MAURY USCG vessel records
← All vessels

IT INFINITY

IT INFINITY is a offshore supply vessel. The Coast Guard has recorded 3 inspections since 2022, most recently in April 2025, along with 2 deficiencies — 1 with no resolution recorded —.

Records from 2022 to 2025. Most recent: inspection, 21 April 2025.

Built
Not recorded
Last inspected
21 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 April 2025
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2022–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9390549
1729474
Flag
BARBADOS
Maury page id
psix-1729474

Documentation record

Tonnage as PSIX records it5000 - Dead Weight, Metric Ton
4277 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

21 April 2025 PSC B · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8116414
15 June 2022 PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7476418
14 June 2022 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7477583

Deficiency record · 2

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 28 April 2025 Resolved
Every inflatable life raft shall be serviced a intervals not exceeding 12 months. PSCO witnessed 06 liferafts that were due for servicing in February 2025.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: The vessel provided pictures proof of the new liferafts properly configured on deck with new servicing and expiration dates on the labels.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 April 2025 No resolution recorded
Machinery spaces shall be adequately ventilated to ensure an adequate supply of air maintained. The vessel underwent a conversion to a cable laying vessel and the rerouting of ventilation is not according to solas II-I/35 requirements.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.