Records from 2001 to 2024. Most recent: inspection, 16 October 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 October 2024
No resolution recorded
As a result of Hurricane MILTON, the REEF RAIDER broke free from its mooring location and drifted into the mangroves hard aground. Vessel is required to undergo a satisfactory hull exam to ensure structural/watertight integrity prior the carriage of passengers.
46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 May 2021
Resolved
Prior to carrying passengers, prove proper operation of Fireboy engine shutdown for both port and starboard engines to the satisfaction of a Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2021
Resolved 19 May 2021
Resolution: Received video of engine cut off functioning from the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 May 2021
Resolved
01 15 person lifefloat condemned. Passenger count reduced to 28 with 02 crew for a total of no more than 30 persons for a LBS plus LCW route in warm waters.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 2 August 2022
Resolution: Passenger count was reduced and owner opted to not replace lifefloat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 May 2021
Resolved
Emergency fuel shut off for port fuel tank does not close completely. Prove proper operation to the satisfaction of a Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 17 June 2021
Resolution: Witnessed operation of fuel shut off valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 May 2021
Resolved
Prove proper operation of the starboard engine shutdown from the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 21 May 2021
Resolution: Received video of starboard engine shutdown functioning from the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2021
Resolved
04 adult lifejackets condemned. Total persons onboard reduced to 48.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 17 June 2021
Resolution: New jackets onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2021
Resolved
Remove dead end wires in lazarette and under helm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 17 June 2021
Resolution: Wires removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2021
Resolved
Replace wasted fire extinguisher bracket in main deck starboard side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 17 June 2021
Resolution: New bracket for fire extinguisher installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2021
Resolved
Raise electrical wires running along bilge from port engine to starter bus.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 17 June 2021
Resolution: Wires re-routed above bilge.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 17 May 2021
Resolved
Replace rotten/wasted longitudinal frame in overhead starboard side IWO fwd buklhead in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 19 June 2021
Resolution: Received pictures of new frame.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2021
Resolved
Properly secure battery under helm to deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 17 June 2021
Resolution: Battery properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 May 2021
Resolved
Proivde and post lifejacket donning instructions.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 18 May 2021
Resolution: Received photo of placard posted in accomodation area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 May 2021
Resolved
Relabel emergency fuel shut off marking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 19 May 2021
Resolution: Received photo of relabeled emergency fuel shutoff markings.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 May 2021
Resolved
Provide current coast pilot, tide table, and light list.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 17 June 2021
Resolution: New publications onboard.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 May 2020
Resolved
Vessel's nautical publications are all out of date. Provide proof of purchase and outfitting with new up to date publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2020
Resolved 8 June 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 May 2020
Resolved
Replace overhead transverse frames in overhead along centerline as well as all frames around watertight hatch for the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 10 June 2020
Resolution: Wasted wood replaced with new wood.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 12 June 2018
Resolved
The port and starboard rudderpost stuffing boxes were leaking excessively. The shaft tubes of the port and starboard propeller were also leaking excessively. They were all tighten and leaking stopped with the exemption of the stuffing box of the portside rudder shaft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2018
Resolved 11 July 2018
Resolution: Re-packed port rudder, no longer leaking.
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 June 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 12 July 2018
Resolved 14 June 2018
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 June 2018
Resolved
Lifesaving equipment maintainance log missing
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2018
Resolved 11 July 2018
Resolution: Started lifesaving log.
Lifesaving › Hand Flares › Not on Board
Issued 12 June 2018
Resolved
missing 4 Flares
Due 12 July 2018
Resolved 14 June 2018
Lifesaving › Lifefloat › Markings
Issued 12 June 2018
Resolved
Life float is cracked and and missing vessel marking
Due 12 July 2018
Resolved 28 June 2018
Resolution: Lifefloat markings and shell renewed.
Communications › Radio Communications › EPIRB
Issued 24 April 2017
Resolved
EPIRB battery is expired. Replace, or puruchase new EPIRB. Do not cross demarcation line until replaced.
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 19 May 2017
Resolution: New EPIRB purchased.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 April 2017
Resolved
Vessel does not have a mast head light. Do not operate after sunset until a proper 225 degree light is installed with a 3 mile visibility.
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 19 May 2017
Resolution: Mast head light purchased and installed.
Lifesaving › Lifefloat › Float-free Link
Issued 9 August 2016
Resolved
Weak link on life floats cannot be verified, purchase proper link for number of people floats are certified to carry.
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 10 August 2016
Resolution: Vessel rep emailed weak link photo documentation of required breaking strength and installation.
Lifesaving › Lifefloat › Lifeline
Issued 9 August 2016
Resolved
Repair two attachments on life float for the grab line.
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 6 September 2016
Resolution: Repaired attachments for grab lines.
Engineering › Fuel Oil Service System › Valve
Issued 9 August 2016
Resolved
Starboard fuel shut off cable broke.
Due 23 August 2016
Resolved 9 August 2016
Resolution: Cable replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 August 2016
Resolved
Lifesaving line is 50', make it 60'.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 9 August 2016
Resolution: New line fitted.
Documentation › Certificates/Documents › Stability Letter
Issued 9 August 2016
Resolved
Stability letter is not posted on board, make available.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 6 September 2016
Resolution: Posted stability letter
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 August 2016
Resolved
Make first aid kid updated.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 6 September 2016
Resolution: Purchased new first aid kit
Operations/Management › Drills/Instruction › Fire
Issued 9 August 2016
Resolved
Provide emergency instruction list on board and post.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 9 August 2016
Resolution: Posted instruction list.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 August 2016
Resolved
Vessel has not had annual exam within 3 months of due date, do not carry passengers until annual exam is complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 August 2016
Resolution: Completed annual exam.
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2016
Resolved
Make permanent repairs to all areas indentified on exterior hull during inspection. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 May 2016
Resolution: Verified all areas were repaired on exterior of hull. Repaired by grinding to dry fiberglass and repaired with resin & fiberglass.
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2016
Resolved
Make permanent repairs to all areas identified on main deck and pilothouse deck. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 June 2016
Resolution: Removed decayed wood in areas identified, replaced with new wood and fiberglassed over. Main deck/pilothouse 3'high x 4'wide & stbd side pilothouse 4' high x 5' high.
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 May 2016
Resolved
Remove all wood furring on overhead above starboard engine and preserve. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: Verified at annual inspection.
Construction/Loadline › Structures › Manhole
Issued 9 May 2016
Resolved
Make permanent repairs to forcastle where manhole cover is located,bulkhead is decayed. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: Verified at annual inspection.
Construction/Loadline › Structures › Superstructure
Issued 9 May 2016
Resolved
Make permanent repairs to forward pilothouse sheathing that is decayed. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: Verified at annual inspection.
Construction/Loadline › Structures › Superstructure
Issued 9 May 2016
Resolved
Make permanent repairs to starboard side upper pilot house. Starboard side sheathing where window is located is decayed the length of window. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 June 2016
Resolution: Removed decayed wood stbd side upper pilothouse. Replaced with new marine grade plywood & fiberglassed over 4'high x 5' wide.
Construction/Loadline › Structures › Cofferdam
Issued 9 May 2016
Resolved
Remove all identified decayed wood in voids #2 & #3 and replace with new to original. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: Verified at annual inspection.
Construction/Loadline › Structures › Superstructure
Issued 9 May 2016
Resolved
Provide plan proposal for interior pilothouse maindeck overhead repairs. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: Verified at annual inspection.
Construction/Loadline › Hull › Hull Plating
Issued 15 May 2014
Resolved
Repair main deck starboard side aft main deck 2' -3' section near livewel that is spongy.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 1 June 2015
Construction/Loadline › Structures › Superstructure
Issued 15 May 2014
Resolved
Repair areas identified on walkway around pilothouse and install non-skid.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 August 2014
Resolved 1 June 2015
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 March 2014
Resolved
Vessel's CG light list was not up to date for area of operation. Provide an updated CG light list for area of operations. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2014
Resolved 27 March 2014
Resolution: Vessel provided an updated version of the CG Light List for area of operation.
Lifesaving › Lifefloat › Lifeline
Issued 25 March 2014
Resolved
Life lines on both life floats are severly deteriorated. Replace all life lines on both life floats. 46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2014
Resolution: Vessel replaced all lines identified on both life floats identified.
Lifesaving › Lifefloat › Serviceable
Issued 25 March 2014
Resolved
Both life floats were noted with damage that needed to be repaired. Repair the indentified areas on both life floats for repair. 46 CFR 185.700
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 April 2014
Resolved 2 April 2014
Resolution: Recieved pictures of repairs using [name withheld] repair kit. SAT
Lifesaving › Lifebuoys › Serviceable
Issued 25 March 2014
Resolved
Vessel's ring buoy's retro reflective tape is worn and deteriorated. Replace retro reflective material or renew ring buoy with new. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2014
Resolved 2 April 2014
Resolution: Recieved pictures showing replacement of reflective tape on the ring life buoy. SAT
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 25 March 2014
Resolved
Vessel's port main diesel engine exhaust is missing a hose clamp. Install hose clamp. 46 CFR 182.720(e)((3)(B)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2014
Resolved 27 March 2014
Resolution: Vessel installed new hose clamp on that was identified on the port main diesel engine.
Electrical › Electric Supply System (service) › Cable
Issued 25 March 2014
Resolved
Vessel had multiple battery cables that are very worn and loose identified during inspection. Replace cables. 46 CFR 183.05-20
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2014
Resolution: Vessel replaced identified cabling with new.
Electrical › Electric Supply System (service) › Cable
Issued 25 March 2014
Resolved
Identified multiple battery cables on both port and starboard main diesel engines battery banks that were loose. Tighten all battery cables identified. 46 CFR 183.05-20
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2014
Resolution: Vessel tightened all cables identified on both main diesel engines.
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 March 2014
Resolved
Re-stencil emergency fuel shut-offs, stenciling is faded. 46 CFR 185.30-20
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2014
Resolved 27 March 2014
Resolution: Vessel re-stenciled emergency fuel shut-offs.
Construction/Loadline › Structures › Deck Plating
Issued 25 March 2014
Resolved
Indentified numerous areas both port and starboard sides of main deck were passengers enter into common area that were spongy. Indentified areas on second deck around pilot house that need replacement. All items will be repaired or replaced prior to leaving dry dock in May 2014. 46 CFR 176.25-5
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 May 2014
Resolved 1 June 2015
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 25 March 2014
Resolved
Found starboard exhaust fiberglass through bulkhead fitting from the engineroom to the aft steering lazarette has crack in it. Crack is approximately 4" back from forward steering lazarette bulkhead and going around pipe approximately 5". Repair crack. 46 CFR 176.25-10
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2014
Resolution: Vessel repaired crack by have fiberglass permanent repair be conducted. Tested exhaust all SAT.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 March 2014
Resolved
Vessel's Certificate of Inspection and Stability Letters were damaged by water to the extent they were unreadable. Replace/Post COI and Stability Letters. 46 CFR 176.01
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2014
Resolved 27 March 2014
Resolution: Vessel made copy of COI and Stability Letter and posted.
Navigation › Piloting/Steering › Marine Charts
Issued 19 June 2012
Resolved
Provide on board a current nautical chart IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 25 June 2012
Construction/Loadline › Structures › Manhole
Issued 19 June 2012
Resolved
Replace in kind watertight hatch between engine room and forward compartment IAW 46 CFR 179.320.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2012
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 June 2012
Resolved
Replace 03 waterlight batteries on board with ones recommended by manufacturer IAW 46 CFR 180.70(d)(1). Vessel restricted to daytime only.
Action required: 705 - Other - as specified
Due 28 June 2012
Resolved 5 July 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 June 2012
Resolved
Replace expired items in first aid kit IAW 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 25 June 2012
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 19 June 2012
Resolved
Provide copy of MIS report and EAP training IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 25 June 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 April 2009
Resolved
Repair anchor light.
Due 10 April 2009
Resolved 10 April 2009
Fire Fighting › Fire Bucket › Availability
Issued 9 April 2009
Resolved
Replace (3) fire buckets
Due 15 April 2009
Resolved 9 April 2009
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 9 April 2009
Resolved
Repair leak on both engine exhaust piping.
Due 15 April 2009
Resolved 10 April 2009
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 18 June 2008
Resolved
Provide proof of serious marine incident drug test kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Personnel › Certificates/Documents/Licenses › License, Master
Issued 18 June 2008
Resolved
Provide original Coast Guard operators license.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 June 2008
Resolved
Provide servicing report fixed fire extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Lifesaving › Hand Flares › Quantity
Issued 18 June 2008
Resolved
Provide six red flares
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Communications › Public Address System › Announcing Station
Issued 18 June 2008
Resolved
Repair PA system and prove proper operation
Due 26 June 2008
Resolved 24 June 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 June 2008
Resolved
Install rail course at port aft gate
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 June 2008
Resolved
Replace expired items in first aid kit
Due 26 June 2008
Resolved 24 June 2008
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 18 June 2008
Resolved
Install two smoke detectors on vessel
Due 26 June 2008
Resolved 24 June 2008
Engineering › Bilge Water Management System › Pump
Issued 18 June 2008
Resolved
Pump after steering compartment dry and replace gasket on water tight hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 18 June 2008
Resolved
Remove unprotected portable lights in engine room
Due 18 June 2008
Resolved 18 June 2008
Electrical › Electrical Distribution System (service) › Switch
Issued 18 June 2008
Resolved
Mark all switches at operating stations on bridge
Due 26 June 2008
Resolved 24 June 2008
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 18 June 2008
Resolved
Install window wiper bridge
Due 26 June 2008
Resolved 24 June 2008
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 18 June 2008
Resolved
Properly secure spare anchor.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 June 2008
Resolved
Repair water leaks from intruding into main cabin replace wood deck on 2 deck port side.
Due 26 June 2008
Resolved 3 July 2008
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2007
Resolved
PROVIDE CURRENT DRUG CONSORTIUM CONTRACT
Action required: 705 - Other - as specified
Resolved 28 May 2007
Resolution: CLEARED
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 15 May 2007
Resolved
PROVIDE SERVICING REPORT FOR FIRE EXTINGUISHERS
Action required: 705 - Other - as specified
Resolved 28 May 2007
Resolution: CLEARED
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 May 2007
Resolved
REFRESH ALL EXPIRED ITEMS IN THE FIRST AID KIT.
Action required: 705 - Other - as specified
Resolved 28 May 2007
Resolution: CLEARED
Documentation › Certificates/Documents › FCC SSL
Issued 15 May 2007
Resolved
PROVIDE CURRENT FCC SAFETY RADIO TELEPHONY CERTIFICATE.
Action required: 705 - Other - as specified
Resolved 11 June 2007
Resolution: CLEARED
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2007
Resolved
REMOVE DEAD END WIRING IN THE ENGINE SPACE.
Action required: 705 - Other - as specified
Resolved 11 June 2007
Resolution: CLEARED
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2007
Resolved
REMOVE DEAD END WIRING UNDER THE OPERATORS CONSOLE
Action required: 705 - Other - as specified
Resolved 11 June 2007
Resolution: CLEARED
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 15 May 2007
Resolved
SECURE EXCESSIVE DRIPPING FROM THE PORT SHAFT PACKING.
Action required: 705 - Other - as specified
Due 15 May 2007
Resolved 15 May 2007
Resolution: CLEARED
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 May 2007
Resolved
VESSEL REDUCED TO 44 PASSENGERS UNTIL FULL COMPLEMENT OF LIFEJACKETS ARE ONBOARD.
Action required: 705 - Other - as specified
Resolved 28 May 2007
Resolution: CLEARED
Engineering › Shafting/Propeller Arrangements › Thrust Bearing
Issued 1 June 2006
Resolved
Tighten both port and STBD shaft packing glands prior to the carriage of passengers.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 2 June 2006
Resolution: Cleared
Documentation › Logs/Records › Drug Test Records
Issued 1 June 2006
Resolved
Fax a copy of the 2005 MIS report to MSD Fort Myers.
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 1 June 2006
Resolution: Cleared
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 1 June 2006
Resolved
Provide a fax copy of the fixed fire extinguishers system servicing report to MSD Fort Myers.
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 1 June 2006
Resolution: Cleared
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 March 2006
Resolved
Crop and renew transverse frame identified during inspection.
Action required: 705 - Other - as specified
Due 22 April 2006
Resolved 8 May 2006
Construction/Loadline › Hull › Hull Plating
Issued 22 March 2006
Resolved
Clean out and make accessible forepeak area.
Action required: 705 - Other - as specified
Due 22 April 2006
Resolved 8 May 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 22 March 2006
Resolved
Properly support both STBD and port mufflers and ensure that all connection in space have double clamps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2006
Resolved 22 March 2006
Resolution: Cleared.
Construction/Loadline › Hull › Keel
Issued 22 March 2006
Resolved
Re-glass aft end of skeg.
Action required: 705 - Other - as specified
Due 22 April 2006
Resolved 8 May 2006
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 17 May 2005
Resolved
APPLY NEW RETRO TAPE TO LIFEFLOATS.
Due 17 June 2005
Resolved 6 October 2005
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 17 May 2005
Resolved
RE-CLAMP STARBOARD SHAFT STUFFING BOX.
Due 17 June 2005
Resolved 6 October 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 17 May 2005
Resolved
PROPERLY SUPPORT MUFFLERS.
Due 17 June 2005
Resolved 6 October 2005
Documentation › Safety/Response Plans/Programs
Issued 24 March 2004
Resolved
PROVIDE ONBOARD A WASTE MANAGEMENT PLAN AS PER 33CFR151.57. LEGACY COMPONENT DESC: Waste Management Plan
Due 24 April 2004
Resolved 8 April 2004
Navigation › Collision/Grounding Avoidance
Issued 24 March 2004
Resolved
REPAIR STARBOARD RUNNING LIGHT AND PROVIDE A STERN LIGHT AS PER COLREGS. LEGACY COMPONENT DESC: Navigation Lights
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Communications › Audible Communications
Issued 24 March 2004
Resolved
PROVIDE A HORN ONBOARD VESSEL AS PER 33CFR PART 86. LEGACY COMPONENT DESC: Horn/Whistle
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Communications › Radio Communications
Issued 24 March 2004
Resolved
PROVIDE A CURRENT EPIRB HYDROSTATIC RELEASE ONBOARD AS PER 46CFR180.64. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 24 March 2004
Resolved
PROVIDE AN ADDITIONAL 5 ADULT TYPE I PFDs ONBOARD VESSEL AS PER 46CFR180.71. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 March 2004
Resolved
PROVIDE A COMPLETE FIRST AID KIT ONBOARD AS PER 46CFR184.710. LEGACY COMPONENT DESC: Medicine Chest
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 March 2004
Resolved
DE-RUST AND PAINT BOTTOMS OF ALL PORTABLE FIRE EXTINGUISHERS AS PER 46CFR176.810. LEGACY COMPONENT DESC: Condition
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 24 March 2004
Resolved
PROVIDE A GROUND WIRE FROM TOP OF FUEL FILL FLANGE TO FUEL TANK AS PER 46CFR182.445(G) ON BOTH TANKS. LEGACY COMPONENT DESC: Flange
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Electrical › Electric Supply System (service)
Issued 24 March 2004
Resolved
REMOVE CORROSION FROM MAIN BATTERY TERMINALS AS PER 46CFR183.350. LEGACY COMPONENT DESC: Battery Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Electrical › Electrical Distribution System (service)
Issued 24 March 2004
Resolved
REMOVE DEAD END/UNUSED WIRING IN ENGINEROOM NEAR SEWAGE HOLDING TANK. LEGACY COMPONENT DESC: Wiring
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Electrical › Electric Supply System (service)
Issued 24 March 2004
Resolved
PROVIDE A COVER FOR SMALL BATTERY BOX NEAR SEWAGE HOLDING TANK OR REMOVE FROM VESSEL IF UNUSED AS PER 46CFR183.350. LEGACY COMPONENT DESC: Battery Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Engineering › Sea-water System (primary cooling)
Issued 24 March 2004
Resolved
PROVIDE A PERMANENT TYPE CAP FOR THE UNUSED SEA VALVE IN WAY OF THE STARBOARD SIDE OF THE ENGINEROOM. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Fire Fighting › Structural Fire Protection - General
Issued 24 March 2004
Resolved
RE-ATTACH LOOSE SHEET METAL IN WAY OF ENGINEROOM OVERHEAD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Fire Fighting › Combustible Materials
Issued 24 March 2004
Resolved
REMOVE FLAMMABLE LIQUID CONTAINERS AND REPAIR DEBRIS FROM DRYDOCK REPAIRS IN WAY OF ENGINEROOM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Engineering › Bilge Water Management System
Issued 24 March 2004
Resolved
ATTACH BILGE PUMP SECURELY TO ENGINEROOM BILGE FORWARD. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Documentation › Markings/Placards
Issued 24 March 2004
Resolved
STENCIL "REMOTE FUEL SHUTOFF" AT STERN DECK HATCH AS PER 46CFR185.608.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 24 March 2004
Resolved
SECURELY MOUNT REMOTE FUEL SHUTOFF VALVES. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Documentation › Markings/Placards
Issued 24 March 2004
Resolved
STENCIL PYROTECHNIC STORAGE BOX "DISTRESS SIGNALS" AS PER 46CFR185.614.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2004
Resolved
PROVIDE GRAB RAILS FOR PORT SIDE OF WHEELHOUSE AND APPLY NON-SKID TO SAME AREA AS PER 46CFR177.900(C). LEGACY COMPONENT DESC: Hand Grab
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Deck/Cargo › Mooring/Anchoring
Issued 24 March 2004
Resolved
SECURE MOORING SAMPSON POST ON STARBOARD SIDE TO THE DECK.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Lifesaving › Lifejacket/PFD (General)
Issued 24 March 2004
Resolved
PROPERLY MARK LIFEJACKET STOWAGE LOCKERS WITH QUANTITY AND TYPE OF PFDs ENCLOSED AS PER 46CFR185.604(F). LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Documentation › Certificates/Documents
Issued 24 March 2004
Resolved
PROVIDE A VALID STATE REGISTRATION FOR THE VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Accommodation/Occupational Safety › Washroom/Toilet
Issued 24 March 2004
Resolved
PROPERLY MOUNT TOILET IN HEAD TO PREVENT PASSENGER INJURY. LEGACY COMPONENT DESC: Toilet
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2004
Resolved 8 April 2004
Construction/Loadline › Hull
Issued 29 January 2004
Resolved
REPAIR ALL DELAMINATED AREAS IN WAY OF PORT AND STARBOARD SPRAYRAILS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2004
Resolved 13 February 2004
Engineering › Shafting/Propeller Arrangements
Issued 29 January 2004
Resolved
RENEW ALL CUTLASS BEARINGS. LEGACY COMPONENT DESC: Strut Bearing
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2004
Resolved 13 February 2004
Engineering › Shafting/Propeller Arrangements
Issued 29 January 2004
Resolved
RENEW OR REPAIR PORT AND STARBOARD PROPELLER SHAFTS. LEGACY COMPONENT DESC: Propeller Shaft
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2004
Resolved 13 February 2004
Engineering › Sea-water System (primary cooling)
Issued 29 January 2004
Resolved
RENEW WASTED 1/2" SEA VALVE. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2004
Resolved 13 February 2004
Construction/Loadline › Hull
Issued 29 January 2004
Resolved
PROPERLY REPAIR STARBOARD OUTBOARD LONGITUDINAL /ENGINE BED FRAMEJUST AFT OF STBD ENGINE. LEGACY COMPONENT DESC: Longitudinal Frame
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2004
Resolved 13 February 2004
Construction/Loadline › Structures
Issued 29 January 2004
Resolved
REPAIR ALL SOFT AREAS NOTED ON MAIN DECK. LEGACY COMPONENT DESC: Deck Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2004
Resolved 24 March 2004
Construction/Loadline › Structures
Issued 29 January 2004
Resolved
PROVIDE ACCESS TO VOID FORWARD OF COLLISION BULKHEAD. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2004
Resolved 24 March 2004
Engineering › Bilge Water Management System
Issued 23 January 2003
Resolved
Repair AFT void bilge high level alarm. LEGACY COMPONENT DESC: Alarm
Condition: Improper/Lack of Maintenance
Due 24 January 2003
Resolved 24 January 2003
Fire Fighting › Miscellaneous Items
Issued 23 January 2003
Resolved
Prior to the carriage of passengers, replace batteries in both smoke detectors. LEGACY COMPONENT DESC: Smoke Detector
Condition: Improper/Lack of Maintenance
Due 23 January 2003
Resolved 24 January 2003