MAURY USCG vessel records
← All vessels

ECO EXPEDITION

ECO EXPEDITION is a 2002 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 2022, most recently in May 2025, along with 3 deficiencies.

Records from 2022 to 2025. Most recent: inspection, 6 May 2025.

Built
2002
Last inspected
6 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 May 2025
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2022–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM7819
1712989
Flag
UNITED STATES
Maury page id
psix-1712989

Documentation record

Tonnage as PSIX records it3 - Simplified, Net Ton
3 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

6 May 2025 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8088107
31 October 2024 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8087933
24 May 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7916622
28 February 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7865548
11 August 2023 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7765606
22 June 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7721002
21 January 2022 Deficiency Check · DAPI Audit · Administrative Inspection · Simplified Stability Test · COI Inspection · Hull Examination · Plan Review "T" Boat
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7388345

Deficiency record · 3

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 June 2023 Resolved
Vessel must undergo an annual inspection as specified in paragraph (b)(1) of this section. Vessel must undergo an annual inspection within 3 months before or after the each anniversary date. Vessels anniversary date was 14MAR2023, and vessel is past 3 months from said date. 46 CFR 176.500(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2023
Resolved 29 June 2023
Resolution: Attending MI completed a satisfactory Annual Inspection and endorsed COI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 March 2022 Resolved
The owner of a vessel requesting initial inspection for certification shall submit for approval to the cognizant OCMI plans of... electrical installation including but not limited to... elementary one-line diagram of the power system. Approved plans do not match installation. Electrical system missing terminal block for bilge pump and 4 gauge wire from battery switch to common busbar. 46 CFR 177.202(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 28 March 2022
Resolution: Vsl rep added terminal block and replaced 8 gauge wire with 4 gauge wire from battery switch to common busbar.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 March 2022 Resolved
Shutoff valves must be metallic. Shutoff valve for bilge pump was made of PVC. 46 CFR 182.720(d)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 15 March 2022
Resolution: Owner installed a metal shutoff valve for the bilge pump.

Ownership record