Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it36412 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 4
4 June 2026Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8466231
26 March 2026Deficiency Check · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8332231
17 March 2026Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8327240
27 June 2022PSC A
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7489024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 26 March 2026Resolved
PSCO observed unapproved heat detection testing equipment. Crew initially used proper testing equipment, then utilized an unapproved heat gun.
Request internal ISM audit within 90 days for the purpose of fire detection testing methodology.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2026
Resolved 4 June 2026
Resolution: Received documentation of the completed internal audit
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 March 2026Resolved
PSCO observed crew using unapproved device (heat gun) to test heat detection system in engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2026
Resolution: Received class report from class NKK attesting that vessel Master provided training to crew on use of approved smoke and heat detector tester.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.