Records from 2022 to 2026. Most recent: inspection, 4 March 2026.
Inspection history · 8
4 March 2026
Annual Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8312368
24 February 2025
Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8081950
19 February 2025
Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8081893
7 February 2024
Annual Inspection · Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7865330
3 May 2023
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7680440
10 April 2023
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7666448
7 March 2022
COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7407453
9 February 2022
Simplified Stability Test
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7398445
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 February 2024
Resolved
A vessel on a lakes, bays, and sounds route must carry three hand red flare distress signals and
three hand orange smoke distress signals. Vessel needs two more flares to be compliant.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2024
Resolved 1 March 2024
Resolution: New flares purchased. See documents for photograph.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 February 2024
Resolved
Each life jacket and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Each life jacket and ring life buoy must be marked with "WANDONDO."
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2024
Resolved 1 March 2024
Resolution: Correct amount of properly marked life jackets. See documents for photograph.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 February 2024
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q. Grab lines were wasted and did not have a minimum breaking strength of 1,350 pounds. Retro-reflective tape was missing/wasted. Ring life buoy is no longer serviceable and must be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2024
Resolved 1 March 2024
Resolution: Ring life buoy replaced. See documents for photograph.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 February 2024
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 1 March 2024
Resolution: Container marked. See documents for photograph.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 February 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2024
Resolved 1 March 2024
Resolution: Correct amount of properly marked fire buckets. See documents for photograph.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2024
Resolved
A vessel must be fitted with ground tackle necessary for the vessel to be safely anchored. The vessel's anchor pulpit is cracked and must be repaired or replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 1 March 2024
Resolution: Pulpit replaced. See documents for photograph.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2023
Resolved
Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Fuel filters are constructed of materials other than steel and do not have heat deflector installed.
46CFR182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 3 May 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 April 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit was expired.
46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 3 May 2023