FINN
Passenger (Inspected) · Passenger Ship class · Built 2020s · USCG Northeast District (CGD-NE) · Other hulls named FINN
FINN is a 2021 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2021, most recently in April 2026, along with 9 deficiencies.
Records from 2021 to 2026. Most recent: inspection, 2 April 2026.
- Built
- 2021
- Last inspected
- 2 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1323189
1712835
Flag
UNITED STATES
—
Maury page id
psix-1712835
Inspections, by type
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)26.9 ft × 10.0 ft × 4.9 ft
Registered tonnagegross 8 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFORTIER BOATS INC · SOMERSET, MA, UNITED STATES · built 2021
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMARBLEHEAD, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Net Ton
8 - Simplified, Gross Ton
8 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
2 April 2026
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8325058
29 April 2025
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8102831
7 May 2024
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7889266
2 April 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7886446
28 March 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7886389
5 October 2022
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7566571
25 April 2022
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7427160
11 February 2021
Initial Certification · Plan Review "T" Boat · Simplified Stability Test · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7391667
Deficiency record · 9
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 May 2024
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Proof of servicing the fireboy system was not available during inspection. Have system serviced and provide evidence to attending marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 7 May 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. No record of drills available during inspection. Maintain required log entry of all drills conducted onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 May 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date chartlet of the area of operation and the capability to determine local tide cycles. No chartlet for operating area was available onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2024
Resolved
Table 181.500(b) of this section indicates the minimum required classification for each space listed. Extinguishers with larger numerical ratings or multiple letter designations may be used if the extinguishers meet the requirements of the table. Vessel only has one 40-B:C portable fire extinguisher onboard and is required to have one additional 10-B:C.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 March 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel missed its annual inspection. Vessel must undergo an inspection for certification prior to operations.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2022
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 to 6 feet securing the waterlight around the body of the ring life buoy, attached with a corrosion resistant clip. Lifebuoy was missing a clip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2022
Resolved
Each ring life buoy must be marked with Type II retro-reflective material. The arrangement of the retro-reflective material must be as specified by IMO Resolution A.658(16). Lifebuoy was missing tape.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2021
Resolved
CONDUCT NEW TO ZONE COI INSPECTION AND DRILLS WITH USCG PRIOR TO CARRIAGE OF PASSENGERS TO INCLUDE;
ANNUAL FOCUS AREA
MERCHANT MARINER CREDENTIAL (MMC)
DRUG AND ALCOHOL PROGRAM
MAN OVERBOARD DRILL
FIRE DRILL
VESSELS LOG
NAV PUBS, CHARTS
SAFETY ORIENTATION / PASSENGER COUNT