Records in 2022. Most recent: inspection, 18 July 2022.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 July 2022
Resolved
The machinery shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts and other hazards. PSCO observed fuel leak on #1 booster pump servicing generators in purifier room. Leaking also observed on booster #2. 74 SOLAS (20) II-1/26.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 July 2022
Resolution: Received class report attesting to repairs of both booster pumps.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 July 2022
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed lack of maintenance and testing of smoke and heat detectors. 74 SOLAS (20) II-2/14.2.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2022
Resolution: Received class report as well as report from GFS detailing a complete inspection and testing of the installed fire fighting system onboard the vessel.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 18 July 2022
No resolution recorded
EXCEPT AS SPECIFIED, ANY SHIP OF 10,000 GT AND ABOVE SHALL BE FITTED WITH OIL FILTERING EQUIPMENT. INOPERABLE OWS SYSTEM.
MARPOL I/14.2
Action required: 50 - Rectify deficiencies w/in 30 days
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 18 July 2022
No resolution recorded
THE PERSON IN CHARGE OF A VESSEL EQUIPPED WITH BALLAST TANKS THAT OPERATES IN THE WATERS OF THE U.S. ENSURES THE BWMS IS PROPERLY MAINTAINED WITH ALL MANUFACTURER SPECIFICATIONS. VESSEL'S BWMS IS INOPERABLE.
33CFR151.2025(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 18 July 2022
No resolution recorded
A SHIP OF 300+ GT MUST HAVE A FIXED CONTAINER OR ENCLOSED DECK AREA UNDER OR AROUND EACH FUEL OIL OR BULK LUBRICATING OIL TANK VENT, OVERFLOW, AND FILL PIPE. PSCO OBSERVED DRAIN PLUGS ON COAMINGS ARE MISSING OR IMPROPERLY INSTALLED ON ALL CATCHMENT SYSTEMS.
33CFR155.320(a)
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 18 July 2022
Resolved
CYLINDERS MUST BE SECURED AND WHEN NOT IN USE, MUST BE STOWED IN A RACK IN AN UPRIGHT POSITION. PSCO OBSERVED NITROGEN CYLINDERS IN AN UNSECURED POSITION IN THE STEERING GEAR ROOM.
46CFR147.60(b)(1)
Action required: 10 - Deficiency Rectified
Resolved 18 July 2022
Resolution: Rectified during inspection.