MAURY USCG vessel records
← All vessels

MARIE

MARIE is a 2021 tank ship. The Coast Guard has recorded 7 inspections since 2022, most recently in February 2026, along with 2 deficiencies.

Records from 2022 to 2026. Most recent: inspection, 17 February 2026.

Built
2021
Last inspected
17 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 February 2026
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2022–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9912880
9V7285
1717155
Flag
SINGAPORE
Maury page id
psix-1717155

Documentation record

Tonnage as PSIX records it8040 - Convention (Subpart B), Gross Ton
7483 - Dead Weight, Metric Ton
12217 - Displacement, Metric Ton
2412 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

17 February 2026 PSC B · COC-GAS Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8308087
18 March 2025 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8095485
13 February 2025 COC-GAS Renew · PSC B · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8075510
8 June 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7709841
23 May 2023 COC-GAS Annual · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7692314
18 April 2022 COC-GAS Renew · PSC A
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7428628
18 April 2022 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7434021

Deficiency record · 2

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 13 February 2025 Resolved
The company should establish procedures plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, shipboard operation of the environment. Vessel's SMS does not address testing procedures prior entry in the compressor and motor room when carrying anhydrous ammonia. Measures should include the ship's specific design and the use of portable gas testing equipment. 74 SOLAS (20) IX/ 3.1 ISM-PART A 7
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2025
Resolved 18 March 2025
Resolution: Received, reviewed and accepted class report from BV stating the deficiency was rectified. Class report and original Form B have been uploaded to documents.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 23 May 2023 Resolved
74Solas20 VII/13.1. A gas carrier shall comply with the reqs of the IGC and shall in addition to the reqs of the reg. I/8, I/9, and I/10, as applicable, be surveyed and certified as provided for in that code. The fixed gas detection equipment is not installed in a manner to detect Anhydrous ammonia.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 June 2023
Resolved 8 June 2023
Resolution: Changed COF

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.