Records from 1993 to 2026. Most recent: inspection, 11 June 2026.
Inspection history · 28
11 June 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8377159
28 October 2025
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8264198
29 August 2025
Appeal
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8229590
31 July 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8186927
23 June 2025
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8161505
21 June 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7941641
7 August 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7762565
5 July 2023
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7733553
20 October 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7581101
6 June 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7470429
21 May 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7201947
1 March 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7148212
21 December 2020
DAPI Audit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7114967
30 June 2020
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7204109
31 May 2020
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6956557
12 August 2019
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6782544
27 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6549745
1 February 2013
MTSA Verification · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4529244
21 June 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4060216
9 February 2010
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3678057
2 December 2009
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3644040
10 May 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2927229
1 December 2006
MTSA Verification
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2832490
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957781
12 October 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 95178
10 February 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 199323
10 February 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 755834
22 October 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 8800
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2025
No resolution recorded
Any piping system that penetrates the hull below the waterline must be fitted with an accessible valve, located as close to the hull penetration as is practicable, for preventing the accidental admission of water into the vessel either through such pipes or in the event of a fracture of such pipe. The non-integral keel coolers do not have a stop-valve, directly plumbed to the port and starboard engines. Vessel shall install valves at each intake and discharge of installed keel coolers.
46 CFR 143.250(d)
Updated on 19May2026 through A/N: 8229590, compliance with this requirement shall be prior to completion of the vessel’s next scheduled drydock examination (due by 05Jul2028).
Action required: 705 - Other - as specified
Due 30 August 2025 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 31 July 2025
Resolved
Existing vessels must meet the pilot house alerter and towing machinery requirements no later than 5 years after issuance of the first COI for the vessel. Vessel does not have pilot house alerter installed in either pilot house. Vessel is limited to single-shift operations. Any time a shift change is required, there shall be an alternate crew and a log entry made.
46 CFR 143.200(c)
Action required: 705 - Other - as specified
Due 31 July 2025
Resolved 28 October 2025
Resolution: Attended the vessel and witnessed the operation of the installed BNWAS system (see photos).
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 31 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Outboard starboard rudder found with heavy deflection in rudder post from previous impact. In addition, rudder stiffener had a cracked weld. vessel to repair prior to credit drydock.
46 CFR 143.205(a)
Action required: 705 - Other - as specified
Due 31 July 2025
Resolved 5 August 2025
Resolution: Vessel removed rudder and replaced rudder post. Rewelded cracked stiffener. Examined bearings and found suitable for continued use.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 23 June 2025
Resolved
Each cable or wire must be supported in order to avoid chafing or other damage. Engine room bilge wire from 120v breaker on aft bulkhead inboard of watertight door found to be chafed with electrical tape.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2025
Resolved 10 July 2025
Resolution: Received photos attesting to the replacement fo the bilge electrical wire.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 23 June 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. On fly bridge, 02 electrical outlets were open, one damaged by space heater plugged in with light fire damage.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2025
Resolved 10 July 2025
Resolution: Received photos attesting to the repairs of the 02 electrical outlets on the fly bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 June 2025
Resolved
Each towing vessel operating in coastwise service must have a line throwing applicance approved under approval 160.040. Vessel does not have a line throwing applicance onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2025
Resolved 7 July 2025
Resolution: Received proof of vessel having required line throwing appliance onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2025
Resolved
The master must ensure tat all lifeaving equipment is properly maintained and ready for use at all times. Both ring life buoys had showed signs of heavy UV deterioration on grablines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2025
Resolved 7 July 2025
Resolution: O/O provided photos proving the replacement of both ring life buoys.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 23 June 2025
Resolved
Each towing vessel must be equiped with an industrial type first aid kit or cabinet, appropriate to the size of crew and operating conditions...Must have blod pressure readings, splint broken bones, and large bandages. First aid kit was expired and did not have blood pressure or splint, or heavy bandages.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 June 2025
Resolved 23 June 2025
Resolution: Vessel representative placed order for replacement first aid kit prior to inspector departure.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2025
Resolved
Decks and bulkheads designed to be watertight must be maintained in that condition. Bulkhead prenetration from engine room forward, outboard of watertight door (wire run) was open and required sealing. crew corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 June 2025
Resolved 23 June 2025
Resolution: Vessels crew corrected deficiency on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 23 June 2025
Resolved
Immersion suit carried on towing vessels must meet the requirements of subpart 199.70(c). Each immersion suit must be marked in such a way as to identify the vessel to which it belongs. Immersion suits were unmarked.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 June 2025
Resolved 23 June 2025
Resolution: Vessels crew adequately marked all imersion suits prior to inspector departure.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 23 June 2025
Resolved
A towing vessel must carry adequate and up to date charts, maps, and nautical publications. Charts, including electronic charts acceptable to the Coast Guard. Vessel was operating with recreational version of rosepoint. Operator obtained commercial charts for trial and must provide evidence of full time solution.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 June 2025
Resolved 23 June 2025
Resolution: Operator installed commercial version of rosepoint as a trial, and is seeking permenant subscription and implementation.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 June 2025
Resolved
Each towing vessel operating on and oceans , coastwise route must carry an (EPIRB), the name must be marked or painted on each EPIRB. NOAA registration sticker was not installed on EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 June 2025
Resolved 23 June 2025
Resolution: Vessels crew applied NOAA registration sticker to EPIRB prior to inspector departure.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 23 June 2025
Resolved
Existing vessels must meet the pilot house alerter and towing machinery requirements no later than 5 years after issuance of the first COI for the vessel. Vessel did not have pilot house alerter installed in either pilot house. Required installation at next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2025
Resolved 28 October 2025
Resolution: See A/N: 8264198
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 23 June 2025
Resolved
No later than July 22, 2019, the owner or managing operator must implement a health and safety plan... and include record keeping procedures. the owner, managing operator, or master must ensure that all persons onboard a towing vessel comply with health and safety plan. vessel did not have a health and safety plan onboard.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 June 2025
Resolved 23 June 2025
Resolution: Vessel crew obtained health and safety plan from office to maintian onboard prior to inspectors departure.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 7 August 2023
Resolved
Each towing vessel operating in Oceans and Coastwise service must have a line throwing appliance approved under approval series 160.040. Marine inspector observed that vessel did not have line throwing appliance. 46 CFR 141.385; 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 7 August 2023
Resolution: O/O provided a satisfactory order receipt for provision of line throwing appliance
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2021
Resolved
Lifejackets must have the following attachments and fittings:(1) Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket.(2) Each lifejacket must have a whistle firmly secured by a cord to the lifejacket. The lifejackets on board did not have a whistle nor a light. Required to provide each lifejacket with a whistle and light.
46 CFR 141.340 (g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 7 June 2021
Resolution: Recevied pictures of lifejackets with a whistle and light attached.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2021
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, and identity. The equipment may be identified in words or with the appropriate symbol from IMO Resolution A.760(18) (incorporated by reference, see § 136.112 of this subchapter). Required to label the location where the lifejackets are stowed.
46 CFR 141.340 (h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 7 June 2021
Resolution: Received pictures of marked stowage location.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 21 May 2021
Resolved
Immersion suits or anti-exposure suits must be stowed so they are readily accessible. The stowage positions must be marked with either the words “IMMERSION SUITS” or “ ANTI-EXPOSURE SUITS” as appropriate, or with the appropriate symbol from IMO Resolution A.760(18). Required to label where the immersion suits are stored.
46 CFR 141.350 (b)
46 CFR 199.70 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 7 June 2021
Resolution: Received picture of marked stowage location.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2021
Resolved
Storage of flammable or combustible products. Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet that is secured to the vessel.
46 CFR 142.225
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 24 June 2021
Resolution: Flam locker secured to vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2021
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Required to replace expired eye wash and ensure everything in kit is valid.
46 CFR 140.435
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 7 June 2021
Resolution: Received picture of new eye wash set to expire in APR 2024.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 May 2021
Resolved
Fire-detection systems on board the vessel, must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section. Required to test all smoke and fire detection systems annually.
46 CFR 142.240
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 24 June 2021
Resolution: Received fire servicing report.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 21 May 2021
Resolved
Each towing vessel must be fitted with a general alarm that is capable of notifying persons in any accommodation, work space, and the engine room;
and has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station". Required to install a general alarm in the engine room.
46 CFR 143.235
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 14 June 2021
Resolution: Received a video of the newly installed general alarm working.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 May 2021
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see § 136.112 of this subchapter). Required to install smoke detectors in the staterooms.
46 CFR 142.330 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 7 June 2021
Resolution: Received pictures of smoke detectors installed in the staterooms.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 May 2021
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least
25 millimeters (1 inch) high: ‘‘WATERTIGHT DOOR—KEEP CLOSED’’ or ‘‘WATERTIGHT HATCH—KEEP CLOSED". Required to label WT doors.
46 CFR 144.160 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 11 June 2021
Resolution: Received picture of marked WT doors
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 31 May 2020
Resolved
Adjust dogs to ensure closure of all watertight doors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 30 June 2020
Resolution: All doors adjusted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 May 2020
Resolved
Fire Detection System;The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 30 June 2020
Resolution: Verified NICET level IV certification.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2020
Resolved
Provide the appropriate number of Type I PFDs and Immersion Suits for the amount of individuals permitted on the vessel as it is listed on the vessel's COI. Currently your COI allows a total of 6 people on board.
Action required: 10 - Deficiency Rectified
Due 23 July 2020
Resolved 23 June 2020
Resolution: PFDs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2020
Resolved
If more than on lifebuoy is carried, at least one must not have a lifeline attached. (A detachable clip allowing quick release may be allowed)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 30 June 2020
Resolution: Verified.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 May 2020
Resolved
The name of the towing vessel must be marked or painted in clearly legible letters on each EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 30 June 2020
Resolution: Verified NOAA sticker.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 May 2020
Resolved
Hydrostatic release for float free EPIRB expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 30 June 2020
Resolution: Hydrostatic release valid.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2020
Resolved
A towing vessel that is certificated for rivers, lakes, bays, and sounds must be equipped with either: an approved 160-B semi-portable fire extinguishing system to protect the engine room; or a fixed-extinguishing system (as defined in 46 CFR 136.110)installed to protect the engine room. (Provide documentation that the current arrangement meets this. Unable to see data plate)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 30 June 2020
Resolution: Discussed CO2 bottles with [name withheld]2 bottles currently being used in engine room space are an equivalant to the requirment to have a 160-B extinguisher.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 September 2018
Resolved
IMO: Vsl is broadcasting no IMO #,
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 August 2019
Resolution: Vessel's AIS is properly broadcasting. Verified in VIVS.