Records from 1989 to 2020. Most recent: inspection, 25 September 2020.
Documentation record
Registered dimensions (L × B × D)53.5 ft × 24.0 ft × 5.8 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUN CONTRACTORS INC · HARVEY, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
25 September 2020
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7068472
21 February 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6358919
25 March 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5841682
16 March 2016
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5834588
12 August 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5213935
14 August 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4960742
9 November 2010
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3888223
17 March 2009
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3435091
4 April 2008
Periodic Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3195609
11 October 2007
Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3077826
22 March 2007
Administrative Inspection · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2893420
12 October 2006
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2799160
13 December 2005
COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2550452
16 December 2004
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2261127
16 March 2004
Internal Structural Exam · Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2025767
20 February 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1747572
14 March 2002
Annual Inspection · Examination of Repairs · Hull Examination
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1495073
21 October 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388929
28 February 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 723148
14 October 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212617
14 October 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368875
23 September 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364416
14 February 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425873
21 December 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353838
8 December 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877389
8 December 1994
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387634
13 December 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 849365
6 December 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399945
23 October 1992
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472391
2 September 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249329
11 March 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 958709
25 November 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 956110
3 October 1990
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 906949
3 October 1990
Deficiency Check · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1226093
10 July 1990
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 931929
29 January 1990
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 903590
30 October 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1236054
5 October 1989
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1235814
Electrical › Electric Generation Source (service) › Generator
Issued 25 March 2016
No resolution recorded
Both generator sets on the vessel are old detroits and leaking oil. Generators need windings cleaned prior to next annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2017 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 March 2016
Resolved
Outlet box broken in wireline room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 4 April 2016
Resolution: Outlet cover added.
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 March 2016
Resolved
Fuel shut off not labeled.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 4 April 2016
Resolution: Fuel Shutoff labeled.
Engineering › Steering Gear System › Hydraulic Hose
Issued 25 March 2016
Resolved
03 hydraulic hoses were wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 4 April 2016
Resolution: Hoses replaced.
Fire Fighting › Fire Hoses › Material
Issued 12 August 2015
Resolved
The fire hoses were not labeled with the vessel name.
Due 19 August 2015
Resolved 12 August 2015
Resolution: Labeled both hoses, all sat.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 August 2015
Resolved
The antenna bracket was missing and antenna was secured with duct tape. Install proper bracket.
Due 25 August 2015
Resolved 12 August 2015
Resolution: Installed bracket, all sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 August 2015
Resolved
Drills were not logged at the proper intervals.
Due 12 August 2015
Resolved 12 August 2015
Resolution: Conducted all three drills in the presence of a Marine Inspector, all sat.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 August 2015
Resolved
The life saving maintenance log was not updated.
Due 12 August 2015
Resolved 12 August 2015
Resolution: Inspected life saving and found two deficiencies, vessel corrected all sat. Instructed Master on importance of proper log keeping.
Engineering › Bilge Water Management System › Valve
Issued 20 February 2003
Resolved
Replace bilge valve overboard discharge handle and ensure proper operation of valve.
Due 21 February 2003
Resolved 21 February 2003
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 20 February 2003
Resolved
Service Type II MSD and train crewmembers in proper maintenance procedures.
Condition: Improper/Lack of Maintenance
Due 21 February 2003
Resolved 21 February 2003
Documentation › Markings/Placards
Issued 20 February 2003
Resolved
Stencil fire axe with vessel name.
Due 21 February 2003
Resolved 21 February 2003
Lifesaving › Visual Distress Signals (General) › Condition
Issued 20 February 2003
Resolved
Replace bulb globe on water light.
Due 20 February 2003
Resolved 20 February 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 February 2003
Resolved
Provide proof of servicing for B-II portable extinguisher mounted on mess deck bulkhead.
Due 21 February 2003
Resolved 21 February 2003
Lifesaving
Issued 21 October 1999
Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District Policy Ltr. dated 12NOV98 "Rescue Boat Requirements for Offshore Supply Vessels" to thesatisfaction of the attending Marine Inspector.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Unknown
Issued 23 September 1997
Resolved
PROVIDE AN UPDATED STABILITY LTR TO REFLECT REVISIONS MADE TO OP MAN.
Condition: Unknown
Due 23 September 1997
Resolved 23 September 1997
Documentation
Issued 23 September 1997
Resolved
UPDATE OP MANUAL TO REFLECT THE WEIGHT CHANGES AS A RESULT OF CRANE REPLACEMENT. OP MANUAL MUST BE STAMPED APPROVED. A ONE SHORT TON REDUCTION OF DECK CARGO IS TO BE OBSERVED UNTIL OP MANUAL IS UPDATED/APPROVED.
Condition: Unknown
Due 23 September 1997
Resolved 23 September 1997
Deck/Cargo
Issued 25 November 1991
Resolved
MAKE PERMANENT REPAIRS TO CRANE, AND CONDUCT LOAD TEST.
Condition: Unknown
Due 25 November 1991
Resolved 25 November 1991
Fire Fighting
Issued 30 October 1989
Resolved
A THROUGH HULL FITTING WITH AN APPROPRIATE ISOLATION VALVE MUST BE INSTALLED ON THE CECIL HARRIS TO PROVIDE SEA WATER SUCTION FOR THE FIRE SYSTEM WHILE THE VESSEL IS IN THE FLOATING MODE OF OPERATION.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Construction/Loadline
Issued 30 October 1989
Resolved
A BILGE SUCTION ISOLATION VALVE FOR THE PORT AND STARBOARD FORWARD VOIDS MUST BE LOCATED IN THOSE COMPARTMENTS, ADDITIONALLY THEY MUST BE FITTED WITH A REMOTE ACTIVATION DEVICE, OR REACH RODS FROM THE MAIN DECK.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Fire Fighting
Issued 30 October 1989
Resolved
PROVIDE A MEANS FOR AUTOMATIC CUT OUT FOR THE ENGINE ROOM EXHAUST FANS, IE:THE SHIPS SERVICE GENERATORS WHEN THE FIXED CO2 SYSTEM IS ACTIVATED.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Documentation
Issued 5 October 1989
Resolved
PROVIDE A U. S. COAST GUARD APPROVED OPERATIONS MANUAL ON BOARD.
Condition: Unknown
Due 5 October 1989
Resolved 5 October 1989
Documentation
Issued 5 October 1989
Resolved
PROVIDE AND POST A STABILITY LETTER ON BOARD FOR THE CECIL HARRIS.
Condition: Unknown
Due 5 October 1989
Resolved 5 October 1989