CLEAN EVERGLADES is a 2023 tank barge. The Coast Guard has recorded 8 inspections since 2021, most recently in March 2026, along with 10 deficiencies — 1 with no resolution recorded —.
Records from 2021 to 2026. Most recent: inspection, 10 March 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 4 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5696 - Convention (Subpart B), Gross Ton 5541 - Regulatory (Subpart C or D), Gross Ton 4034 - Displacement, Ton 1708 - Convention (Subpart B), Net Ton 5541 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
10 March 2026Deficiency Check · Annual Inspection · Vessel Attendance
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2026Resolved
#1 Port cargo dome water spray nozzle found clogged, demonstrate proper operation.
#1 STBD cargo dome water spray nozzle found clogged, demonstrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2026
Resolved 11 March 2026
Resolution: Removed and cleaned
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 March 2026Resolved
Appropriate segregation shall be maintained between control, monitoring alarm, and safety functions. There was no audio alarm in barge control room when testing the gen set PSTP. Also the wrong audio alarms where going off when the gas detectors was tested. Make proper repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2026
Resolved 11 March 2026
Resolution: Replaced a relay tested sat
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 10 March 2026Resolved
Communication between the Remote-Control Monitoring Station (RCMS - Tug) and the essential systems on the barge will be provided by one (1) hard wired and one (1) wireless connection. The CAMS RCMS (wired) between the tug and barge are in faulty condition. Vessel is currently operating on the wireless system. Make repairs to the wired system and demonstrate satisfactory operation of the system as per design and/or provide updated status of parts to make repair. Additionally, operational procedures/instruction must be posted for crew. 46 CFR 30.15-1 and DBA Rev. 8, 3.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2026
Resolved 11 May 2026
Resolution: Tested RCMS cable found Sat
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 March 2026Resolved
All electrical installations in hazardous locations must comply with the general requirement of the recognized standard. [name withheld] numerous electrical items that were not being maintained thru the cargo area per the standard, i.e. loose bonding cable and connectors, etc. Hazardous maintenance needs to be conducted, and the results provided to USCG for review and approval. 46 CFR 111.105.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026
Resolved 11 May 2026
Resolution: All electrical installation replaced/repaired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2026No resolution recorded
PSTP test procedure documents must be in step by step or checklist necessary to perform the test. [name withheld] that several of the PSTP task and steps (i.e. Gas Detector, PERC., Hi and Overfill, Etc) need to be amended to reflect the actual results as written or make changes necessary. Once correction are made, demonstrate to the attending MI. 46 CFR 62.01-5
Action required: 705 - Other - as specified
Due 10 April 2026 — due date passed with no resolution recorded
A cargo emergency shutdown system (ESD) shall be fitted to stop cargo flow. The vessel's ESD2 system is in a fault condition and cannot be reset. Make repairs and
demo satisfactory operations. IAW 46 CFR 30.15-1, DBA 3.3, and IGC 18.10.1.1
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 27 March 2025
Resolved 31 March 2025
Resolution: Repairs made
A continuous-reading oxygen content meter shall be fitted. 03 O2 sensors (Subcooler room, etc) are in fault condition and needs to be repaired. Make repairs and demo satisfactory operations. IAW 46 CFR 30.15-1, DBA 3.3,and IGF 9.5
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 27 March 2025
Resolved 31 March 2025
Resolution: )2 sensors calibrated
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 March 2025Resolved
Gas detection equipment shall be so designed that it may readily be tested. Testing and calibration shall be carried out at regular intervals. Several fixed Gas Detectors needs to be calibrated and no documentary proof is readily available. Additionally, a maintenance records shall be established for all fixed and portable Gas detectors per the recognized standard. IAW 46 CFR 30.15-1, DBA 3.3,and IGF 13.6.18
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2025
Resolved 31 March 2025
Resolution: Calibration complete
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 27 March 2025Resolved
Automation systems shall be designed, installed and tested in accordance with recognized standards. No documentary proof that the required PSTP is being conducted/performed. PSTP must be performed and documented. IAW 46 CFR 30.15-1 and IGC 13.8.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2025
Resolved 2 June 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 May 2024Resolved
Instruments shall be tested to ensure reliability under the working conditions. O/O reported that the USL link was inoper Vsl has both pneumatic and elect links.
Action required: 705 - Other - as specified
Resolved 30 September 2024
Resolution: repaired
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.