MAURY USCG vessel records Sign in
← All vessels

M S WESTCOTT

M S WESTCOTT is a 1977 industrial vessel. The Coast Guard has recorded 8 inspections since 2002, most recently in December 2011, along with 19 deficiencies — 1 with no resolution recorded —.

Records from 2002 to 2011. Most recent: inspection, 13 December 2011.

Built
1977
Last inspected
13 December 2011
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

171787
Flag
UNITED STATES
367512410 (licence lapsed)
Maury page id
psix-171787

Inspections, by type

…past their stated due date1
Years with a record 6 calendar years (2002–2011)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)42.9 ft × 12.5 ft × 3.5 ft
Registered tonnagegross 26 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHANS HANSEN WELDING CO · TOLEDO, OH, UNITED STATES · built 1977
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDETROIT, MI
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Net Ton
26 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG2127MMSI 367512410 · expired · voluntarily equipped · granted 15 December 2011, cancelled 19 February 2022 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

13 December 2011 DAPI Audit
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4217374
1 December 2011 Uninspected Passenger Vessel
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4200144
17 June 2008 In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3239604
21 August 2006 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2754794
27 March 2006 Uninspected Passenger Vessel · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2621031
3 August 2005 Uninspected Passenger Vessel
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2450175
5 April 2004 Uninspected Passenger Vessel
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2055323
2 May 2002 Uninspected Other
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1611764

Deficiency record · 19

Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 13 December 2011 Resolved
Random testing not done on a statistically based method.
Due 31 January 2012
Resolved 6 August 2013
Resolution: Cleared requirments during DAPI audit for Lakes Pilots.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 13 December 2011 Resolved
EAP Policy Statement
Due 31 January 2012
Resolved 18 January 2012
Resolution: Marine Employer got a policy in place for the employees.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 13 December 2011 No resolution recorded
Supervisor 1 hour training not recived
Due 31 January 2012 — due date passed with no resolution recorded
Resolution: Marine Employer is getting training required for the Supervisor training on Feb 15th.
Lifesaving › Hand Flares › Expired
Issued 1 December 2011 Resolved
hand flares on board expired, vessel rep replaced on spot.
Action required: 705 - Other - as specified
Due 9 December 2011
Resolved 1 December 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 1 December 2011 Resolved
Company not in compliance with CG Drug and Alchol program
Action required: 705 - Other - as specified
Due 16 December 2011
Resolved 6 August 2013
Resolution: Cleared requirments during DAPI audit for Lakes Pilots.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 March 2006 Resolved
Make permanent repairs to fractured longitudinal outboard of the keel on the port side
Action required: 705 - Other - as specified
Resolved 20 July 2006
Resolution: Perminent repairs have been made.
Stability › Watertight Integrity › General
Issued 27 March 2006 Resolved
Replace existing through hull fittings with metal fittings and arrange discharge hose in a loop to rise above the waterline
Action required: 705 - Other - as specified
Resolved 20 July 2006
Resolution: New hull fittings installed.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 27 March 2006 Resolved
Provide all required publications.
Action required: 705 - Other - as specified
Resolved 20 July 2006
Resolution: New publications have been provided.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 27 March 2006 Resolved
Swing and generate a valid deviation table
Action required: 705 - Other - as specified
Resolved 20 July 2006
Resolution: New deviation table provided.
Lifesaving › Hand Flares › Quantity
Issued 27 March 2006 Resolved
Provide 3 red hand flares and 3 day smokes
Action required: 705 - Other - as specified
Resolved 20 July 2006
Resolution: Hand flares and day smokes on board.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 March 2006 Resolved
Make permanent repairs to fuel line fittings in lower lazeret aft of fuel tank
Action required: 705 - Other - as specified
Resolved 20 July 2006
Resolution: Fuel line has been repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 July 2005 Resolved
Stern light needs to be replaced.
Action required: 705 - Other - as specified
Resolved 27 March 2006
Engineering › Steering Gear System › Rudder Bearing
Issued 20 July 2005 Resolved
Rudder shaft leaks
Action required: 705 - Other - as specified
Resolved 20 July 2006
Resolution: Rudder no longer leaks.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 20 July 2005 Resolved
Hydrostatic release unit is not dated for expiration.
Action required: 705 - Other - as specified
Resolved 27 March 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 20 July 2005 Resolved
Radio liscence expired.
Action required: 705 - Other - as specified
Resolved 20 July 2006
Resolution: Radio liscence renewed.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 7 July 2005 Resolved
Bilge alarm does not work/ sound.
Action required: 705 - Other - as specified
Resolved 27 March 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 5 April 2004 Resolved
Mark vessel's name on all lifejackets.
Due 19 April 2004
Resolved 19 April 2004
Lifesaving › Lifejacket/PFD (General)
Issued 2 May 2002 Resolved
Lifejackets are Type II with no retroreflective tape. Advised owner that he need tape on his lifejackets and told him new Type I jackets already have the tape on them. LEGACY COMPONENT DESC: Retroreflective Material
Due 2 July 2002
Resolved 31 May 2002
Resolution: As per conversation with "Phil"
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 2 May 2002 Resolved
Need an additional BI fire extinguisher. LEGACY COMPONENT DESC: Number
Due 2 July 2002
Resolved 31 May 2002
Resolution: As per conversation with "Phil".

Ownership record