Records from 2022 to 2026. Most recent: inspection, 14 January 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
14 January 2026
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8296483
14 May 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8136123
4 September 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7996272
28 June 2024
Drydock Exam · COI Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7944495
27 September 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7776430
2 August 2022
COI Inspection · Deficiency Check · Initial Certification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7512924
5 April 2022
Administrative Inspection · Hull Examination · Plan Review "T" Boat · Deadweight Survey · Construction Oversight
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7426318
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2022
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Child life jackets were found stored in the same location as adult life jackets. Separate child life jackets and mark the stowage location of the child life jackets.
46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 16 August 2022
Resolution: 03 child life jackets are now onboard and stored in their designated location.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2022
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high.
Mark the number of adult and child life jackets stored in each location and mark whether the life jacket is an adult or a child life jacket.
46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 16 August 2022
Resolution: The life jacket storage locations are marked IAW the regulations.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2022
Resolved
Supervisors for the drug and alcohol program must be provided with 1 hour of additional supervisor training.
The owner was unable to provide the supervisor training required by 46 CFR 16.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 29 August 2022
Resolution: USCG received evidence of supervisor DAPI training IAW regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 August 2022
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: be buoyant, be of at least 18.3 meters (60 feet) in length, be non-kinking, have a diameter of at least 7.9 millimeters ( 5/16 inch), have a breaking strength of at least 5 kilonewtons (1,124 pounds), and be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.
The ring life buoy was found with incorrect lifeline specs and was not 60' in length.
46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 16 August 2022
Resolution: The operator purchases and placed into service a life line that complies with regulations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2022
Resolved
Installation of seats must provide for ready escape. Seats, including fixed, temporary, or portable seats, must be arranged as follows: An aisle of not more than 4.572 meters (15 feet) in overall length must be not less than 610 millimeters (24 inches) in width. Only one means of escape is required from a space where: The space has a deck area less than 30 square meters (322 square feet).
Initial construction of the vessel provided a permanently fixed stool seat in front and behind of the permanently mounted table located centerline. The aisle space between the passenger seats and the fixed stool seat was found to be less than 24 inches in width.
One fixed stool seat shall be removed to provide the one means of escape from passenger seating. The owner elected to remove the forward stool seat.
46 CFR 177.820
Action required: 705 - Other - as specified
Due 2 August 2022
Resolved 2 August 2022
Resolution: The operator removed the forward bar stool seat which allows for emergency escape.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to: damage repair or replacement, other than replacement in kind, of electrical wiring. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant OCMI.
Marine inspector identified the installation of new unapproved 16 AWG lighting conductors and unapproved overcurrent protection (blade fuses) without plan approval.
Remove the conductors or submit new plans MSC for approval.
46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 29 August 2022
Resolution: Updated electrical drawings were submitted to MSC on this date.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 2 August 2022
Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Except on a vessel limited to daytime operations, the compass must be illuminated.
The vessel was constructed without a magnetic compass and is authorized long voyages on LBS route.
46 CFR 184.402
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 16 August 2022
Resolution: The operator installed a magnetic compass at the operating station.