GRAND AMBITION is a tank ship. The Coast Guard has recorded 6 inspections since 2022, most recently in November 2025, along with 1 deficiency and 1 operational control.
Records from 2022 to 2025. Most recent: inspection, 24 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it156392 - Regulatory (Subpart C or D), Gross Ton 106250 - Convention (Subpart B), Net Ton 106250 - Regulatory (Subpart C or D), Net Ton 299988 - Dead Weight, Metric Ton 342756 - Displacement, Metric Ton 156392 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 6
24 November 2025COC-TVE Renew
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8268073
9 August 2024COE-Administrative · COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7965686
9 August 2024Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7965943
27 July 2024Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7968193
23 June 2023PSC B · Deficiency Check · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7710488
9 March 2022COC-TVE Renew · Administrative Inspection · PSC A
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7404425
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 23 June 2023Resolved
The cargo discharge piping of all tank vessels shall be tested at least once each year for tightness, at the maximum working pressure. Vessel has not done annual hydrostatic piping test.
46 CFR 35.35-70(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2023
Resolved 5 July 2023
Resolution: Vessel provided documentation of hydrostatic test conducted 30 June 2023
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.