain watertight integrity.
Starboard bridge wing gear locker watertight door knife edge holed/wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 March 2025
Resolved
Where A class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, etc, arrangements shall be made to ensure that the fire resistance is not impaired.
A-60 aft bulkhead in CO2 room found with open pipe
penetration into adjacent hvac compartment.
74 SOLAS (14) II-2/14.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 March 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Both lifeboats found with severely wasted or missing mounting brackets for fuel tanks.
74 SOLAS (14) III/20.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 March 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured.
1. Multiple grounding wires for lighting fixtures and ventilation fans found broken or missing throughout vessel exterior decks.
2. Reefer electrical gang boxes in cargo area found with broken covers sealed with electrical tape.
74 SOLAS (14) II-1/40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 March 2025
Resolved
Internal combustion engines of 2,250 kW and above or having cylinders of more than 300 mm bore shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices.
Ten oil mist detectors found to be inoperable and not working as intended.
74 SOLAS (14) II-1/47.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2025
Resolved
A fixed fire detection and fire alarm system shall be installed in machinery spaces.
Marine inspector found broken fire detection head on the middle level of the engine room.
74 SOLAS14 II-2/4.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 March 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
1. Port lifeboat found with fire extinguisher that had not received annual servicing.
2. Starboard lifeboat found with multiple deteriorated/broken straps.
74 SOLAS (14) III/20.1
Action required: 10 - Deficiency Rectified
Resolved 5 March 2025
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 23 July 2024
Resolved
12107- Fire Protection Cargo Deck Area-Electrical Equipment shall not be fitted in enclosed cargo spaces unless essential for operational purposes...equipment shall be certified safe type for use in the dangerous environment to which it is exposed. Cargo hold #1 light found destroyed by previous event. Repair or replace light with fixture certified safe type for the enclosed cargo space. SOLAS 74 Amend(20 Consolidated) II-2/19.3.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2024
Resolution: 15AUG2024: Recieved photographic evidence of replaced light, with new explosion proof enclosure. All Sat.
//s// [name withheld], LTJG
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2024
Resolved
07199- Other (Fire Safety)- The ignitability of combustibles shall be restricted. #7 Cargo hold, centerline HFO line expansion joints were found missing flashing. A drip pan undeath the fitting had accumulation of oil. Vessel is required to replace the flashing and ensure fitting is secure to prevent leaks. SOLAS 74 Amend(20 Consolidated) II-2/4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2024
Resolution: 15AUG24: Received photographic evidence of replaced lagging and flashing. All sat.
//s// [name withheld], LTJG
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2024
Resolved
07199- Other (Fire Safety) Means to control leaks of flammable liquids. #6 cargo hold had HFO line was found missing flashing at piping. Vessel is required to replace missing flashing. SOLAS 74 Amend(20 Consolidated) II-2/4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2024
Resolution: 15AUG24: Received photographic evidence of replaced lagging and flashing. All sat.
//s// [name withheld], LTJG
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2024
Resolved
02199- Other(Structural Condition)- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Inspector identified corroded brackets on the exterior port quarter fire main risers. Vessel is required to repair/replace the bracket to orginal condition. SOLAS 74 Amend(20 Consolidated) I/11.a
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2024
Resolved 20 August 2024
Resolution: 20AUG24: Recieved photographic evidence of new welded repairs to fire main system.
//s// [name withheld], LTJG
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2024
Resolved
02199- Other (Structural Condition)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Make repairs to pin holed Grey Water overboard piping above turn in piping on inboard side of skin valve. SOLAS 74 Amend (20 Consolidated) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2024
Resolved 9 September 2024
Resolution: 06SEP24: Vessel master submitted pictures of grey water pipe replaced new.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 July 2024
Resolved
01104-Cargo Ship Safety Radio- The Coast Guard may delegate issuance of the certain international convention certificates to a recognized classification societies. A SOLAS Cargo Ship Safety Radio Certificate issued by Lloyd’s Register was found on board. Certificate issued on 10FEB2024 in Port of Houston, USA. Remove certificate and maintain valid FCC Safety Radio Certificate. 46CFR8.320(b)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 August 2024
Resolution: MI confirmed removal of certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 July 2024
Resolved
01104-Cargo Ship Safey Radio- A certificate called a Cargo Ship Safety Radio Certificate shall be issued after an initial or renewal survey to a cargo ship which complies with the relevant requirements of chapter IV and any other relevant requirements of the present regulations. A valid Safety Radio Certificate issued by approved FCC licensed authority found with incorrect gross tonnage. Correct certificate upon return to US port. SOLAS 74 Amend (20 Consolidated) I/12.a.iv
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 August 2024
Resolution: Reviewed new certificate, uploaded to certs tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 March 2024
Resolved
Before the ship leaves ports and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Starboard lifeboat rudder is inoperable due to a cracked internal drive mechanism of the steering column. SOLAS 74 (2020 Con. Ed.) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2024
Resolved 16 March 2024
Resolution: Steering wheel, internal drive mechanism and cables now replaced by
manufacturers representative. Steering gear system examined, tested and now found satisfactory by CG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 March 2024
Resolved
Before the ship leaves ports and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Starboard lifeboat batteries found to have low voltage during weekly test. SOLAS 74 (2020 Con. Ed.) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2024
Resolved 16 March 2024
Resolution: The battery charger had a loose cable/wire that the crew cleaned and repaired. The charger tested satisfactory in presence of ACS Surveyor. Batteries replaced in kind with new batteries. Witnessed starting of lifeboat with both batteries.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 16 March 2024
Resolved
Immediately after addressing of resultant safety concerns, the owner, agent, master, operator, or person in charge, shall notify the nearest Sector Office, Marine Inspection Office, or Coast Guard Group Office whenever a vessel is involved in a marine casualty, consisting in an occurrence materially and adversely affecting the vessel's lifesaving equipment. Vessel master did not report marine casualty to the nearest Marine Inspection Office, USCG Activities Europe (ACTEUR). Marine casualty occurred in ACTEUR's marine inspection zone. 46 CFR 4.05-1(a)(4)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2024
Resolved 16 March 2024
Resolution: Verified vessel SMS and educated Master on CG reporting requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 February 2023
Resolved
Before ship leaves port and at all times during the
voyage, all life-saving appliance shall be in good
working order.
Marine Inspectors observed Port lifeboat could not be
lowered in it's entirety to the water due to the remote
brake cable not being adjusted correctly. Stop would hit
entrance point of lifeboat. Crew had to adjust slack to
remote brake cable in order for it to lower. Servicing
company attended and corrected issue. Tech stated cable
was too 100m, when the requirement is 49m.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2023
Resolution: Vessel had tech come out and correct issue. MI verified proper operation.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 February 2023
Resolved
Exhaust ducts from galley ranges shall meet the
requirements of paragraphs 7.2.1.2.1 and 7.2.1.2.2: the
ducts are insulated to "A-60" class standard throughout
the accommodation spaces, service spaces or control
stations.
Marine Inspector discovered galley vent hood had hole in
bottom section and temporarily repaired with a piece of
metal sheeting.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiceny.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 February 2023
Resolved
Direct access to the embarkation deck by way of external
open stairways and passageways shall be provided
and shall have emergency lighting in accordance with
regulation III/11.5 and slip-free surfaces underfoot.
Marine Inspector discovered multiple emergency lights on
the port and starboard side muster/embarkation stations
extinguished.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR acceped deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2023
Resolved
Ships shall be designed, constructed and maintained in
compliance with the structural, mechanical and
electrical requirements of a classification society
which is recognized by the Administration.
Marine Inspector discovered electrical junction boxes on
aft superstructure missing protective caps.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 February 2023
Resolved
Freeing ports, open rails and scuppers shall be fitted
as necessary for rapidly clearing the weather deck of
water under all weather conditions.
Marine Inspector discovered clogged scuppers on upper
deck aft of superstructure.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepeted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 February 2023
Resolved
Muster and embarkation stations shall be adequately
illuminated by lighting supplied from the emergency
source of electrical power required by regulation
II-1/42 or II-1/43, as appropriate.
Marine Inspector discovered all flood lights on port and
starboard side muster stations missing grounding wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 February 2023
Resolved
Except as provided in regulations I/7(b)(ii), I/8 and
I/9, while all reasonable steps shall be taken to
maintain the equipment required by this chapter in
efficient working order.
Marine Inspector discovered aft anchor light falling off
of mounting surface.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 February 2023
Resolved
Guard rails or bulwark shall be fitted around all
exposed decks.
Guard rails on STBD Focsle had damage and broken weld.
Guard rail on the FWD Port side of A deck had broken
guard rails.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 3 February 2023
Resolved
Rescue boats shall be stowed: in a state on continuous
readiness for launching in not more than 5 min.
Rescue boats outfit was stored in STBD life boat. Rescue
boats steering column was wasted and loose. The breaker
boat was broken and exposed to environment, and the
rescue boat battery was stored in a milk crate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2023
Resolved
Before ship leaves port and at all times during the
voyage, all life-saving appliance shall be in good
working order.
Lifejackets had holes cut into them for previous outfit
of lights. Lights were removed, leaving large 3” long by
2” deep hole. Rendering lifejackets not serviceable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 3 February 2023
Resolved
At least three two-way VHF radio telephones apparatus
shall be provided for every passenger ship and cargo
ship of 500 gross tonnage and upwards.
VHR Radios on bridge were not stowed in accordance with
Fire Control Plan. Two radios charging stations are hard
wired in to locations that are not mentioned on Fire
Control Plan or are not marked by the appropriate
symbol.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepeted deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 February 2023
Resolved
Lifebuoys complying shall be stowed as to be capable of
being rapidly cast loose and not permanently secured in
any way and shall be fitted with self-igniting light.
Self-igniting light of lifebuoy at bay 58 Port side did
not work. Light was seized in bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2023
Resolved
Fire-fighting systems and appliances shall be kept in
good working order and readily available for immediate
use.
Fire hose on Port bridge wing had leak during testing of
emergency fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 February 2023
Resolved
The machinery, boilers and other pressure vessels,
associated piping systems and fittings shall be of a
design and construction adequate for the service for
which they are intended.
Main salt water cooling seal failure resulting in salt
water ingress.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepeted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 3 February 2023
Resolved
Every steam pipe and every fitting connected thereto
through which steam may pass shall be so designed,
constructed and installed as to withstand the maximum
working stresses to which it may be subjected.
Jacket water heater flange failure resulting in
discharge of steam into engineering space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2023
Resolved
Electrical installations shall be such that the safety
of passengers, crew and ship from electrical hazards
shall be ensured.
Ground cable on remote actuated valve for Ballast Water
Treatment System broken.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2023
Resolved
Electrical installations shall be such that the safety
of passengers, crew and ship from electrical hazards
shall be ensured.
Dead end wiring in overhead of vestibule outside CO2
room from pre-existing lighting fixture.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 February 2023
Resolved
Means shall be provided to control leaks of flammable
liquids.
Excessive fuel oil and lube oil in engine room bilge and
in cylinder head containment areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepeted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 February 2023
Resolved
The means of escape shall have emergency lighting
provisions.
Emergency lighting extinguished in purifier room and
engine room escape.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 3 February 2023
Resolved
Electrical services essential for safety will be ensured
under various emergency conditions.
Linksys sensor system experiencing intermittent failures
in communications of vital system monitoring.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 3 February 2023
Resolved
The machinery, boilers and other pressure vessels,
associated piping systems and fittings shall be of a
design and construction adequate for the service for
which they are intended.
Starboard bunker header pressure gauge inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 February 2023
Resolved
The construction of doors and door frames in "A" class
divisions, with the means of securing them
when closed, shall provide resistance to fire as well as
to the passage of smoke and flame equivalent to
that of the bulkheads in which the doors are situated,
this being determined in accordance with the Fire
Test Procedures Code.
Marine Inspector discovered galley fire door wasted at
bottom edge and unable to automatically close
completely.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2023
Resolved
Fire protection systems and appliances shall be
maintained ready for use.
Fire damper emergency generator room seized. Corrected
on spot.
Action required: 10 - Deficiency Rectified
Resolved 3 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 February 2022
Resolved
Main engine F/O injection pump control oil nonmetallic hoses were excessively worn, had no date of manufacturer. SMS requires verification of date of manufacturer for 10 year shelf-life and requires replacement if found worn. Accepted by LR during reflag.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 23 February 2022
Resolution: Accepted by LR as condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 December 2021
Resolved
Starboard lifeboat damaged upon operational lowering of lifeboat. Lifeboat kort nozzle & keel were damaged. The cable for the remote control wire parted causing the lifeboat to swing which caused the damage. Accepted by LR during reflag.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 9 February 2022
Resolution: Accepted by LR as condition of class.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 December 2021
Resolved
Port steering pump loss of phase alarm was found inoperable during operational test. Accepted by LR during reflag.
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 23 February 2022
Resolution: Accepted by LR as condition of class.