Records from 2022 to 2026. Most recent: inspection, 24 April 2026.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 April 2026
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. The vessel has pitting on the portside forward compartment. Temporary repair using epoxy was approved.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2026
Resolved 8 June 2026
Resolution: MI witness satisfactory epoxy repair on portside pitting.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 July 2025
Resolved
An adult life jacket is required to be carried for each person onboard the vessel. The vessel was missing 5 life jackets. The passenger count is reduced to no more than 28 passengers until the 5 life jackets are onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 30 July 2025
Resolution: Operator provided video evidence showing the missing life jackets have been replaced and marked IAW regulations.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 July 2025
Resolved
Connections made to battery terminals must be permanent type connectors. Spring clips are prohibited. Trickle charge connection to battery was using spring clips.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 30 July 2025
Resolution: Operator provided photograph showing ring-style connectors from the battery charger to the battery.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2025
Resolved
A vessel must carry one floating waterlight. Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy... must be attached to the lanyard with a corrosion-resistant clip. The lanyard was spliced to the life ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 30 July 2025
Resolution: Operator provided photograph showing waterlight has been attached to ring buoy using non-corrosive clip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2025
Resolved
Each life ring buoy must be marked with type II retroreflective tape. There was no retroreflective tape on the life ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 30 July 2025
Resolution: Operator provided photograph showing retroreflective tape has been attached to ring buoy.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2025
Resolved
waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacle onboard is plastic.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 30 July 2025
Resolution: Operator provided photograph showing non-combustable trash cans have been placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 May 2024
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter.
Vessel had a 20 inch life buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 2 June 2024
Resolution: Provided evidence of correct size life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 May 2024
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
Floating waterlight lanyard was over 6 feet.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 2 June 2024
Resolution: Provided evidence of correct size lanyard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 May 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
Vessel did not possess any portable battery lights.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 20 August 2024
Resolution: Operator purchased 02 rechargable, batteray operated lights and installed on vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 May 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
First aid kit had expired contents.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 20 August 2024
Resolution: Operator replaced all expired items.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 May 2024
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high level….
Bilge high water alarms for both hulls do not have visual indicators.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 20 August 2024
Resolution: The vessel has visual indicators for all bilge alarms. At the time of COI Inspection, the operator was unaware of location of visual indicators. AFter consulting drawings he located the indicators, located at the operating station, and tested.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 August 2022
Resolved
On a vessel of 26 ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. The spaces with the high level alarms are located below passenger seating areas and not easily accessible during normal operations. The high level alarms are situated at least 2 ft above the bilge. Lower alarms closer to bottom of bilge for more immediate notification of water ingress.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2022
Resolved 22 August 2022
Resolution: High lvl alarm floats installed within 6inch of bilges. Tested sampling of alarms.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2022
Resolved
Electrical equipment on a vessel must be installed and
maintained to protect from electrical hazards and shock. Wiring for the electric submersible bilge pumps is not
secured in a way that may damage equipment and present
hazards.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2022
Resolved 22 August 2022
Resolution: Connections secured with butt-connections and electrical tape, found sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2022
Resolved
A vessel must be provided with bilge pumps to dewater spaces below deck. The electric submersible bilge pump(#6 Starboard) is inoperable. Repair or replace affected pump and prove proper operation to satisfaction of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2022
Resolved 22 August 2022
Resolution: Tested pump all sat
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 August 2022
Resolved
A penetration in a watertight bulkhead must be made watertight. The transom has 02 holes that are open and not watertight. Ensure both holes are made watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2022
Resolved 22 August 2022
Resolution: Penetrations found with screw caps installed, found watertight.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 August 2022
Resolved
The person in command of a documented vessel must produce the COD or state registration. Vessel is not required to have a COD, but could not provide evidence of State Registration. Provide evidence of State Registration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2022
Resolved 22 August 2022
Resolution: Proof of NH state registration onboard
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 August 2022
Resolved
Drill and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include date of drill and training and general description of drill scenario and training topics. Vessel is new to service and did not have any drill records. Vessel to create recordkeeping for drills and trainings and record drills conducted during COI inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2022
Resolved 22 September 2022
Resolution: O/O created training log to document any/all drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 August 2022
Resolved
Gauges to indicate engine RPMs must be provided for all propulsion engines installed on vessel. Vessel did not have engine RPM gauges installed. Install guages.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2022
Resolved 22 September 2022
Resolution: Installed new Tachometers and test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 August 2022
Resolved
Each lifejacket must be marked in accordance with retro reflective material approved IAW 46 CFR 164.018 and applied as specified by IMO Resolution A.658(16). 50% of the vessel's onboard lifejackets retro was wasted and/or ineffective. Replace retro materiel on lifejackets as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2022
Resolved 22 August 2022
Resolution: New retro tape placed on lifejackets.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 August 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights located at the operating station and the other at the access to the propulsion machinery space. Vessel did not have portable lights. Provide adequate portable lights at the locations prescribed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2022
Resolved 22 August 2022
Resolution: Two flashlights available onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 August 2022
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard. The words FIRE BUCKET must be stenciled in a contrasting color on each bucket. Vessel did not have any fire buckets. Provide 3 fire buckets that meet regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2022
Resolved 22 August 2022
Resolution: 5 gal. buckets x3 found onboard with lanyards. Buckets have the necessary holes cut out to equal 2.5 gal. per bucket.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 August 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1" high indicating purpose of the valve and direction of operation. Vessel's fuel oil shutoffs were not labeled. Label shutoffs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2022
Resolved 22 August 2022
Resolution: Shut-off hatch, labeled, all sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2022
Resolved
Electrical equipment on the vessel must be installed and maintained to protect from electrical hazards and electrical shock. The vessel has dead end wiring in the overhead of the toilet space. Remove electrical hazards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2022
Resolved 22 September 2022
Resolution: Removed dead end wiring and secured any remaining connections in a junction box.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 August 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2022
Resolved 22 September 2022
Resolution: Placed applicable charts and pubs on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2022
Resolved
A submersible electric bilge pump may be used provided
that a shutoff valve is installed at the hull penetration. The shutoff valve must be metallic. Vessel did not have any positive action valves installed for the overboard discharge lines for the electric bilge pumps. Install positive action valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2022
Resolved 22 September 2022
Resolution: O/O installed new metallic valves at hull penetration along with 90 degree fittings to prevent kinking.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2022
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Vessel was equipped with a recreational type approved <20 inch lifebuoy. Provide appropriate 24 inch, orange, lifebuoy on board. Due on 11SEP22, to coincide with due date of deficiencies issued during Initial COI Inspection.
46 CFR 180.70(a)(2) - 705c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2022
Resolved 22 September 2022
Resolution: Place onboard a new, approved life ring.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2022
Resolved
A vessel must comply with the structural design requirements of; Aluminum hull vessels: For a vessel of not more than 30.5 meters (100 feet) in length: ABS Steel Vessel Rules (<61 Meters), with the appropriate conversions from the ABS Aluminum Vessel Rules. Found approximately six pinhole penetrations surrounding the through-hull fitting for the outboard engine controls, on both port and starboard hulls on the transom. Temporarily repaired as of 22AUG22. Make permanent repair prior to next dry-dock/hull exam.
46 CFR 177.300(d)(1)(ii) - 705c
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 September 2022
Resolution: Temporary fix in place until vessel is hualed out at the end of the season and permanent repairs can be made.