Records from 2021 to 2025. Most recent: inspection, 24 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
24 September 2025
PSC A · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8229301
13 March 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8092758
3 January 2025
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8057033
10 October 2024
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8017461
24 September 2024
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8005343
2 March 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7872032
13 November 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7823837
5 October 2023
Ballast Water Examination · PSC A · COC-CVE Initial
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7802781
30 December 2021
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 7373755
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 September 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. When testing water mist system in main vertical zone 4 deck A (forward crew stairwell), system did not activate.
74 SOLAS (20) II-2/14.2.1.2
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2024
Resolved 22 December 2024
Resolution: See TPO report uploaded 22Dec2024.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 September 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: the approximate time of closure for hinged fire doors shall be... no less than 10s from the beginning of their movement. 03 hinged fire doors for the listed area types, including doors A.4.01, 2.1.04, and 7.3.01, closed in a time quicker than the requirement.
74 SOLAS (20) II-2/9.4.1.1.5.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2024
Resolution: Doors corrected while onboard
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 March 2024
Resolved
FIRE DOORS IN MAIN VERTICAL ZONE BULKHEADS, GALLEY BOUNDARIES AND STAIRWAY ENCLOSURES, HOLDBACK HOOKS NOT SUBJECT TO CENTRAL CONTROL STATION RELEASE ARE PROHIBITED.
PSCO'S OBSERVED FIRE DOOR LEADING INTO THE GARBAGE ROOM WAS HELD BACK BY LINE/STRING.
74SOLAS20 II-2/9.4.1.1.5.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 March 2024
Resolution: VESSEL CREW REMOVED HOLD BACK HOOK AND DOOR IS NOW OPERATING AS IT IS INTENDED TO.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 March 2024
Resolved
ALLEYWAY, STAIRWAY AND EXITS GIVING ACCESS TO THE MUSTER AND EMBARKATION STATIONS SHALL BE LIGHTED. SUCH LIGHTING SHALL BE CAPABLE OG BEING SUPPLIED BY THE EMEERGENCY SOURCE OF ELECTRICAL POWER. IN ADDITION ROUTES TO MUSTER STATIONS SHALL BE INDICATED WITH THE MUSTER. STATION SYMBOL, INTENDED FOR THAT PURPOSE. PSCO'S OBSERVED EMERGENCY LIGHTING ABOVE THE EXIT DOOR LEADING TO THE EMBARKATION DECK ON DECK 2 mvz4 DOOR 003 WAS EXTINGUISHED.
74 SOLAS 20 III/11.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 March 2024
Resolution: VESSEL CREW FIXED EMERGENCY LIGHT ABOVE EXIT SO IT NOW ILLUMINATES WHEN ENTERING THE SPACE.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 March 2024
Resolved
THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET SCAPE ROUTES SHALL BE MAINTAINED IN A SAFE CONDITION, CLEAR OF OBSTACLES. PSCO'S OBSERVED A CHAIR AND BOXES BLOCKING THE ESAPE FROM THE ENGINE ROOM AND ON DECK ALPHA FORWARD IN THE CREW CABIN, THE CORRIDOR WAS BLOCKED BY TROLLY SUPPLIES.
74 SOLAS 20-2/13.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 March 2024
Resolution: VESSEL CREW CLEARED MEANS OF ESCAPE.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 October 2023
Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed a sliding glass door in a Class "A0" fire boundary in the vicinity of the aft dining hall on deck two. This door was self opening and closing. The integrity of the "A0" boundary cannot be maintained in its operating state as it is motion activated with no failsafe cutoff.
Action Code: 50ac
Deficiency Code: 07103
Cite: 74 SOLAS 20 II-2/9.1.3
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 13 November 2023
Resolution: Recieved report from [name withheld] attesting to the ship not needing a remote closing system or power failsafe cut off. Attached email correspondance in Documents Tab.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2023
Resolved
After any survey of the ship under 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanctions of the administration. PSCO observed fuel oil line from settling tank to be missing insulation at connection points in line and isolation valves.
Action Code: 10c
Deficiency Code: 02199
Cite: 74 SOLAS 20/1.11.b
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 October 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occur: structural openings and penetrations in these divisions. PSCO observed self closing fire doors 3.2.03 and 3.1.10A unable to self-close without assistance.
Action Code: 10c
Deficiency Code: 07105
Cite: 74 SOLAS 20 II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023