APOLLO 14

APOLLO 14 is a 1979 offshore supply vessel. The Coast Guard has recorded 4 inspections since 2016, most recently in September 2020, along with 4 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2020. Most recent: inspection, 25 September 2020.

Built
1979
Last inspected
25 September 2020
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WCP7366
173803
Flag
UNITED STATES
Maury page id
psix-173803

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspections, by type

…past their stated due date1
Years with a record 3 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)53.5 ft × 24.0 ft × 5.8 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUN CONTRACTORS INC · HARVEY, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

25 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7068472
21 February 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6358919
25 March 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5841682
16 March 2016 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5834588

Deficiency record · 4

Electrical › Electric Generation Source (service) › Generator
Issued 25 March 2016 No resolution recorded
Both generator sets on the vessel are old detroits and leaking oil. Generators need windings cleaned prior to next annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2017 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 March 2016 Resolved
Outlet box broken in wireline room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 4 April 2016
Resolution: Outlet cover added.
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 March 2016 Resolved
Fuel shut off not labeled.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 4 April 2016
Resolution: Fuel Shutoff labeled.
Engineering › Steering Gear System › Hydraulic Hose
Issued 25 March 2016 Resolved
03 hydraulic hoses were wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 4 April 2016
Resolution: Hoses replaced.