MAURY USCG vessel records
← All vessels

EMS TRADER

EMS TRADER is a 2000 freight ship. The Coast Guard has recorded 29 inspections since 2016, most recently in February 2020, along with 20 deficiencies and 3 operational controls.

Records from 2016 to 2020. Most recent: inspection, 9 February 2020.

Built
2000
Last inspected
9 February 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 February 2020
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9213105
Flag
PORTUGAL
Maury page id
psix-17329

Documentation record

Tonnage as PSIX records it44107 - Displacement, Metric Ton
33917 - Dead Weight, Metric Ton
25535 - Convention (Subpart B), Gross Ton
12454 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

9 February 2020 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6905512
6 January 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6883601
5 December 2019 ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6867735
22 August 2019 Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6791246
23 July 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6759213
21 May 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6689815
10 April 2019 Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6659755
15 March 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6643116
26 February 2019 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6638585
12 February 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6624746
6 February 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6621096
6 February 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6621357
19 October 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6564631
17 August 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6515391
29 June 2018 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6459539
29 June 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6459944
27 January 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6344613
29 December 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6330098
15 November 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6307641
27 August 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6252929
26 August 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6251951
26 August 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6254812
14 July 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6209038
13 May 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6145276
10 March 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6102428
21 February 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6090797
3 November 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6034443
10 August 2016 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5968247
8 January 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5794028

Deficiency record · 20

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 December 2019 Resolved
Before ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Rescue boat ignition coil is inoperable; rescue boat motor cannot be started. 74SOLAS(14)III/20.2 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 December 2019
Resolution: Received class report attesting to the functionality of the rescue boat engine.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 December 2019 Resolved
Before ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Freefall lifeboat steering cable found damaged by crew on 02DEC19; crew removed cable and steering is only capable via emergency tiller. Freefall lifeboat emergency steering tiller position does not allow operator visibility through the lifeboat windows. 74SOLAS(14)III/20.2 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 December 2019
Resolution: Received class report attesting to the replacement of the lifeboat steering capable and the full functionality of the lifeboat steering system.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 5 December 2019 Resolved
Oil filtering equipment shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. PSCO conducted operational test of oily water separator and identified OWS would not send effluent to overboard valve without fresh water line open to oil content meter. MARPOL Annex I/14.6 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2019
Resolved 6 January 2020
Resolution: Vessel's Master submitted Class Report attesting to satisfactory replacement of pump and successful tests after the repair.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 December 2019 Resolved
Doors required to be self-closing shall not be fitted with hold-back arrangements. Emergency escape door in generator room and steering gear entrance had unapproved hold-back arrangements. 74SOLAS(01)II-2/47.2 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 December 2019
Resolved 5 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 December 2019 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All life-saving appliances prescribed in this part shall be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the organizations. Freefall lifeboat retro-reflective tape on the port side is significantly deteriorated and no longer reflective. 74SOLAS(14)III/34 ref LSA Code 1.2.2.7 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 December 2019
Resolved 5 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 April 2019 Resolved
The machinery shall be of a design and construction adequate for the service intended and shall be installed and protected to reduce any danger to persons onboard. #1 Generator is leaking from the crankcase seal. The crew has a drum under the machinery with hoses draining oil.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2019
Resolved 11 April 2019
Resolution: Crew dismantled the Aux. engine No .1 crankcase vent and cleared same ventilation pipe of oil, dirt, debris, etc. Once engine started and ran for DNV GL Surveyor there is no more oil leakage at labyrinth seal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 April 2019 Resolved
The main source of electrical power shall consist of atleast two generating sets. Only one generator is online of the three onboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2019
Resolved 11 April 2019
Resolution: All engines running under electrical load thus SOLAS regulations are now met onboard with vessel own complement of electrical generating machinery.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 April 2019 Resolved
Flammable liquid lockers shall be protected by an appropriate fire-extinguishing arrangement by the administration. Oil samples are being stored in steering gear space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2019
Resolved 11 April 2019
Resolution: MARPOL Samples removed to appropriate fire protected space. Steering gear machienry space is free of MARPOL samples.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2019 Resolved
Cooling leaking water Chapter I Reg IIA. The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 11 April 2019
Resolution: Vessel crew has made temporary repairs to leaking central SW cooler. Permanent repair is still need onboard, Supt. Engineer will order shore spares.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 February 2019 Resolved
Not withstanding the provisions of paragraph 1.1, any cargo space in a ship engaged in the carriage of dangerous goods shall be provided with a fixed gas fire extinguishing system complying with the provisions if regulation 5. Vessel is unable to discharge CO2 into cargo hold 4. The CO2 discharge system is controlled by a 3 way valve that has seized in a manner that does not allow the vessel to discharge CO2 in the event of a fire. 74SOLAS(01)II-2/53.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 21 May 2019
Resolution: Due date changed to meet condition of class. See attached class report. // Vessel submitted class report attesting to replacement of 3-way valve. Deficiency cleared. See attached class report.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 February 2019 Resolved
All other types of cargo spaces shall be fitted with either a fixed fire detection and fire alarm system complying with the requirements of regulation 13 or a sample extraction smoke detection system complying with requirements of regulation 13-1. Smoke extraction detection system for #4 cargo hold is not functioning due to seized valve. System has alarmed 10 times in 3 days. 74SOLAS(01)II-2/54.2.3
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 7 February 2019
Resolved 8 February 2019
Resolution: Class report received. Sensor replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 7 February 2019 Resolved
All valves and shell fittings required by this regulation shall be of steel, bronze, or other approved ductile material. All pipes to which this regulation refers shall be of steel or other equivalent material. There are 2 soft patches on the seawater discharge piping for the main engine cooling system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 15 March 2019
Resolution: See attached class report.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 7 February 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on-board. Received report that the vessel grounded while at Penn Terminals on 06FEB2019. Provide Classification Society report which identifies section of vessel that grounded, and attests to condition of hull and internal structure. 74SOLAS(01)I/11
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 15 March 2019
Resolution: See attached class report.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 6 February 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on-board. Vessel reported a loss of power, steering, propulsion while underway in the Delaware River. The following is required: a report from the Recognized Organization (RO) detailing the cause of the failure, the corrective actions taken, and attesting to the full functionality of the associated equipment.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2019
Resolved 7 February 2019
Resolution: Received class report. Item replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 6 February 2019 Resolved
74SOLAS (14) IX/3.1 & ISM CODE PART A/10.2.2 50AC THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN ACCORDANCE WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. THE MASTER WAS UNAWARE THAT THE CO2 FIRE SUPPRESSION SYSTEM FIR THE NUMBER 4 CARGO HOLD WAS NON FUNCTIONING AND THE VESSEL DID NOT COMPLY WITH THE NONCONFORMITY REPORTING REQUIREMENTS FOR TEO MAJOR SYSTEMS. AN AUDIT IS RECOMMENDED TO BE CONDUCTED WITHIN 30 DAYS BY THE FLAG STATE OR RO TO DETERMINE WHETHER THE SHIP IS OPERATING IN ACCORDANCE WITH THE ISM CODE. PROVIDE DECISION TO THE USCG WITHIN 30 DAYS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 15 March 2019
Resolution: See attached class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019 Resolved
74 SOLAS (14) I/11(a) 16AC THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE LUBE OIL COOLING SYSTEM ON THE #3 GENERATOR HAS A WATER LEAK. SEVERAL DROPS EVERY SECOND.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 26 February 2019
Resolution: Coast Guard examiner obeserved a replacement lube oil cooler that confirms class report for number 3 generator and rectification of leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019 Resolved
74SOLAS (14) I/11(a) 16AC THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE SEAWATER/FRESH WATER COOLING SYSTEM FOR THE MAIN ENGINE HAS A WATER LEAK IN VICINITY OF PLATE COOLER. APPROXIMATELY 5-10 DROPS EVERY SECOND. THERE IS EVIDENCE ON THE SURROUNDING DESK THAT IS AN ONGOING ISSUE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 26 February 2019
Resolution: Coast Guard examiner confirmed class report that repairs and rectification of the leak on the No. 2 LT cooler (M.E. freshwater cooler) have been made.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 February 2019 Resolved
74SOLAS(01)II-2/15.2 10C IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. EXCESSIVE OIL AND RAGS WERE FOUND WRAPPED AROUND PIPING AND MACHINERY IN THE PURIFYING SPACE.
Action required: 10 - Deficiency Rectified
Due 6 February 2019
Resolved 6 February 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 February 2019 Resolved
74SOLAS (01) II-2/46.1 10C STAIRWAYS WHICH PENETRATE ONLY A SINGLE DECK SHALL BE PROTECTED AT LEAST AT ONE LEVEL BY AT LEAST "B-0" CLASS DIVISIONS AND SELF-CLOSING DOORS. STAIRWAYS AND LIFT TRUNKS WHICH PENETRATE MORE THAN A SINGLE DECK SHALL BE SURROUNDED BY AT LEAST "A-0" CLASS DIVISIONS AND BE PROTECTED BY SELF-CLOSING DOORS AT ALL LEVELS. 03 SELF-CLOSING DOORS IN THE MAIN LADDER WELL DID NOT FULLY CLOSE.
Action required: 10 - Deficiency Rectified
Due 6 February 2019
Resolved 6 February 2019
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 6 February 2019 Resolved
74SOLAS(04)II-1/29.10 10C A MEANS OF COMMUNICATION SHALL BE PROVIDED BETWEEN THE NAVIGATION BRIDGE AND THE STEERING GEAR COMPARTMENT. THE PHONE IN THE STEERING GEAR ROOM WAS NOT OPERATIONAL.
Action required: 10 - Deficiency Rectified
Due 6 February 2019
Resolved 6 February 2019

Ownership record