SANTORINI is a mobile offshore drilling unit. The Coast Guard has recorded 2 inspections since 2022, most recently in May 2023, along with 2 deficiencies.
Records from 2022 to 2023. Most recent: inspection, 18 May 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
18 May 2023Administrative Inspection · Deficiency Check · COC-MODU Renew
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7710840
25 February 2022ISPS Exam · Ballast Water Examination · COC-MODU Renew
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7385010
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 7 June 2023Resolved
Personal equipment shall consist of the following: protective clothing of material to protect the skin from heat radiating 1from the fire and from burns and scalding by steam. The outer surface shall be water resistant. Inspectors noted that no firefighting ensembles were provided with flash hoods to suitably protect the neck and face.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 16 June 2023
Resolution: Received photographs of 12 new firehoods for firefighting ensembles
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 June 2023Resolved
Self-closing doors in fire rated bulkheads shall not be fitted with hold-back hooks. Self-closing doors at laundry room and gymnasium had hold backs.
Deficiency cleared on the spot
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 7 July 2023
Resolved 7 July 2023