← All vessels
DORADO
Passenger (Inspected) · Passenger Ship class · Built 2020s · USCG Southwest District (CGD-SW) · Other hulls named DORADO
DORADO is a 2022 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2019, most recently in March 2026, along with 13 deficiencies, 2 operational controls and 2 casualty investigations between 2023 and 2024.
Records from 2019 to 2026. Most recent: inspection, 25 March 2026.
- Built
- 2022
- Last inspected
- 25 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2023–2024
Identity
1324772
WDM8995
1718261
Flag
UNITED STATES
368248520
Maury page id
psix-1718261
Inspections, by type
…with no type recorded2
Years with a record
6 calendar years (2019–2026)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)124.3 ft × 34.4 ft × 11.3 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)124.3 ft × 34.4 ft × 11.3 ft
ITC tonnagegross 414 / net 142
BuilderMAVRIK MARINE INC · LA CONNER, WA, UNITED STATES · built 2022
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it414 - Convention (Subpart B), Gross Ton
96 - Regulatory (Subpart C or D), Gross Ton
142 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
96 - Regulatory (Subpart C or D), Gross Ton
142 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM8995MMSI 368248520 · active · compulsorily equipped · granted 7 April 2022, expires 7 April 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 12
25 March 2026
Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8332111
15 May 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8134919
25 October 2024
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8024924
25 October 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8026106
17 October 2024
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8025676
16 May 2024
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7913184
6 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7875048
27 July 2023
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7753548
9 July 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7738845
9 July 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7743387
12 May 2022
COI Inspection · Initial Certification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7448823
19 May 2019
Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7438878
Deficiency record · 13
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 October 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to:(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel experienced a fire while underway in the port side engine room from potential damaged wiring and surrounding batteries. Submit technician's report with root cause analysis, and repair proposal to the satisfaction of the Marine Inspector.
46 CFR 120.200(b)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 October 2024
Resolved
A fixed gas fire extinguishing system aboard a vessel must be approved by the Commandant, and be custom engineered. Vessel's fire suppression system for the port side engine room had been deployed due to a fire. Repair system to the satisfaction of the attending marine inspector.
46 CFR 118.410(a)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's port side shaft was found damaged by signs of delamination. Conduct damage survey of the shaft and submit findings and repair proposal to the Marine Inspector.
46 CFR 119.200(a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 October 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. While on scene the MI was unable to properly inspect the damaged sustained by the fire due to lack of power on board and the area being covered in suet. Clean and regain power to the vessel to conduct a thorough and satisfactory inspection of the vessel by the Marine Inspector.
46 CFR 116.100(a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2024
Resolved
An internal structural examination conducted in compliance with § 115.600 of this part may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's... the hull plating. Marine inspector observed an incomplete weld 4" in length in port side void 1, approximately 17" forward of the collision watertight bulkhead. 46 CFR 115.610(b)
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 May 2024
Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural or powered supply and exhaust ventilation. During operational test of port side engine room power damper, the damper louvers failed to fully close. 46 CFR 116.610(d)
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 May 2024
Resolved
In addition, the owner shall, prior to receiving a Certificate of Inspection, submit for approval to the Marine Safety Center, three copies of the following plans..Fire protection equipment installation including, but not limited to...Portable fire extinguisher types, sizes and locations. MI observed the posted plan identifying portable extinguishers is incorrect regarding size and location of equipment onboard. 46 CFR 116.202(b)(8)(v)
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 May 2024
Resolved
A hatch cover must...Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. MI observed broken hatch cover loss prevention device for port void 3 hatch cover. 46 CFR 116(b)(2)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2024
Resolved
Damaged rub rail idenified IWO port bow of vessel. Replace damaged material in kind, no later than 30 days.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 July 2023
Resolved
THE MINIMUM NUMBER OF PORTABLE FIRE EXTINGUISHERS REQUIRED ON A VESSEL MUST BE ACCEPTABLE TO THE COGNIZANT [name withheld] NOT LESS THAN THE MINIMUM NUMBER REQUIRED BY TABLE 118.500(a). VESSEL DOES MEET THE MINIMUM FIRE EXTINGUISHERS REQUIREMENTS. ENSURE MINIMUM FIRE EXTINGUISHERS INSTALLED MEET REQUIREMENTS TO THE SATISFACTION OF THE MARINE INSPECTOR.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 July 2023
Resolved
NONCONDUCTING MATS OR GRATING MUST BE PROVIDED ON THE DECK IN FRONT OF EACH SWITCHBOARD. VESSELS MAIN SWITCHBOARD MISSING NONCONDUCTIVE MAT. ENSURE NONCONDUCTIVE MAT IS INSTALLED IN FRONT OF THE MAIN SWITCHBOARD TO THE SATISFACTION OF THE MARINE INSPECTOR.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2023
Resolved
AT LEAST ONE RING BUOY MUST BE FITTED WITH A FLOATING WATERLIGHT. VESSELS WATERLIGHT IS NOT MOUNTED AND MAY BE SUSCEPTIBLE TO DAMAGE AND INADVERTANT LIGHT ACTIVATION. VESSEL TO MOUNT FLOATING WATERLIGHT TO THE SATISFACTION OF THE MARINE INSPECTOR.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Fuel oil leak detected on starboard engine. Determine location of leak, repair engine, and clean up fuel to the satisfaction of the attending marine inspector. 46 CFR 119.200(a)
Casualty record · 2
9 July 2023Routine · role: Involved in a Marine Casualty · activity 7743387
25 October 2024Routine · role: Involved in a Marine Casualty · activity 8026106
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.