← All vessels

HARRY S

HARRY S is a 2022 industrial vessel. The Coast Guard has recorded 6 inspections since 2021, most recently in July 2025, along with 7 deficiencies.

Records from 2021 to 2025. Most recent: inspection, 25 July 2025.

Built
2022
Last inspected
25 July 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1712715
Flag
UNITED STATES
Maury page id
psix-1712715

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (2021–2025)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)210.8 ft × 65.0 ft × 13.8 ft
Registered tonnagegross 1,937 / net 1,937
ITC dimensions (L × B × D)210.8 ft × 65.0 ft × 13.8 ft
ITC tonnagegross 1,639 / net 491
BuilderCONRAD SHIPYARD LLC · AMELIA, LA, UNITED STATES · built 2022
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 May 2026 · expires 30 June 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1639 - Convention (Subpart B), Gross Ton
491 - Convention (Subpart B), Net Ton
1937 - Regulatory (Subpart C or D), Gross Ton
1937 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 6

25 July 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8194614
25 June 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8150322
4 September 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7996224
12 July 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7741502
28 October 2022 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7644233
21 July 2021 In-Service Inspection · COI Inspection · Construction Oversight · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7476786

Deficiency record · 7

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2025 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Drawings of alterations shall be approved before work is started unless deemed unnecessary by the Officer in Charge, Marine Inspection. Electrical panel P202 had circuits installed that are not on the approved electrical drawings. Circuit shall be tagged out and not used until plan review has been completed/approved. 46 CFR 91.45-1(a) (b)
Action required: 705 - Other - as specified
Resolved 5 November 2025
Resolution: Vessel submitted electrical plans to MSC and have been verified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2025 Resolved
Liquefied or non-liquefied gas is prohibited for cooking, heating, and lighting on ferry vessels, but may be used on other inspected vessels if the system in which it is used meets the applicable requirements of subpart 58.16 or subpart B of part 184 of this chapter, as appropriate, or is approved by the Commandant (CG-ENG). Multiple propane tanks had been found on board. All must be removed. 46 CFR 147.50(d)
Action required: 10 - Deficiency Rectified
Due 15 August 2025
Resolved 15 August 2025
Resolution: Vessel rep was made aware of and given the CG835 which was signed and agreed upon to remove all the propane on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2025 Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space An aggregate of more than 7.6 liters (two gallons) of flammable or combustible liquids stowed outside of an accommodation, control, or service, space (other than a paint locker) or outside of a machinery space must be stowed in a paint locker that is marked with a warning sign indicating flammable or combustible liquid storage. 46 CFR 147.45(b)(e)
Action required: 10 - Deficiency Rectified
Due 15 August 2025
Resolved 15 August 2025
Resolution: Vessel rep acnkowledged the deficiency and started to imeddietly make changes to all items stored incorrectly.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 August 2025 Resolved
Electric installations and electric equipment must be inspected at the inspection for certification and periodic inspection to determine mechanical and electrical condition and performance. Generators over-speed, and low lube oil pressure alarm was not able to be tested. The engineer currently on board could not facilitate the testing for the generator tests/shutdowns. Provide tech report for these test. 46 CFR 110.30-5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 August 2025
Resolution: vessel provided tech report for generator testing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2024 Resolved
Oxygen and acetylene cylinders located on main deck port side not stowed in a stowage rack as required by 46 CFR 147.1(b) & 147.60. 46 CFR 60(b) cylinders stowage and care of compressed gas cylinders must always be secured and, when not in use, must be stowed in a rack in an upright position, with the valve protection cap in place. Procure or fabricate a rack complying to the applicable CFR. To clear, statement with digital photo(s) to be emailed to the attending CG Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2024
Resolved 12 September 2024
Resolution: Master provided e-mail with statement and photo requirement resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 September 2024 Resolved
Observed forward generator removed. Informed and records reflected the generators main stator windings were burnt, with generator shipped out for repairs. As required by 46 CFR 91.45-1 no repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. To clear, 3rd party generator repair shop report, statement from the chief engineer stating generator was reinstalled, tested, and operating as designed shall be provided to the attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 12 September 2024
Resolution: Master provided e-mail with statement and photo requirement resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2022 Resolved
The plans required by paragraph (d)(1) of this section must be certified by a registered professional engineer to meet the design requirements in paragraph (d) of this section and in section VIII, division 1, of the ASME Boiler and Pressure Vessel Code. The pressure vessel on board the barge has a valid U1A with the ASME "U" symbol however it does not meet the additional requirements found in 46 CFR 54.01-5(c)(3) for pressure vessel use on board inspected vessels. After verification from a P.E. or the Marine Safety Center, a Coast Guard Symbol shall be applied as required by 46 CFR 54.10-3(c).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 29 June 2022
Resolution: Recieved Plan Review Letter from MSC stating pressure vessel meets requirements in Subchapter F.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.