CHEMROAD HAYA
CHEMROAD HAYA is a tank ship. The Coast Guard has recorded 1 inspection in 2026, along with 1 deficiency.
Records in 2026. Most recent: inspection, 2 June 2026.
- Built
- Not recorded
- Last inspected
- 2 June 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 1 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
Years with a record
1 calendar year (2026)
The 1 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it20117 - Convention (Subpart B), Gross Ton
33916 - Dead Weight, Ton
41771 - Displacement, Ton
9182 - Convention (Subpart B), Net Ton
33916 - Dead Weight, Ton
41771 - Displacement, Ton
9182 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 1
2 June 2026
PSC A · Deficiency Check · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8387271
Deficiency record · 1
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 9 June 2026
Resolved
For tankers of 20,000 tonnes deadweight and upwards, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirementes of the Fire Safety Systems Code...
The system shall be capable of delivering inert gas with an oxygen content of not more than 5% by volume in the inert gas supply main to the cargo tanks at any required rate of flow.
PSCO observed inert gas system cound not produce 5% or less oxygen.
74SOLAS(09CONS.) CH.II-2/5.5.1.1
FSS CODE 2007 CH.15/2.2.1.3