Records from 2023 to 2025. Most recent: inspection, 2 May 2025.
Documentation record
Registered dimensions (L × B × D)34.8 ft × 10.0 ft × 4.0 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBARRETT MARINE COMPANY · AUBURN, WA, UNITED STATES · built 2023
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portKIKIAOLA, HI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 18 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 4
2 May 2025
Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8127066
17 April 2024
Deficiency Check · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7897304
28 June 2023
DAPI Audit · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7725358
17 May 2023
Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7690490
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2024
Resolved
Vessel has undersize life ring in service. Provide 24" serviceable life ring.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 1 May 2024
Resolution: Vessel installed satisfactory 24" serviceable life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 April 2024
Resolved
Vessel missing life jacket placard. Provide Type 1 placard and prove its visible to passengers and crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 1 May 2024
Resolution: Vessel installed life jacket placard in visible location for its passengers and crew.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 17 April 2024
Resolved
Vessel's fuel cut off valves and stowage areas for it's life jackets are missing labels. Provide visible labels and prove posting locations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 1 May 2024
Resolution: Life jacket compartments and fuel cut off valves are satisfactory labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 April 2024
Resolved
Vessel's EPIRB is not marked with vessel's name. Provide name of vessel on EPIRB.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 1 May 2024
Resolution: Vessel's EPIRB is satisfactory marked with name of vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 April 2024
Resolved
Vessel is missing 02 alcholo swabs. Provide sericeable swabs.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 April 2024
Resolved 17 April 2024
Resolution: Test strips were provided and place onboard before the end of inspection.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 28 June 2023
Resolved
A vessel must be provided with a stability letter. The letter must be posted under glass at the operating station.
MI found the vessel's stability approved by MSC for Exposed routes but a letter has not been provided. Vessel route is reduced to limited coastwise no further than 20NM from harbor of safe refuge until stability letter provided and posted.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 26 July 2023
Resolution: MSC provided approved stability letter, MI issued letter to the vessel and placed at operations station with COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 June 2023
Resolved
The number and identification of items stowed inside and their sizes must be marked in at least 2" high clear legible letters and numbers on each container. Provide satisfactory markings for life jacket stowage compartments.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 26 July 2023
Resolution: MI found satisfactory markings for each stowage compartments for all life jackets onboard.