Records from 2022 to 2026. Most recent: inspection, 18 February 2026.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 8.0 ft
Registered tonnagegross 39 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS LLC · SLIDELL, LA, UNITED STATES · built 2022
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Simplified, Net Ton
39 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 10
18 February 2026
Examination of Repairs · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8312010
23 January 2026
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8300470
28 October 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8259760
28 October 2024
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8025580
11 October 2024
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8017756
10 April 2024
COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7892998
11 March 2024
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7876892
31 January 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7859773
3 November 2022
In-Service Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7585299
13 May 2022
Plan Review "T" Boat · Initial Certification · Construction Oversight · Simplified Stability Test · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7569543
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 October 2025
Resolved
A hatch exposed to the weather must be watertight. The gasket material for the forward and aft hatches did not provide a watertight seal. Renew the hatches to prevent the ingress of water.
46 CFR 179.360
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2025
Resolution: 10C - Corrected on the spot. Hatches were adjusted to stop water intrusion.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 October 2025
No resolution recorded
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. The vessel was constructed with general purpose resin. The under deck of the engine room compartment did not have noncombustible panels or materials. Install fire retardant insulation or similar material. Prior to the installation, provide the specs of the materials to be used to the USCG for approval.
46 CFR 177.410
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Fuel was leaking from the starboard and port side fuel shut off valve hoses. Repair the leaks.
46 CFR 182.455
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2025
Resolved 6 November 2025
Resolution: Leaked were repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 October 2025
Resolved
Electrical equipment must be installed to protect from electrical hazards. Several dead end wires were found underneath the operating station. Properly remove or cover the wires with a junction box.
46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2025
Resolved 10 November 2025
Resolution: Cables were reconnected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 October 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel, such as electrical wiring and propulsion and power supply systems, must not be made without the approval of the OCMI, except during an emergency. Proposed alterations must be approved by the OCMI before work is started. MI observed that in the engine room, the generator had been replaced by an inverter, prior to receiving approval by [name withheld] approval in this project is necessary and 110v outlets for inflatable slide shall not be used until proper approval. Also provide information and work conducted by contractor in writing to the CG.
46 CFR 176.700(a) and (b)
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2024
Resolved 26 November 2024
Resolution: Received approval from MSC. Approval uploaded into MISLE.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2024
Resolved
Code 08199: On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:
(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;
(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and
(3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck.
The high bilge water aduo alarm (ring bell) underneath the operating station was found inoperable.
46 CFR 182.530 Code 17C.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2024
Resolution: A new audio and visual alarms have been installed and tested properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 April 2024
Resolved
Code 07110: A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. All three fire buckets are 5 gallon, instead of the required 2.5 gallons. 46CFR181.610 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 22 April 2024
Resolution: New 2.5 gallon buckets were placed in service.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 31 January 2024
Resolved
Provide an audible alarm at the operating station to indicate a high water level in the engine compartment (visual alarm is operable).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 January 2024
Resolved
Install batteries in each life float's floating waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 February 2024
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 November 2022
Resolved
Provide a valid Certificate of Documentation prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 November 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 November 2022
Resolved
Provide proof of Employee Assistance Program training for all crewmembers and supervisory personnel working in a safety sensitive position. Supervisory personnel must receive at least 60 minutes of training.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 May 2022
Resolved
During an initial inspection for certification the owner or managing operator shall conduct all tests and make the vessel available for all applicable inspections discussed in this paragraph, and in Subpart H of this part, to the satisfaction of the cognizant [name withheld] cognizant OCMI to conduct new to zone inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2022
Resolution: Completed COI Inspection.