VIKING MARS

VIKING MARS is a 2022 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2021, most recently in September 2025, along with 8 deficiencies.

Records from 2021 to 2025. Most recent: inspection, 24 September 2025.

Built
2022
Last inspected
24 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9833187
1710808
Flag
NORWAY
Maury page id
psix-1710808

Inspections, by type

Years with a record 4 calendar years (2021–2025)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it3640 - Dead Weight, Ton
25774 - Displacement, Ton
18865 - Convention (Subpart B), Net Ton
47842 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 9

24 September 2025 PSC A · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8229301
13 March 2025 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8092758
3 January 2025 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8057033
10 October 2024 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8017461
24 September 2024 PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8005343
2 March 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7872032
13 November 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7823837
5 October 2023 Ballast Water Examination · PSC A · COC-CVE Initial
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7802781
30 December 2021 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 7373755

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 September 2024 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. When testing water mist system in main vertical zone 4 deck A (forward crew stairwell), system did not activate. 74 SOLAS (20) II-2/14.2.1.2
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2024
Resolved 22 December 2024
Resolution: See TPO report uploaded 22Dec2024.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 September 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: the approximate time of closure for hinged fire doors shall be... no less than 10s from the beginning of their movement. 03 hinged fire doors for the listed area types, including doors A.4.01, 2.1.04, and 7.3.01, closed in a time quicker than the requirement. 74 SOLAS (20) II-2/9.4.1.1.5.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2024
Resolution: Doors corrected while onboard
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 March 2024 Resolved
FIRE DOORS IN MAIN VERTICAL ZONE BULKHEADS, GALLEY BOUNDARIES AND STAIRWAY ENCLOSURES, HOLDBACK HOOKS NOT SUBJECT TO CENTRAL CONTROL STATION RELEASE ARE PROHIBITED. PSCO'S OBSERVED FIRE DOOR LEADING INTO THE GARBAGE ROOM WAS HELD BACK BY LINE/STRING. 74SOLAS20 II-2/9.4.1.1.5.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 March 2024
Resolution: VESSEL CREW REMOVED HOLD BACK HOOK AND DOOR IS NOW OPERATING AS IT IS INTENDED TO.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 March 2024 Resolved
ALLEYWAY, STAIRWAY AND EXITS GIVING ACCESS TO THE MUSTER AND EMBARKATION STATIONS SHALL BE LIGHTED. SUCH LIGHTING SHALL BE CAPABLE OG BEING SUPPLIED BY THE EMEERGENCY SOURCE OF ELECTRICAL POWER. IN ADDITION ROUTES TO MUSTER STATIONS SHALL BE INDICATED WITH THE MUSTER. STATION SYMBOL, INTENDED FOR THAT PURPOSE. PSCO'S OBSERVED EMERGENCY LIGHTING ABOVE THE EXIT DOOR LEADING TO THE EMBARKATION DECK ON DECK 2 mvz4 DOOR 003 WAS EXTINGUISHED. 74 SOLAS 20 III/11.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 March 2024
Resolution: VESSEL CREW FIXED EMERGENCY LIGHT ABOVE EXIT SO IT NOW ILLUMINATES WHEN ENTERING THE SPACE.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 March 2024 Resolved
THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET SCAPE ROUTES SHALL BE MAINTAINED IN A SAFE CONDITION, CLEAR OF OBSTACLES. PSCO'S OBSERVED A CHAIR AND BOXES BLOCKING THE ESAPE FROM THE ENGINE ROOM AND ON DECK ALPHA FORWARD IN THE CREW CABIN, THE CORRIDOR WAS BLOCKED BY TROLLY SUPPLIES. 74 SOLAS 20-2/13.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 March 2024
Resolution: VESSEL CREW CLEARED MEANS OF ESCAPE.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 October 2023 Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed a sliding glass door in a Class "A0" fire boundary in the vicinity of the aft dining hall on deck two. This door was self opening and closing. The integrity of the "A0" boundary cannot be maintained in its operating state as it is motion activated with no failsafe cutoff. Action Code: 50ac Deficiency Code: 07103 Cite: 74 SOLAS 20 II-2/9.1.3
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 13 November 2023
Resolution: Recieved report from [name withheld] attesting to the ship not needing a remote closing system or power failsafe cut off. Attached email correspondance in Documents Tab.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2023 Resolved
After any survey of the ship under 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanctions of the administration. PSCO observed fuel oil line from settling tank to be missing insulation at connection points in line and isolation valves. Action Code: 10c Deficiency Code: 02199 Cite: 74 SOLAS 20/1.11.b
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 October 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occur: structural openings and penetrations in these divisions. PSCO observed self closing fire doors 3.2.03 and 3.1.10A unable to self-close without assistance. Action Code: 10c Deficiency Code: 07105 Cite: 74 SOLAS 20 II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023