MAURY USCG vessel records
← All vessels

ECO EDISON

ECO EDISON is a 2024 offshore supply vessel. The Coast Guard has recorded 13 inspections since 2021, most recently in July 2026, along with 5 deficiencies — 1 with no resolution recorded — and 2 casualty investigations in 2024.

Records from 2021 to 2026. Most recent: inspection, 8 July 2026.

Built
2024
Last inspected
8 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 July 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2021–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1035894
WDP5024
1713732
Flag
UNITED STATES
Maury page id
psix-1713732

Documentation record

Registered dimensions (L × B × D)247.0 ft × 64.0 ft × 36.8 ft
Registered tonnagegross 6,042 / net 5,625
ITC dimensions (L × B × D)247.0 ft × 64.0 ft × 36.8 ft
ITC tonnagegross 6,359 / net 1,907
BuilderLASHIP LLC · HOUMA, LA, UNITED STATES · built 2024
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 April 2026 · expires 31 May 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6359 - Convention (Subpart B), Gross Ton
6042 - Regulatory (Subpart C or D), Gross Ton
1907 - Convention (Subpart B), Net Ton
5625 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TEE ED Offshore Supply Vessel · MISLE 1801509 · 23 July 2024 · activity 8027499

Inspection history · 13

8 July 2026 ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8437379
26 May 2026 Vessel Attendance · Damage Survey · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8383598
20 May 2025 In-Service Inspection · Annual Inspection · ACP Annual Oversight · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8141071
19 March 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8096405
7 March 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090240
4 October 2024 ACP Additional Oversight – Risk Assessment
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8014628
7 August 2024 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8088745
6 August 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7976002
23 July 2024 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8027499
12 June 2024 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7935011
22 May 2024 Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 7924118
13 May 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7911353
2 November 2021 Initial Certification · ACP Handover Survey · MTSA/ISPS Verification · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7656417

Deficiency record · 5

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 May 2026 Resolved
Winch drums should be wound to the maximum number of turns permitted and a static load test of 1.5 times the maximum working load should be applied and held by the brake. This load should then be lowered for at least one complete revolution of the barrel shaft. A test load of 1.1 times the maximum working load should then be lowered at maximum lowering speed through a distance of at least 3 m and stopped by applying the hand brake sharply. Repairs to vest davit winch and brake to meet LSA launching and embarkation appliance rules.
Action required: 705 - Other - as specified
Resolved 11 June 2026
Resolution: Repairs completed and tested to the satisfaction of the attending ACP-RO surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 May 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall satisfy the following requirements: the doors shall be self-closing and capable of closing with an angle of inclination up to 3.5 deg. Fire doors in vessel were closing improperly and inop automatic release mechanisms and unauthorized hold-backs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2025
Resolved 12 June 2025
Resolution: RECEIVED RO'S "SURVEY AFTER CONSTRUCTION VESSEL REPORT"
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 May 2025 No resolution recorded
Each survival craft shall be stowed in a state of continuous readiness: securing strap on hydrostatic release missing.
Action required: 10 - Deficiency Rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2024 Resolved
Conditions after survey. The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel reported a loss of propulsion. The stbd voith drive went off line. Determine cause and affect repairs to the satisfaction of Coast Guard and the American Bureau of Shipping (ABS). 74 SOLAS 2020 (CONS) CH-1, Reg. 11 (a).
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2024
Resolution: See Activity Number 7976002
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 June 2024 Resolved
MISLE DROP DOWN SOLAS CITES IS OUT OF DATE, PROPER CITE: SOLAS CONS 2020, Ch II-2, Regulation 9.4.1.3.6 (passenger vessel requirement applicable to the subject vessel by reference from Subchapter L)The subject regulation requires windows facing survival craft to be A-0. 835; WINDOWS FACING SURVIVAL CRAFT SHALL HAVE FIRE INTEGRITY AT LEAST EQUAL TO "A-0" CLASS. WINDOWS INSTALLED ARE NOT A-0 OR EQUIVALENT. AFT LIFERAFT STATION; ACCEPTED TEMP REPAIR OF STEEL PLATE COVERS, W/STICH WELDS & FIRE STOP FOR 30 DAYS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2024
Resolved 7 March 2025
Resolution: SEE ABS CLASS REPORT, STEEL 4MM WELDED OVER OPENING TO ACHIEVE A0

Casualty record · 2

23 July 2024Routine · role: Involved in a Marine Casualty · activity 8027499
7 August 2024Routine · role: Involved in a Marine Casualty · activity 8088745
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record