09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Engine room breaker panel has exposed contacts for 300v breaker. Provide means to prevent accidental contact of exposed wires.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Installed cover to prevent electrical shock
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Enclosure for pilot house air conditioning unit destroyed leaving electrical hazards open to weather/contact. Replace enclosure as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 19 September 2024
Resolution: Replaced entire unit. GS
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Index of breaker loads do not meet the actual breakers loads. Provide proper labeling of breakers as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 11 January 2024
Resolution: New labels installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Dead end wires found in engine room overhead. Place dead ends inside and enclosure or remove wires from vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Dead end wires removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023
Resolved
The connections of flexible cable plugs and socket outlets must be designed to prevent unintended separation. Permanently installed extension cords found in vessel. Remove extension cords as required.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Extention cords removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Port and Starboard battery connections loose. Tighten battery connections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Battery terminals tightened
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 September 2023
Resolved
The following systems must be equipped with gauges at the machinery location - (1) Main engine lubricating oil pressure and main engine RPM (3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. Main engine and aux generators are not equipped with RPM gauges at the machinery location. Install RPM gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 11 January 2024
Resolution: Tachometers installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Fuel found leaking through aft 2 injectors of generators engine. Repair leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 11 January 2024
Resolution: Fuel leak repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Mast head light electrical wires burnt/melted. Replace damaged wire with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: damaged wire replaced with new
08 - Alarms › N/A - No Subsystem › General alarm
Issued 7 September 2023
Resolved
Each towing vessel must be fitted with a general alarm that has installed, in the engine room a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm. General alarm light missing. Install general alarm light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: General alarm light installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2023
Resolved
Each remote fuel shut off valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Description of fuel shut off valve remote operation missing. Label fuel shut off valves as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Fuel valves properly labeled
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 September 2023
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Flammable products found in engine room and deck room. Place flammable materials in flammable liquids locker or remove from vessel.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Flammable liquid products stored in approved locker
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 7 September 2023
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Rails missing fore and aft of vessel. Install rails or equivalent protection to prevent falls overboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 8 December 2023
Resolution: Railing installed as required.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 7 September 2023
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment is not being completed on this vessel. Conduct and document navigation assessments before getting underway.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Navigation assessments being completed
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 September 2023
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Accumulation of oil found in engine room bilge. Clean bilges and repair engine oil leaks to prevent further occurrence.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: All oil removed from bilges
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 September 2023
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Items in first aid kit expired. Replaced expired products with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Expired items replaced with new
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 September 2023
Resolved
Each lifebuoy on a towing vessel must be marked in block capital letters with the name of the vessel. Both lifebuoys at pilot house missing vessels name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Vessel name added to life rings
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 7 September 2023
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Watertight hatches missing label. Install required label to hatches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Labels added to all WTHs
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 September 2023
Resolved
Records of drills and instruction must be maintained in the TVR, official logbook. The record must include: (1) The date of the drill and instruction; (2) A description of the drill scenario and instruction topics; (3) The personnel involved. No records of drills provided. Provide records of drills to CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 8 December 2023
Resolution: Drills completed and logged in TVR as required.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 September 2023
Resolved
Individuals, who are not crewmembers, on board a towing vessel must receive a safety orientation prior to getting underway or as soon as practicable thereafter, to include: (a) The location, operation, and use of lifesaving equipment; (b) Emergency procedures; (c) Methods to notify crewmembers in the event of an emergency; and (d) Prevention of falls overboard. New crew member orientation not being completed. Complete training and provide documentation to CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: New crew member orientation added to Nav assessment
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 September 2023
Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10, Standard for Portable Fire Extinguishers. Portable fire extinguisher in deck room not properly mounted in bracket. Install portable fire extinguisher in mounted bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Fire extinguisher installed with approved bracket
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2023
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. Compressed air system utilized for control air has an unapproved connection utilizing flexible hoses. Remove modification and return to original configuration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Compressed air piping returned to origional condition.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 September 2023
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. No records for crews chemical testing provided. Provide chemical testing results as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 27 February 2024
Resolution: Provided proof of 5 part DOT drug testing
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022
Resolved
Each distribution panel or switchboard must have nonconductive mats or grating on the deck in front of each panel. No nonconductive mats or grating installed. Install nonconductive mats or grating.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 19 September 2024
Resolution: Replaced.GS
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022
Resolved
Three battery boxes located in the engine space were missing covers. Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Install battery box covers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 21 June 2022
Resolution: New battery boxes purchased