This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it92752 - Convention (Subpart B), Gross Ton 181458 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
1 February 2022Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7389049
30 November 2021PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7357448
All steering gear components shall be of sound and reliable construction to the satisfaction of the Administration. PSCO observed excessive hydraulic fluid leaking from number 1 steering pump. 74 SOLAS (14 Cons) II-1/29.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 February 2022
Resolution: Received class report clearing listed deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 November 2021Resolved
In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapor. PSCO observed wasted insulation on all fuel injection lines on M/E. 74 SOLAS (09) II-2/4.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 February 2022
Resolution: Received class report clearing listed deficiency.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.