Records from 1986 to 2025. Most recent: inspection, 18 August 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 37
18 August 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8212392
25 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7942356
22 May 2023
COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7694164
22 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7483462
10 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7193576
26 June 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6725540
28 March 2018
Hull Examination · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6380104
17 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6126511
4 April 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5847296
26 March 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4822835
27 December 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3916612
18 March 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3698366
6 March 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3428573
21 March 2008
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3168766
12 March 2007
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2886195
19 April 2006
Simplified Stability Test · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2628233
20 February 2004
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2012830
21 March 2003
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1815180
14 August 2002
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1661556
24 October 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403483
20 February 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406873
20 December 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417007
12 August 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402698
12 August 1997
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451220
11 October 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1151957
8 November 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400257
17 August 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 875652
24 August 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460743
4 August 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447262
28 January 1993
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1140496
5 August 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422173
8 August 1991
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933635
9 August 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1218005
10 August 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1197590
6 October 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1197058
25 September 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010932
13 August 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320668
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 May 2023
Resolved
Fire extinguishers required on a vessel must be acceptable to the satisfaction of the [name withheld] extinguisher was out of service.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2023
Resolution: Verified they received fire extinguisher for vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 May 2023
Resolved
A vessel on lakes, bays, and sounds, or rivers route must carry 06 flares. All flares on vessel were expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2023
Resolution: Verified they received flares for vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 June 2019
Resolved
Fire Buckets are not properly labeled and two out of three are missing the lanyard
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2019
Resolved 3 July 2019
Resolution: VSL Master sent a photo of labeled fire buckets with lanyards
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 April 2017
Resolved
Provide recipt of certification of fire extinguishers.
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 28 March 2018
Resolution: Checked portable fire extinguishers for serviceing. All sat.
Lifesaving › Hand Flares › Expired
Issued 4 April 2016
Resolved
vessel had 4 expired flares onboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2016
Resolved 7 April 2016
Resolution: Vessel rep provided receipt to clear all outstanding items in their fleet.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 April 2016
Resolved
Extinguisher had not been serviced in the past year. Required vessel rep to prove extinguisher was satisfactorily serviced.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2016
Resolved 27 April 2016
Resolution: Vessel rep provided receipt to clear all outstanding items in their fleet.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 4 April 2016
Resolved
Vessel did not have required emergency instructions posted.
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 4 April 2016
Resolution: Vessel rep posted emergency instructions after they were shown the correct cite.
Documentation › Logs/Records › Logbook (official)
Issued 4 April 2016
Resolved
No drills were logged. required vessel rep to conduct and log monthly drills.
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 4 April 2016
Resolution: Conducted drills while onboard, and educted vessel rep on how to log drills, vessel rep started drill log prior to departure of the CGMI.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 April 2016
Resolved
lifejacket was condemned due to compromized buoyant material(about half of original volume remaining)
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 4 April 2016
Resolution: Vessel rep destroyed lifejacket, CGMI confirmed that the vessel still had it's minimum onboard.
Fire Fighting › Fire Bucket › Availability
Issued 26 March 2014
Resolved
Vessel was missing 3 fire fighting buckets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2014
Resolved 1 April 2014
Resolution: Operator provided reciept and pictures of new fire bukets onboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 26 March 2014
Resolved
Vessels B-1 extinguisher was not within pressure range and starting to corrode. Needs to be replaced with a new extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2014
Resolved 27 March 2014
Resolution: Owner provided proof of purchase of new extinguisher.
Lifesaving › Hand Flares › Expired
Issued 26 March 2014
Resolved
Vessel had 3 expired hand flares.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2014
Resolved 27 March 2014
Resolution: Owner provided proof of purchase of new hand flares.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 December 2010
Resolved
Wasted SOLAS approved reflective type on life jackets including child-size life jacket as needed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Resolution: Replaced approved reflective type on life jackets.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 27 December 2010
Resolved
Lack of two types of life jacket donning placard posted. Require to post all types of life jacket donning placards on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2010
Resolution: Posted two types of life jacket donning placards visible to all passengers.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 27 December 2010
Resolved
Lack of annual fire fighting certification for servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Resolution: Serviced fire extinguisher within correct time period.
Communications › Audible Communications › Horn/Whistle
Issued 6 March 2009
Resolved
No horn on vessel
Due 6 April 2009
Resolved 13 March 2009
Resolution: New air horn purchased
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 March 2009
Resolved
Fire extinguishers past due for service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2009
Resolution: Rcvd faxed confirmation that fire extinguishers had been serviced.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 12 March 2007
Resolved
Service all portable fire extinguishers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2007
Resolution: Sea Safety and Survival, Inc. serviced vessel''s portable fire extinguishers.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 March 2007
Resolved
Label lifejackets with vessel name.
Due 12 April 2007
Resolved 16 April 2007
Resolution: Lifejackes were labeled with vessel name.
Lifesaving › Hand Flares › Quantity
Issued 12 March 2007
Resolved
Provide 6 not expired distress signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2007
Resolution: Vessel representative stated distress flares had been puchased.
Stability › Severe Wind/Roll › General
Issued 18 April 2006
Resolved
Vessel did not pass simplified stability test.
Due 18 April 2006
Resolved 18 April 2006
Resolution: Reduced passengers allowed by three. Vessel passed the test with 420 pounds of reduced weight.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 20 February 2004
Resolved
Test and install fire extinguisher. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Completed repairs on fire extinguishers.
Lifesaving › Hand Flares
Issued 20 February 2004
Resolved
Provide and install 3 orange and 3 red flares on board. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Provided flares.
Lifesaving › Hand Flares
Issued 20 February 2004
Resolved
Stencil distress signal box LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Stenciled flare box.
Lifesaving › Lifejacket/PFD (General)
Issued 20 February 2004
Resolved
Label and number life jacket bins. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Label bins.
Lifesaving › Lifejacket/PFD (General)
Issued 20 February 2004
Resolved
Provide and mount life jacket donning placard. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Mounted placard.
Accommodation/Occupational Safety › Medical/First Aid
Issued 20 February 2004
Resolved
Provide and install first aid kit on board as per number of passengers on COI. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Mounted first aid kit.
Lifesaving
Issued 12 August 1997
Resolved
REPLACE ONE LIFERING.
Condition: Unknown
Due 12 August 1997
Resolved 13 August 1997
Lifesaving
Issued 12 August 1997
Resolved
PROVIDE TWO ADULT LIFE JACKETS.
Condition: Unknown
Due 12 August 1997
Resolved 13 August 1997
Lifesaving
Issued 12 August 1997
Resolved
REPLACE ALL OUTDATED DISTRESS FLARES.
Condition: Unknown
Due 12 August 1997
Resolved 13 August 1997