MAURY USCG vessel records
← All vessels

AUNT DONNA

Built
1979
Last inspected
1 August 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 1 August 2025
…with no type recorded15
Operational controls 1 with no removal date recorded
Years with a record 17 calendar years (1997–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD2630
171094
Flag
UNITED STATES
Maury page id
psix-171094

Documentation record

Registered dimensions (L × B × D)55.8 ft × 24.2 ft × 8.1 ft
Registered tonnagegross 105 / net 71
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF OUTLET MARINE REPAIR · NEW ORLEANS, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPOMPANO BEACH, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 10 July 2025 · expires 31 July 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it105 - Regulatory (Subpart C or D), Gross Ton
71 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each, 2 without one; 1 operational control with no removal date recorded; 1 other vessel inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BEHEMOTH Freight Barge · MISLE 47006 · 9 September 2016 · activity 6075388

Inspection history · 30

1 August 2025 Examination of Repairs · Drydock Exam · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8202340
15 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8186331
10 August 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7978494
10 August 2024 Administrative Inspection · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7979306
13 March 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7878282
30 November 2023 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7822599
2 February 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7630806
23 March 2022 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7417067
12 August 2021 Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7284477
16 March 2021 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 7158524
14 April 2020 Administrative Inspection · Initial Certification · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6938790
14 December 2016 Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6057573
9 September 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6075388
12 March 2014 Administration
Administrative · Commandant (CG-CVC) · Activity 4814719
25 February 2011 DAPI Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3953364
25 October 2009 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 3621463
15 November 2008 Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3363841
1 September 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3404104
8 July 2006 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 2706719
19 May 2006 Type not recorded
No type recorded · Violation Case Coordination Center · Activity 2653343
2 March 2006 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 2594533
2 March 2006 Uninspected Other · MTSA Verification · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2598078
1 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2595029
1 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2611679
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996464
25 July 2002 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1652314
22 February 2001 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1522370
5 November 1999 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1511212
14 October 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 762941
16 August 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 204112

Deficiency record · 37

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 July 2025 No resolution recorded
A towing vessel may not be operated without having onboard a valid COI issued by the CG. The vessel's COI expired on 14JUL2025. Vessel is prohibited from operating commercially until a COI inspection is completed to the satisfaction of an attending CG inspector.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 July 2025 No resolution recorded
A vessel that is exposed to salt water not more than 6 months in any 12 month period must undergo a dry dock and ISE at least once every 5 years. The vessel did not complete its dry dock and ISE by the due date of 14JUL2025. Vessel is prohibited from operating commercially until a dry dock and ISE is completed to the satisfaction of an attending CG inspector.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 August 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. 46 CFR 143.205(a) Vessel to demonstrate full functionality of main engine and generators prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2024
Resolved 12 August 2024
Resolution: Vessel identified cause of issue and will be towed to owners facility.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 November 2023 Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Request was submitted on November 8, 2023, past the deadline for an Annual Inspection, which was due within the 3 months before or after July 14, 2023. 46 CFR 137.200
Action required: 10 - Deficiency Rectified
Due 30 November 2023
Resolved 30 November 2023
Resolution: Conducted annual exam and issued a Letter of Warning
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 November 2023 Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Abandoned flange on the stbd side shell was found leaking. Conduct necessary repairs. 46 CFR 140.605(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2023
Resolved 22 December 2023
Resolution: Provided photographic evidence
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 November 2023 Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. A water line was leaking onto the stbd generator. Secure leak and conduct necessary repairs. 46 CFR 143.400(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2023
Resolved 22 December 2023
Resolution: Provided photographic evidence
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 30 November 2023 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Vessel had numerous watertight doors with inoperable closure devices. Repair. 46 CFR 140.610(b)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2023
Resolved 22 December 2023
Resolution: Provided photographic evidence
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 November 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI observed power strips in accommodation spaces being daisy chained. Remove power strips from outlets. 46 CFR 143.400(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2023
Resolved 22 December 2023
Resolution: Provided photographic evidence
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 November 2023 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Battery boxes in engine room were not secured and could move around the deck. Secure battery boxes. 46 CFR 143.400(e)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2023
Resolved 22 December 2023
Resolution: Provided photographic evidence
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2023 Resolved
A vessel must be operated in such a manner as to afford protection against hazards to life, property, and the environment. Water heater relief valve is directed towards a walkway, presenting a hazard to the crew. 46 CFR 140.205(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2023
Resolved 22 December 2023
Resolution: Provided photographic evidence
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 30 November 2023 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. MI Observed multiple first aid kits not appropriately sized. Obtain a kit appropriately sized to crew and operating conditions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2023
Resolved 22 December 2023
Resolution: Provided photographic evidence
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2023 Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. MI identified vessel did not have bridge to bridge certificate. Obtain valid certificate and endorsement for bridge to bridge. 47 CFR 80.1005
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2023
Resolved 22 December 2023
Resolution: Provided photographic evidence
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2023 Resolved
The current station authorization for a station other than a public coast station, or a clearly legible copy, must be posted at the principal control point of each station. MI identified vessel did not have a station license. Obtain and post station license on vessel. 47 CFR 80.405(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2023
Resolved 22 December 2023
Resolution: Provided photographic evidence
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 February 2023 Resolved
All fire-detection systems must be inspected or tested at least once every 12 months. Fire detection had not been serviced/inspected within the last 12 months. Service technician was observed inspecting and testing fire detection before inspection team's departure, deficiency rectified.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 February 2023
Resolution: Techs attended vessel and verified system function during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 February 2023 Resolved
Each lifebuoy on a towing vessel must be outfitted and mounted to the vessel in the manner described in the regulations. Lifebuoys were mounted in a manner in which they could not be deployed, had lines for the water light and lifeline tied incorrectly around another line instead of the body of the ring, had line which was not long enough for the water light, and the clips to remove the water light from the line were not large enough to allow for rapid removal. Correctly outfit and mount the lifebuoys per the regulations listed prior to vessel operation.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 14 February 2023
Resolved 15 February 2023
Resolution: O/O provided pictures showing the remounting of lifebouy and lights with proper connections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 February 2023 Resolved
Propulsion machinery, including main engines must be maintained to ensure proper operation and have a means to monitor and control the amount of thrust at each operating station. Starboard main engine was missing tachometer and leaking lube oil from area of missing component. Install tachometer on the Starboard main engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 1 April 2023
Resolution: Received photo evidence of satisfactory repair.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 February 2023 Resolved
Propulsion machinery, including main engines must be maintained to ensure proper operation and exposed hazards such as gears and rotating machinery must be protected by a cover, guard or rail. Rotating machinery on both ship service generators were missing. Install protective devices to minimize hazards to personnel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 3 March 2023
Resolution: Received photos demonstrating installation of guards intalled over moving parts.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 14 February 2023 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Panel in the wheel house was found with an unidentified breaker taped in the closed position. Remove unused breaker and replace with a blank or properly identify circuit if still in use.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 28 March 2023
Resolution: Breakers now properly labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2023 Resolved
The connections of flexible cable plugs and socket outlets must be designed to prevent unintended separation. Bilge pump near starboard main was found plugged in with the cord running over the top of the engine shaft in the bilge and did not have device preventing unintended separation. Reconfigure plug/cord configuration to ensure essential dewatering capability is not compromised.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 28 March 2023
Resolution: Portable bilge pump removed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 February 2023 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. First aid kit was missing items and expired as was the eye wash solution. Replace first aid kit with new and remove expired items from the vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 28 March 2023
Resolution: New First Aid kit installed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 14 February 2023 Resolved
All machinery and equipment that is not in proper working order must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. Marine Sanitation Device is wasted. Multiple open holes in the top of the sanitation tank due to corrosion were discovered negating the device's approval. Immediately take sanitation system out of service and and make device unusable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2023
Resolved 3 March 2023
Resolution: Taken out of service permanently.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 October 2021 Resolved
Records of drills and instruction must be maintained in the official log book. The record must include: The date of the drill. A description of the drill scenario and instruction topics. The personnel involved. Observed that the vessel is logging that a drill was conducted, but the log entry does not include the required information as per the CFR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 10 December 2021
Resolution: Inspected Drill procedures, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 October 2021 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Observed that multiple items in the First Aid kit and Blood borne Pathogens kit were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 25 October 2021
Resolution: Replaced with a new first aid kit. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 14 October 2021 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Observed that the vessel shares a laptop with chart software with another company vessel. The laptop was not onboard at the onset of the inspection. The vessel had only uncorrected paper charts onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 30 November 2021
Resolution: laptop with rosepoint installed, all charts and pubs replaced with new as backup.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 October 2021 Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. Observed that the operating station lifejacket did not have a light attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 25 October 2021
Resolution: Replaced light on lifejacket, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 October 2021 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. Observed that the smoke detector in the port berthing room had a dead battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 25 October 2021
Resolution: Replaced smoke detector, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 14 October 2021 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to the crew. Observed that the hand rail at the top of the pilot house deck latter was cut and not re-welded leaving the railing not of adequate strength.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 10 December 2021
Resolution: Hand rail has been welded, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 14 October 2021 Resolved
Towing machinery must have sufficient safeguards. Deck winch guard covers were observed to have been rusted through and require replacing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 30 November 2021
Resolution: Guards were replaced, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 October 2021 Resolved
Emergency engine room lighting was inoperable. Emergency lighting must be provided for all internal crew working areas.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 30 November 2021
Resolution: Engine room emergency lighting was replaced and tested, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 October 2021 Resolved
No RPM gauges were observed at the operating station or the engine room for the main diesel engines. In addition, the lubricating oil gauge on the port main diesel engine was not functioning properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 30 November 2021
Resolution: Installed RPM gauges in the engine room and wheelhouse, replaced L/O gauge on port engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2021 Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. Vessel records were not kept up, maintenance plan has not been followed for over 6 mos. Update maintenance plan to the satisfaction of CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 30 November 2021
Resolution: Maintenance plan logs and records in good order, all sat.
Fire Fighting › Fire Pumps › Location
Issued 2 March 2006 Resolved
Install fire pump IAW 46 CFR 27.301
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 28 March 2006
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Location
Issued 2 March 2006 Resolved
Install fire-extinguishing equipment IAW 46CFR27.303
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 28 March 2006
Navigation › Piloting/Steering › Marine Charts
Issued 2 March 2006 Resolved
Prove correct marine charts on board IAW 46CFR26.03-4
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 28 March 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 March 2006 Resolved
Prove current Light List ISW 46CFR26.03-4
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 28 March 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 2 March 2006 Resolved
Prove tide tables on board IAW 46CFR26.03-4
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 28 March 2006
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 2 March 2006 Resolved
Prove installation of sanitation device or holding tank IAW 33CFR159.7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 28 March 2006

Recorded names · 1

BARBARA S BADEAUX (2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record