YIANNIS LATSIS

YIANNIS LATSIS is a 2022 tank ship. The Coast Guard has recorded 3 inspections since 2022, most recently in December 2025, along with 4 deficiencies.

Records from 2022 to 2025. Most recent: inspection, 10 December 2025.

Built
2022
Last inspected
10 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 December 2025
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2022–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9923487
1720017
Flag
GREECE
Maury page id
psix-1720017

Documentation record

Tonnage as PSIX records it154792 - Convention (Subpart B), Gross Ton
299999 - Dead Weight, Ton
342560 - Displacement, Ton
106095 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

10 December 2025 Deficiency Check · COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8281768
20 December 2023 COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7831071
7 December 2022 COC-TVE Renew · PSC A
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7597143

Deficiency record · 4

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 December 2023 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIPS OR PERSONS ON BOARD. BALLAST PUMP NO.1 UPPER SHAFT SEAL LEAKING. VESSEL SHALL NOT USE BALLAST PUMP NO.1 UNTIL SHAFT SEAL REPLACED. 74 SOLAS (20) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 November 2025
Resolution: Vessel provided class documentation attesting to the repairs completed by the company on 23DEC25.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 20 December 2023 Resolved
THE SYSTEM SHALL BE CAPABLE OF: DELIVERING INERT GAS TO THE CARGO TANKS AT A RATE OF AT LEAST 125% OF THE MAXIMUM RATE OF DISCHARGE CAPACITY OF THE SHIP EXPRESSED AS A VOLUME. NO.1 BLOWER IS UNABLE TO MEET 125% REQUIREMENT DUE TO SOLENOID FAILURE ON IGS DISCHARGE VALVE FROM BLOWER. VESSEL SHALL USE NO.2 AND NO.3 BLOWERS ONLY UNTIL SOLENOID IS REPAIRED. 74 SOLAS (20) II-2/4.5.5.1.1 FSS CODE 15.2.2.1.2.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 December 2025
Resolution: Vessel provided class documentation attesting to the repairs completed by the company on 23DEC25.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 December 2022 Resolved
The last 1.0 meter (3.3 feet) of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be- painted in the sequence of red/yellow/red. The width of the red bands must be 0.1 meter (0.33 feet)and the width of the yellow band must be 0.8 meter(2.64 feet). PSCO observed that all four vapor connections were half painted- only the first .5 meter of the vapor connection had the required paint scheme. - 46 CFR 39.2001(h)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 December 2022
Resolved 8 December 2022
Resolution: Vessel provided pictures of the vapor manifolds painted with the appropriate markings to the satisfaction of the USCG.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 December 2022 Resolved
Tank overfill alarm must-be identified with the legend "TANK OVERFILL ALARM" in black letters at least 50.8 millimeters (2 inches) high on a white background. PSCO observed the signage was incorrect, did not use verbiage required and was on a silver background. - 46 CFR 39.2007(d)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 7 December 2022
Resolved 7 December 2022
Resolution: Ships force corrected deficiency with verbiage and background of signage to the satisfaction of the USCG.