Records from 2022 to 2026. Most recent: inspection, 28 January 2026.
Inspection history · 7
28 January 2026
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8301925
9 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8108904
17 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8095032
30 May 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7922953
11 March 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7877022
13 March 2023
Initial Certification · Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7647193
1 June 2022
Plan Review "T" Boat · Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7497500
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 April 2025
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”.
Watertight container was not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 25 April 2025
Resolution: O/O sent Sector Charleston pictures of the words "Distress Signals" marked on the side of the side of the watertight box containing flares.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 April 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
Pain medication in vessel first aid kit is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 25 April 2025
Resolution: O/O sent Sector Charleston a picture of newly purchased and non-expired pain medication.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 April 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation.
Waterlight was not operable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 25 April 2025
Resolution: O/O sent Sector Charleston a picture of the waterlight being operable.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 March 2024
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10.
03 Portable fire extinguishers require an annual inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2024
Resolved 17 March 2024
Resolution: O/O emailed servicing pictures and receipts for 03 fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 March 2024
Resolved
A vessel must carry one floating waterlight.
Floating waterlight would not illuminate.
*Vessel is limited to daytime operations.
Action required: 705 - Other - as specified
Resolved 19 March 2024
Resolution: Vessel owner replaced required waterlight and showed proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 March 2024
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals and Three hand orange smoke distress signals.
Vessel did not have required amount of flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2024
Resolution: O/O provided picture of required flares installed on the vessel.