MAURY USCG vessel records
← All vessels

MAERSK KANSAS

MAERSK KANSAS is a freight ship. The Coast Guard has recorded 36 inspections since 2021, most recently in August 2026, along with 45 deficiencies, 4 operational controls and 4 casualty investigations between 2022 and 2025.

Records from 2021 to 2026. Most recent: inspection, 3 August 2026.

Built
Not recorded
Last inspected
3 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 August 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2021–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9311701
1706305
Flag
UNITED STATES
Maury page id
psix-1706305

Documentation record

Registered dimensions (L × B × D)912.5 ft × 105.8 ft × 61.4 ft
Registered tonnagegross 50,442 / net 27,284
ITC dimensions (L × B × D)912.5 ft × 105.8 ft × 61.4 ft
ITC tonnagegross 50,442 / net 27,284
BuilderHYUNDAI HEAVY INDUSTRIES CORP LTD · ULSAN, KOREA, REPUBLIC OF
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsRegistry, Canadian bulk freight
DocumentationValid · issued 9 August 2025 · expires 30 September 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61454 - Dead Weight, Metric Ton
50442 - Convention (Subpart B), Gross Ton
27284 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 36

3 August 2026 Explosive Handling Operation-Military
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8447676
3 April 2026 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8341488
1 April 2026 MSP Annual Oversight · Administrative Inspection · MSP Select Handover Survey · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8340469
30 March 2026 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8333810
19 August 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8213454
15 August 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8210588
12 August 2025 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8218344
24 June 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8166099
21 March 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8097379
5 March 2025 Administrative Inspection · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8088981
19 February 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8081243
18 February 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8082789
17 February 2025 Type not recorded
No type recorded · Activities Europe · Activity 8173050
10 January 2025 Deficiency Check · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8061046
28 August 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7992674
23 July 2024 Underwater Inspection in lieu of Drydock
Physical examination · Activities Europe · Activity 7964741
9 April 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7892193
21 March 2024 Administrative Inspection · MTSA/ISPS Verification · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7883170
16 March 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7877886
13 October 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7811845
7 June 2023 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7707974
11 May 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7685849
25 April 2023 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7675559
25 April 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7676138
3 February 2023 Annual Inspection · MSP Annual Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7631503
30 January 2023 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7629940
25 January 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626794
25 January 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7628922
29 December 2022 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7614357
25 December 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7612965
22 December 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7612211
14 October 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7577446
17 June 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7482223
4 April 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7423960
2 April 2022 Type not recorded
No type recorded · Activities Europe · Activity 7430000
3 December 2021 Reflagging & Initial Certification · COI Inspection · Administrative Inspection
Physical examination · Activities Europe · Activity 7364402

Deficiency record · 45

10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 August 2025 Resolved
Each Captain of the Port may order a vessel to operate in the manner directed when the Captain of the Port has determined that such order is justified in the interest of safety by reason of weather, visibility, sea conditions, temporary port congestions, other temporary hazards circumstances, or the condition of the vessel. While transiting to through the Sector Virginia regulated navigation area (RNA), as defined by Title 33, Code of Federal Regulation (CFR), 165.501 (a)(2): your vessel shall be escorted by either: - One tug of not less than 3,000 horsepower and one tug of not less than 2,000 horsepower, or; - Two tugs of not less than 50 Ton Aggregate Bollard Pull, or; - One tug of not less than 50 Ton Bollard Pull. 33 CFR 160.111(c)
Action required: 705 - Other - as specified
Resolved 25 August 2025
Resolution: VSL corrected issue with steering gear and submitted tech and class reports.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 March 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Observed fractures and wastage of dry storage deck due to salt water intrusion.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 March 2025 Resolved
Where penetrations of watertight bulkheads are necessary for access arrangements are to made to maintain watertight integrity. Starboard bridge wing gear locker watertight door knife edge holed/wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 March 2025 Resolved
Where A class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, etc, arrangements shall be made to ensure that the fire resistance is not impaired. A-60 aft bulkhead in CO2 room found with open pipe penetration into adjacent hvac compartment. 74 SOLAS (14) II-2/14.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 March 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Both lifeboats found with severely wasted or missing mounting brackets for fuel tanks. 74 SOLAS (14) III/20.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 March 2025 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. 1. Multiple grounding wires for lighting fixtures and ventilation fans found broken or missing throughout vessel exterior decks. 2. Reefer electrical gang boxes in cargo area found with broken covers sealed with electrical tape. 74 SOLAS (14) II-1/40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 March 2025 Resolved
Internal combustion engines of 2,250 kW and above or having cylinders of more than 300 mm bore shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices. Ten oil mist detectors found to be inoperable and not working as intended. 74 SOLAS (14) II-1/47.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2025 Resolved
A fixed fire detection and fire alarm system shall be installed in machinery spaces. Marine inspector found broken fire detection head on the middle level of the engine room. 74 SOLAS14 II-2/4.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 19 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 March 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. 1. Port lifeboat found with fire extinguisher that had not received annual servicing. 2. Starboard lifeboat found with multiple deteriorated/broken straps. 74 SOLAS (14) III/20.1
Action required: 10 - Deficiency Rectified
Resolved 5 March 2025
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 23 July 2024 Resolved
12107- Fire Protection Cargo Deck Area-Electrical Equipment shall not be fitted in enclosed cargo spaces unless essential for operational purposes...equipment shall be certified safe type for use in the dangerous environment to which it is exposed. Cargo hold #1 light found destroyed by previous event. Repair or replace light with fixture certified safe type for the enclosed cargo space. SOLAS 74 Amend(20 Consolidated) II-2/19.3.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2024
Resolution: 15AUG2024: Recieved photographic evidence of replaced light, with new explosion proof enclosure. All Sat. //s// [name withheld], LTJG
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2024 Resolved
07199- Other (Fire Safety)- The ignitability of combustibles shall be restricted. #7 Cargo hold, centerline HFO line expansion joints were found missing flashing. A drip pan undeath the fitting had accumulation of oil. Vessel is required to replace the flashing and ensure fitting is secure to prevent leaks. SOLAS 74 Amend(20 Consolidated) II-2/4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2024
Resolution: 15AUG24: Received photographic evidence of replaced lagging and flashing. All sat. //s// [name withheld], LTJG
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2024 Resolved
07199- Other (Fire Safety) Means to control leaks of flammable liquids. #6 cargo hold had HFO line was found missing flashing at piping. Vessel is required to replace missing flashing. SOLAS 74 Amend(20 Consolidated) II-2/4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2024
Resolution: 15AUG24: Received photographic evidence of replaced lagging and flashing. All sat. //s// [name withheld], LTJG
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2024 Resolved
02199- Other(Structural Condition)- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Inspector identified corroded brackets on the exterior port quarter fire main risers. Vessel is required to repair/replace the bracket to orginal condition. SOLAS 74 Amend(20 Consolidated) I/11.a
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2024
Resolved 20 August 2024
Resolution: 20AUG24: Recieved photographic evidence of new welded repairs to fire main system. //s// [name withheld], LTJG
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2024 Resolved
02199- Other (Structural Condition)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Make repairs to pin holed Grey Water overboard piping above turn in piping on inboard side of skin valve. SOLAS 74 Amend (20 Consolidated) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2024
Resolved 9 September 2024
Resolution: 06SEP24: Vessel master submitted pictures of grey water pipe replaced new.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 July 2024 Resolved
01104-Cargo Ship Safety Radio- The Coast Guard may delegate issuance of the certain international convention certificates to a recognized classification societies. A SOLAS Cargo Ship Safety Radio Certificate issued by Lloyd’s Register was found on board. Certificate issued on 10FEB2024 in Port of Houston, USA. Remove certificate and maintain valid FCC Safety Radio Certificate. 46CFR8.320(b)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 August 2024
Resolution: MI confirmed removal of certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 July 2024 Resolved
01104-Cargo Ship Safey Radio- A certificate called a Cargo Ship Safety Radio Certificate shall be issued after an initial or renewal survey to a cargo ship which complies with the relevant requirements of chapter IV and any other relevant requirements of the present regulations. A valid Safety Radio Certificate issued by approved FCC licensed authority found with incorrect gross tonnage. Correct certificate upon return to US port. SOLAS 74 Amend (20 Consolidated) I/12.a.iv
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 August 2024
Resolution: Reviewed new certificate, uploaded to certs tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 March 2024 Resolved
Before the ship leaves ports and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Starboard lifeboat rudder is inoperable due to a cracked internal drive mechanism of the steering column. SOLAS 74 (2020 Con. Ed.) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2024
Resolved 16 March 2024
Resolution: Steering wheel, internal drive mechanism and cables now replaced by manufacturers representative. Steering gear system examined, tested and now found satisfactory by CG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 March 2024 Resolved
Before the ship leaves ports and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Starboard lifeboat batteries found to have low voltage during weekly test. SOLAS 74 (2020 Con. Ed.) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2024
Resolved 16 March 2024
Resolution: The battery charger had a loose cable/wire that the crew cleaned and repaired. The charger tested satisfactory in presence of ACS Surveyor. Batteries replaced in kind with new batteries. Witnessed starting of lifeboat with both batteries.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 16 March 2024 Resolved
Immediately after addressing of resultant safety concerns, the owner, agent, master, operator, or person in charge, shall notify the nearest Sector Office, Marine Inspection Office, or Coast Guard Group Office whenever a vessel is involved in a marine casualty, consisting in an occurrence materially and adversely affecting the vessel's lifesaving equipment. Vessel master did not report marine casualty to the nearest Marine Inspection Office, USCG Activities Europe (ACTEUR). Marine casualty occurred in ACTEUR's marine inspection zone. 46 CFR 4.05-1(a)(4)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2024
Resolved 16 March 2024
Resolution: Verified vessel SMS and educated Master on CG reporting requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 February 2023 Resolved
Before ship leaves port and at all times during the voyage, all life-saving appliance shall be in good working order. Marine Inspectors observed Port lifeboat could not be lowered in it's entirety to the water due to the remote brake cable not being adjusted correctly. Stop would hit entrance point of lifeboat. Crew had to adjust slack to remote brake cable in order for it to lower. Servicing company attended and corrected issue. Tech stated cable was too 100m, when the requirement is 49m.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2023
Resolution: Vessel had tech come out and correct issue. MI verified proper operation.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 February 2023 Resolved
Exhaust ducts from galley ranges shall meet the requirements of paragraphs 7.2.1.2.1 and 7.2.1.2.2: the ducts are insulated to "A-60" class standard throughout the accommodation spaces, service spaces or control stations. Marine Inspector discovered galley vent hood had hole in bottom section and temporarily repaired with a piece of metal sheeting.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiceny.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 February 2023 Resolved
Direct access to the embarkation deck by way of external open stairways and passageways shall be provided and shall have emergency lighting in accordance with regulation III/11.5 and slip-free surfaces underfoot. Marine Inspector discovered multiple emergency lights on the port and starboard side muster/embarkation stations extinguished.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR acceped deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2023 Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration. Marine Inspector discovered electrical junction boxes on aft superstructure missing protective caps.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 February 2023 Resolved
Freeing ports, open rails and scuppers shall be fitted as necessary for rapidly clearing the weather deck of water under all weather conditions. Marine Inspector discovered clogged scuppers on upper deck aft of superstructure.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepeted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 February 2023 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43, as appropriate. Marine Inspector discovered all flood lights on port and starboard side muster stations missing grounding wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 February 2023 Resolved
Except as provided in regulations I/7(b)(ii), I/8 and I/9, while all reasonable steps shall be taken to maintain the equipment required by this chapter in efficient working order. Marine Inspector discovered aft anchor light falling off of mounting surface.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 February 2023 Resolved
Guard rails or bulwark shall be fitted around all exposed decks. Guard rails on STBD Focsle had damage and broken weld. Guard rail on the FWD Port side of A deck had broken guard rails.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 3 February 2023 Resolved
Rescue boats shall be stowed: in a state on continuous readiness for launching in not more than 5 min. Rescue boats outfit was stored in STBD life boat. Rescue boats steering column was wasted and loose. The breaker boat was broken and exposed to environment, and the rescue boat battery was stored in a milk crate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2023 Resolved
Before ship leaves port and at all times during the voyage, all life-saving appliance shall be in good working order. Lifejackets had holes cut into them for previous outfit of lights. Lights were removed, leaving large 3” long by 2” deep hole. Rendering lifejackets not serviceable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 3 February 2023 Resolved
At least three two-way VHF radio telephones apparatus shall be provided for every passenger ship and cargo ship of 500 gross tonnage and upwards. VHR Radios on bridge were not stowed in accordance with Fire Control Plan. Two radios charging stations are hard wired in to locations that are not mentioned on Fire Control Plan or are not marked by the appropriate symbol.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepeted deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 February 2023 Resolved
Lifebuoys complying shall be stowed as to be capable of being rapidly cast loose and not permanently secured in any way and shall be fitted with self-igniting light. Self-igniting light of lifebuoy at bay 58 Port side did not work. Light was seized in bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2023 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire hose on Port bridge wing had leak during testing of emergency fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 February 2023 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Main salt water cooling seal failure resulting in salt water ingress.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepeted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 3 February 2023 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. Jacket water heater flange failure resulting in discharge of steam into engineering space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2023 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. Ground cable on remote actuated valve for Ballast Water Treatment System broken.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2023 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. Dead end wiring in overhead of vestibule outside CO2 room from pre-existing lighting fixture.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 February 2023 Resolved
Means shall be provided to control leaks of flammable liquids. Excessive fuel oil and lube oil in engine room bilge and in cylinder head containment areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepeted deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 February 2023 Resolved
The means of escape shall have emergency lighting provisions. Emergency lighting extinguished in purifier room and engine room escape.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 3 February 2023 Resolved
Electrical services essential for safety will be ensured under various emergency conditions. Linksys sensor system experiencing intermittent failures in communications of vital system monitoring.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 3 February 2023 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Starboard bunker header pressure gauge inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 February 2023 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated, this being determined in accordance with the Fire Test Procedures Code. Marine Inspector discovered galley fire door wasted at bottom edge and unable to automatically close completely.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
Resolution: LR accepted deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2023 Resolved
Fire protection systems and appliances shall be maintained ready for use. Fire damper emergency generator room seized. Corrected on spot.
Action required: 10 - Deficiency Rectified
Resolved 3 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 February 2022 Resolved
Main engine F/O injection pump control oil nonmetallic hoses were excessively worn, had no date of manufacturer. SMS requires verification of date of manufacturer for 10 year shelf-life and requires replacement if found worn. Accepted by LR during reflag.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 23 February 2022
Resolution: Accepted by LR as condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 December 2021 Resolved
Starboard lifeboat damaged upon operational lowering of lifeboat. Lifeboat kort nozzle & keel were damaged. The cable for the remote control wire parted causing the lifeboat to swing which caused the damage. Accepted by LR during reflag.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 9 February 2022
Resolution: Accepted by LR as condition of class.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 December 2021 Resolved
Port steering pump loss of phase alarm was found inoperable during operational test. Accepted by LR during reflag.
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 23 February 2022
Resolution: Accepted by LR as condition of class.

Casualty record · 4

2 April 2022Routine · role: Involved in a Marine Casualty · 1 injured · activity 7430000
25 April 2023Routine · role: Involved in a Marine Casualty · activity 7676138
17 February 2025Routine · role: Involved in a Marine Casualty · activity 8173050
12 August 2025Routine · role: Involved in a Marine Casualty · activity 8218344
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.