Records from 1994 to 2025. Most recent: inspection, 11 July 2025.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 20.5 ft × 7.0 ft
Registered tonnagegross 69 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERODINO INC · GUILD TN, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Regulatory (Subpart C or D), Gross Ton
53 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
11 July 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8136133
13 August 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7976405
9 July 2024
In-Service Inspection · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7954227
26 July 2023
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7753533
29 June 2022
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7490972
26 July 2021
Deficiency Check · Annual Inspection · Administrative Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7271794
19 March 2021
Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7160728
24 February 2021
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7145794
18 November 2020
Administrative Inspection · Construction Oversight
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7097850
15 April 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6939454
19 December 2018
Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6600131
12 May 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4591330
5 March 2013
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4531980
3 February 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 659179
22 November 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 372712
5 November 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 171864
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 July 2025
Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. During dredge assist operations, Vessel had a bump-n-go on a dike. Initial reports are this may have caused damage to the vessel. MI discussed no sailing the vessel with operator as MIs will be in attendance in 5 days for regularly scheduled inspection. O/O concurred. Vessel to prove proper operation to the satisfaction of attending MI prior to resuming operations.
Action required: 705 - Other - as specified
Resolved 16 July 2025
Resolution: Conducted thorough testing, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 July 2021
Resolved
Identify and repair hull damage to port stern void.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2021
Resolution: Inspected weld repairs and witnessed satisfactory air testing.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 July 2021
Resolved
Prove proper operation of starboard search light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 19 August 2021
Resolution: Received pictures via email sufficient to verify operation of searchlight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2021
Resolved
Galley space heater was found to have burn marks on cord end plug and at plug receptacle. Troubleshoot and repair as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 3 August 2021
Resolution: Space heater was troubleshot and repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2021
Resolved
Large transformer located in starboard aft engine room was found to be not mounted. Securely mount transformer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 3 August 2021
Resolution: Transformer is securely mounted to deck plate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2021
Resolved
Electrical junction box located fwd engine room was found hangine loose. Mount junction box securely.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 3 August 2021
Resolution: J-box is securely mounted to overhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2021
Resolved
Port generator windings were found to be thoroughly covered in oil. Identify source of oil leak and repair / clean windings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 20 September 2021
Resolution: Received documentary evidence that windings were cleaned and oil leak repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. It was reported river debris (log) caused STBD rudder to not operate fully. Survey vessel’s steering system and make proper repairs to the satisfaction of the CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2021
Resolution: All repairs and a satisfactory test of steering and propulsion systems have been completed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 June 2019
Resolved
Vessel does not maintain records of lifesaving equipment inspections. Inspections of lifesaving equipment, required by 46 CFR 199.190 (monthly), must be recorded in the Towing Vessel Record with number or identification of items, results of inspection, date and who performed inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 26 June 2019
Resolution: Received email containing necessary documentation.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 June 2019
Resolved
Provide records for inspection of all tow gear. Results must be recorded in Towing Vessel Record to include dates of inspection, identification of each towing gear inspected, and name of person conducting inspections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 26 June 2019
Resolution: Received email containing necessary documentation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 June 2019
Resolved
Label the zone on the fire detection panel to indicate location of alarm (i.e. Engine Room).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 26 June 2019
Resolution: Received photographic evidence via email that panel is labelled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2019
Resolved
Identify generator circuit breakers by labeling.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 26 June 2019
Resolution: Received photographic evidence via email that panel is labelled.