BLUEFIN

BLUEFIN is a 2011 tank ship. The Coast Guard has recorded 7 inspections since 2022, most recently in April 2024, along with 7 deficiencies and 1 operational control.

Records from 2022 to 2024. Most recent: inspection, 9 April 2024.

Built
2011
Last inspected
9 April 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 April 2024
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2022–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9551868
1713501
Flag
LIBERIA
Maury page id
psix-1713501

Documentation record

Tonnage as PSIX records it17121 - Dead Weight, Ton
5180 - Convention (Subpart B), Net Ton
11931 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

9 April 2024 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7892626
31 March 2024 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7887662
26 February 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7868413
23 February 2023 PSC B · COC-CHEM & TVE Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7640141
11 April 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7428813
19 February 2022 PSC A · COC-CHEM & TVE Renew · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7398767
16 February 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7397508

Deficiency record · 7

08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 31 March 2024 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ON BOARD. VESSEL SELF-REPORTED MALFUNCITONING FIRE ALARM REPEATERS IN WAY OF THE ECR AND FIRE CONTROL STATION. 74 SOLAS(20) I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2024
Resolved 9 April 2024
Resolution: Recieved class report and dispensation attesting to fire detection and alarm system operational.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 February 2024 Resolved
Doors fitted in boundary bulkheads of machinery spaces at category "A" shall be reasonably gastight and self-closing. PSCO observed a self-closing door in the engine room unable to close.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 February 2024
Resolved 26 February 2024
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 21 February 2022 Resolved
Controlled tank venting systems fitted to tanks to be used for cargoes having a flash point not exceeding 60 deg Celsius shall be provided with devices to prevent the passage of flame into cargo tanks. PSCO discovered vessels secondary means of allowing full flow relief of vapor by way of P/V Breaker is not fitted with a device to prevent the passage of flame. 74SOLAS(20)vii/10.1/IBC CODE 8.3.6 CODE 50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2022
Resolved 26 February 2022
Resolution: Received Class report stating new flame screen was installed on PV breaker valve, PSCO attended the vessel and confirmed installation was all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 February 2022 Resolved
Each tankship with a vapor collection system must be fitted with a pressure-sensing device...PSCO discovered vessels installed VCS system unable to give audible and visual warning for HI or LOW pressure. 46CFR39.2013(b) Code 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2022
Resolved 26 February 2022
Resolution: Received class report stating: Per manufactures, the alarms have set test points, and the audible/visual alarm settings are not changeable for testing by the crew.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 21 February 2022 Resolved
All cargo tanks shall be provided with a venting system appropriate to the cargo being carried...Tank venting systems shall be designed so as to minimize...In the case of flammable vapors, entering or collecting in spaces or areas containing sources of ignition. PSCO discovered vessels installed secondary means of allowing relief of vapor by way of P/V Breaker to be leaking from drain fitting, allowing water/glycol mixture to escape. 74SOLAS(20)VII/10.1/IBC CODE 8.2.1 CODE 50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2022
Resolved 26 February 2022
Resolution: Received class report stating the PV breaker drain line was resealed and no apparent leaks were found, PSCO attended vessel and confirmed repair is all sat.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 21 February 2022 Resolved
The showers and eyewash shall be operable in all ambient conditions. PSCO discovered vessels STBD manifold eyewash station not to be insulated against all ambient conditions. 74SOLAS(20)VII/10.1/IBC CODE 14.3.4 CODE 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 February 2022
Resolution: Received class report stating eyewash lines were reinsulated, PSCO attended vessel and found lines were insulated properly and are all sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 21 February 2022 Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirement which may be established by the Company. No SMS procedures were provided to check self contained air support system on stern launch lifeboat or to check the foam level in the tank for deck foam, both of which were below the required level as noted in flag state inspection. An internal audit is required within 90 days. COC not issued due to the above deficiencies, re-examination for COC to be completed after deficiencies 1-3 have been corrected. 74SOLAS(20)IX/3.1/ISM CODE10.1 CODE 705ABC
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2022
Resolved 26 April 2022
Resolution: Vessel submitted documentation addressing checks in SMS for foam and air support in the lifeboat.