Inspection history · 17
16 October 2024
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8019781
1 May 2024
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7903906
14 March 2024
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7876004
10 May 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7684586
1 December 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7602772
24 June 2022
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7480060
17 May 2022
Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7452119
17 May 2021
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7196711
29 May 2020
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6961514
5 May 2020
Administrative Inspection · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6947884
19 February 2019
COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6628046
12 June 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6440744
2 May 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6403087
24 April 2017
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6131153
7 September 2016
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5994341
2 August 2016
Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5961198
9 May 2016
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5857565
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 October 2024
No resolution recorded
As a result of Hurricane MILTON, the REEF RAIDER broke free from its mooring location and drifted into the mangroves hard aground. Vessel is required to undergo a satisfactory hull exam to ensure structural/watertight integrity prior the carriage of passengers.
46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 May 2021
Resolved
Prior to carrying passengers, prove proper operation of Fireboy engine shutdown for both port and starboard engines to the satisfaction of a Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2021
Resolved 19 May 2021
Resolution: Received video of engine cut off functioning from the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 May 2021
Resolved
01 15 person lifefloat condemned. Passenger count reduced to 28 with 02 crew for a total of no more than 30 persons for a LBS plus LCW route in warm waters.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 2 August 2022
Resolution: Passenger count was reduced and owner opted to not replace lifefloat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 May 2021
Resolved
Emergency fuel shut off for port fuel tank does not close completely. Prove proper operation to the satisfaction of a Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 17 June 2021
Resolution: Witnessed operation of fuel shut off valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 May 2021
Resolved
Prove proper operation of the starboard engine shutdown from the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 21 May 2021
Resolution: Received video of starboard engine shutdown functioning from the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2021
Resolved
04 adult lifejackets condemned. Total persons onboard reduced to 48.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 17 June 2021
Resolution: New jackets onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2021
Resolved
Remove dead end wires in lazarette and under helm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 17 June 2021
Resolution: Wires removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2021
Resolved
Replace wasted fire extinguisher bracket in main deck starboard side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 17 June 2021
Resolution: New bracket for fire extinguisher installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2021
Resolved
Raise electrical wires running along bilge from port engine to starter bus.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 17 June 2021
Resolution: Wires re-routed above bilge.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 17 May 2021
Resolved
Replace rotten/wasted longitudinal frame in overhead starboard side IWO fwd buklhead in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 19 June 2021
Resolution: Received pictures of new frame.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2021
Resolved
Properly secure battery under helm to deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 17 June 2021
Resolution: Battery properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 May 2021
Resolved
Proivde and post lifejacket donning instructions.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 18 May 2021
Resolution: Received photo of placard posted in accomodation area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 May 2021
Resolved
Relabel emergency fuel shut off marking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 19 May 2021
Resolution: Received photo of relabeled emergency fuel shutoff markings.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 May 2021
Resolved
Provide current coast pilot, tide table, and light list.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 17 June 2021
Resolution: New publications onboard.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 May 2020
Resolved
Vessel's nautical publications are all out of date. Provide proof of purchase and outfitting with new up to date publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2020
Resolved 8 June 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 May 2020
Resolved
Replace overhead transverse frames in overhead along centerline as well as all frames around watertight hatch for the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 10 June 2020
Resolution: Wasted wood replaced with new wood.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 12 June 2018
Resolved
The port and starboard rudderpost stuffing boxes were leaking excessively. The shaft tubes of the port and starboard propeller were also leaking excessively. They were all tighten and leaking stopped with the exemption of the stuffing box of the portside rudder shaft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2018
Resolved 11 July 2018
Resolution: Re-packed port rudder, no longer leaking.
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 June 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 12 July 2018
Resolved 14 June 2018
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 June 2018
Resolved
Lifesaving equipment maintainance log missing
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2018
Resolved 11 July 2018
Resolution: Started lifesaving log.
Lifesaving › Hand Flares › Not on Board
Issued 12 June 2018
Resolved
missing 4 Flares
Due 12 July 2018
Resolved 14 June 2018
Lifesaving › Lifefloat › Markings
Issued 12 June 2018
Resolved
Life float is cracked and and missing vessel marking
Due 12 July 2018
Resolved 28 June 2018
Resolution: Lifefloat markings and shell renewed.
Communications › Radio Communications › EPIRB
Issued 24 April 2017
Resolved
EPIRB battery is expired. Replace, or puruchase new EPIRB. Do not cross demarcation line until replaced.
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 19 May 2017
Resolution: New EPIRB purchased.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 April 2017
Resolved
Vessel does not have a mast head light. Do not operate after sunset until a proper 225 degree light is installed with a 3 mile visibility.
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 19 May 2017
Resolution: Mast head light purchased and installed.
Lifesaving › Lifefloat › Float-free Link
Issued 9 August 2016
Resolved
Weak link on life floats cannot be verified, purchase proper link for number of people floats are certified to carry.
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 10 August 2016
Resolution: Vessel rep emailed weak link photo documentation of required breaking strength and installation.
Lifesaving › Lifefloat › Lifeline
Issued 9 August 2016
Resolved
Repair two attachments on life float for the grab line.
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 6 September 2016
Resolution: Repaired attachments for grab lines.
Engineering › Fuel Oil Service System › Valve
Issued 9 August 2016
Resolved
Starboard fuel shut off cable broke.
Due 23 August 2016
Resolved 9 August 2016
Resolution: Cable replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 August 2016
Resolved
Lifesaving line is 50', make it 60'.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 9 August 2016
Resolution: New line fitted.
Documentation › Certificates/Documents › Stability Letter
Issued 9 August 2016
Resolved
Stability letter is not posted on board, make available.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 6 September 2016
Resolution: Posted stability letter
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 August 2016
Resolved
Make first aid kid updated.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 6 September 2016
Resolution: Purchased new first aid kit
Operations/Management › Drills/Instruction › Fire
Issued 9 August 2016
Resolved
Provide emergency instruction list on board and post.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 9 August 2016
Resolution: Posted instruction list.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 August 2016
Resolved
Vessel has not had annual exam within 3 months of due date, do not carry passengers until annual exam is complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 August 2016
Resolution: Completed annual exam.
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2016
Resolved
Make permanent repairs to all areas indentified on exterior hull during inspection. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 May 2016
Resolution: Verified all areas were repaired on exterior of hull. Repaired by grinding to dry fiberglass and repaired with resin & fiberglass.
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2016
Resolved
Make permanent repairs to all areas identified on main deck and pilothouse deck. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 June 2016
Resolution: Removed decayed wood in areas identified, replaced with new wood and fiberglassed over. Main deck/pilothouse 3'high x 4'wide & stbd side pilothouse 4' high x 5' high.
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 May 2016
Resolved
Remove all wood furring on overhead above starboard engine and preserve. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: Verified at annual inspection.
Construction/Loadline › Structures › Manhole
Issued 9 May 2016
Resolved
Make permanent repairs to forcastle where manhole cover is located,bulkhead is decayed. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: Verified at annual inspection.
Construction/Loadline › Structures › Superstructure
Issued 9 May 2016
Resolved
Make permanent repairs to forward pilothouse sheathing that is decayed. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: Verified at annual inspection.
Construction/Loadline › Structures › Superstructure
Issued 9 May 2016
Resolved
Make permanent repairs to starboard side upper pilot house. Starboard side sheathing where window is located is decayed the length of window. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 June 2016
Resolution: Removed decayed wood stbd side upper pilothouse. Replaced with new marine grade plywood & fiberglassed over 4'high x 5' wide.
Construction/Loadline › Structures › Cofferdam
Issued 9 May 2016
Resolved
Remove all identified decayed wood in voids #2 & #3 and replace with new to original. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: Verified at annual inspection.
Construction/Loadline › Structures › Superstructure
Issued 9 May 2016
Resolved
Provide plan proposal for interior pilothouse maindeck overhead repairs. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: Verified at annual inspection.