Records from 2001 to 2018. Most recent: inspection, 25 January 2018.
Inspection history · 22
25 January 2018
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6343814
26 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6139962
4 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6117839
18 February 2016
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5817019
4 February 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5809654
3 February 2012
Annual Inspection · MTSA Verification · Commercial Dive Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4263771
21 December 2010
Internal Structural Exam · Examination of Repairs · Commercial Dive Inspection · MTSA Verification · Drydock Exam · Hull Examination · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3914283
12 January 2010
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3662868
30 December 2008
Periodic Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3386261
31 July 2008
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3285239
30 July 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3659909
22 January 2008
Commercial Dive Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3159087
8 January 2007
Re-Inspection · MTSA Verification · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2868632
26 August 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2761793
7 January 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2270577
7 January 2005
MTSA Verification · Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2270587
6 January 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2270238
14 January 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1984822
17 November 2003
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1949547
2 January 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1725067
8 February 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1485082
24 January 2001
Type not recorded
No type recorded · CGC POINT BAKER · USCG Heartland District (CGD-H) · Activity 1520998
Operations/Management › Vessel Activity › Other
Issued 4 April 2017
No resolution recorded
Dive equipment not tested as required. Can not operate dive equipment until equipment recertified. Must be remedied prior to dive operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Lifesaving › Launching Appliances › Davit
Issued 4 April 2017
No resolution recorded
Rescue boat davit needs to be of an approved type and must be fitted with a power winch motor; prior to next drydocking (14JAN2019).
Condition: Improper Installation
Action required: 705 - Other - as specified
Lifesaving › Inflatable Liferafts › Not on Board
Issued 18 February 2016
Resolved
Install liferafts (one port and one stbd) and float free devices.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2016
Resolved 22 February 2016
Resolution: Liferafts installed properly.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 18 February 2016
Resolved
Repair stbd generator fuel pressure lines and fittings.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2016
Resolved 22 February 2016
Resolution: Stbd generator fuel pressure lines and fittings repaired.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 18 February 2016
Resolved
Conduct drills (Fire, MOB, abandon ship).
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2016
Resolved 22 February 2016
Resolution: All drills conducted satisfactorily.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 February 2016
Resolved
Demonstrate E-lighting during loss of power.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2016
Resolved 22 February 2016
Resolution: Emergency lighting sat.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 February 2016
Resolved
Properly adjust watertight doors.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2016
Resolved 22 February 2016
Resolution: All watertight doors repaired.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 18 February 2016
Resolved
Provide updated navigation charts of the vessel's operating areas.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Vsl representative provided order receipt for numerious area charts.
Electrical › Electric Generation Source (service) › Generator
Issued 18 February 2016
Resolved
Repair exhaust lagging on port generator.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Lagging replaced by generator service technician with vsl crew present.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 18 February 2016
Resolved
PFD chem lights expired.
Due 18 February 2016
Resolved 18 February 2016
Resolution: Updated chem lights fitted during inspection.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 18 February 2016
Resolved
Repair stbd main engine tachometer.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Repaired during inspection.
Engineering › Fuel Oil Service System › Piping
Issued 3 February 2012
Resolved
Provide approved flexible non-metallic fuel hoses for prime movers on back deck of vessel.
Action required: 705 - Other - as specified
Resolved 3 February 2012
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 21 December 2010
Resolved
Provide a tonnage domestic tonnage cert issued by a recognized classification socitety.
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 3 February 2012
Lifesaving › Lifebuoys › Serviceable
Issued 21 December 2010
Resolved
Replace the grab lines on the port superstucture ring buoy.
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 3 February 2012
Engineering › Pressure Vessel › Relief Valve
Issued 21 December 2010
Resolved
Provide annual relief valve testing of the stbd P/V in aft Engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 3 February 2012
Lifesaving › Lifefloat › Float-free Link
Issued 12 January 2010
Resolved
Provide weak-link with service tag and correct breaking strengh.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2010
Communications › Alarms/Indicators › General Alarm
Issued 12 January 2010
Resolved
General alarm was inop while on emergency power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2010
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 January 2009
Resolved
Provide an updated approved fire and safety plan to the satisfaction of an attending Coast Guard inspector.
Due 15 February 2009
Resolved 14 January 2011
Resolution: Approved fire safety plan was located on messdeck, approved by MSU Houma inspector P. FLood on 30 Mar 2009.
Lifesaving › Lifebuoys › Not on Board
Issued 14 January 2009
Resolved
Provide 02 ring buoys to bring total to 08 prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2009
Navigation › Piloting/Steering › Marine Charts
Issued 14 January 2009
Resolved
Provide updated charts of vessel's operating area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2009
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 14 January 2009
Resolved
Provide a licenses mate prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2009
Documentation › Safety/Response Plans/Programs
Issued 17 November 2003
Resolved
Several discrepancies identifed on fire control plan. Vessel rep to make necessary corrections and provide to MSO for approval. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 December 2003
Resolved 14 January 2004
Resolution: completed all necessary corrections and delivered to MSO for approval.
Navigation › Piloting/Steering
Issued 8 February 2002
Resolved
PRIOR TO SAILING REPAIR PRIMARY SOUND PRODUCING DEVICE LEGACY COMPONENT DESC: NAV RULES
Condition: Improper/Lack of Maintenance
Due 8 February 2002
Resolved 8 February 2002
Lifesaving › Rescue Boat
Issued 8 February 2002
Resolved
PROPERLY STENCIL RESCUE BOAT IAW 46 CFR 131.855 LEGACY COMPONENT DESC: MARKINGS
Condition: Improper/Lack of Maintenance
Due 8 February 2002
Resolved 8 February 2002
Pollution Prevention/Response › Prevention Equipment
Issued 8 February 2002
Resolved
RENEW SEWAGE VENT FLAME SCREEN LEGACY COMPONENT DESC: SEWAGE VENT
Condition: Improper/Lack of Maintenance
Due 8 February 2002
Resolved 8 February 2002
Communications › Internal Communications System › Sound-powered Telephone
Issued 8 February 2002
Resolved
DEMONSTRATE PROPER OPERATION OF THE ENGINE ROOM SOUND POWERED PHONE VISUAL / AUDIBLE CALL INDICATOR UNDER FINAL EMERGENCY POWER.
Condition: Improper Installation
Due 8 March 2002
Resolved 8 February 2002
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 8 February 2002
Resolved
PROVIDE LINE THROWING APPLIANCEAND ASSOC EQUIP IAW 46 CFR 170
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 March 2002
Resolved 10 January 2005
Construction/Loadline › Structures › Door
Issued 8 February 2002
Resolved
PROPERLY STENCIL ALL WATERTIGHT DOORS
Condition: Improper/Lack of Maintenance
Due 8 February 2002
Resolved 8 February 2002