Records from 2022 to 2025. Most recent: inspection, 30 November 2025.
Inspection history · 6
30 November 2025
PSC A · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8274282
2 December 2024
COC-CVE Annual
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8040632
9 March 2024
PSC B · Administrative Inspection · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7874287
24 October 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7813633
15 September 2023
COC-CVE Initial
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7791302
2 November 2022
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 7588044
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 November 2025
Resolved
THE MAIN INLETS AND OUTLETS OF VENTILATION SYSTEMS SHALL BE CAPABLE OF BEING CLOSED FROM OUTSIDE THE SPACES BEING VENTILATED. THE MEANS OF CLOSING SHALL BE EASILY ACCESIBLE AS WELL AS PROMINENTLY AND PERMANENTLY MARKED AND SHALL INDICATE THE OPERATING POSITION OF THE CLOSING VALVES. PSCO OBSERVED FIRE DAMPER AT DECK 9 ZONE 3 PORTSIDE INOPERABLE. IN ADDITION, THE LABEL FOR THE FIRE DAMPER WAS PAINTED OVER.
74SOLAS(2020)
II-2 / 10.4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2025
Resolution: Corrected prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2025
Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED EXCESSIVE HYDRAULIC OIL LEAK FROM THE SIDE DOOR SYSTEM HYDRAULIC POWER PACK.
74SOLAS(2020)
II-2 / 4.1.1
Action required: 15 - Rectify deficiencies by next port
Resolved 30 November 2025
Resolution: Corrected prior to completion of the exam.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 November 2025
Resolved
A FIXED FIRE EXTINGUISHING SYSTEM, REQUIRED BY THIS CHAPTER SHALL COMPLY WITH THE PROVISIONS OF THE FSS CODE. A GUAGE INDICATING THE PRESSURE IN THE SYSTEM SHALL BE PROVIDED AT EACH SECTION STOP VALVE AND AT A CENTRAL STATION. PSCO OBSERVED SECTION PRESSURE GUAGES A11-4 & A14-2 INOPERABLE.
74SOLAS(2020) II-2 / 10.4.1.1
FSS CODE 8.2.4.2.5
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 November 2025
Resolution: Corrected priot to completion of the exam.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 November 2025
Resolved
THE MAIN INLETS AND OUTLETS OF VENTILATION SYSTEMS SHALL BE CAPABLE OF BEING CLOSED FROM OUTSIDE THE SPACES BEING VENTILATED. THE MEANS OF CLOSING SHALL BE EASILY ACCESIBLE AS WELL AS PROMINENTLY AND PERMANENTLY MARKED AND SHALL INDICATE THE OPERATING POSITION OF THE CLOSING VALVES. PSCO OBSERVED STARBOARD AFT PURIFIER ROOM FIRE DAMPER INDICATOR LIGHT WAS INOPERABLE.
74SOLAS(2020) II-2 / 9.7.1.5.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 November 2025
Resolution: Corrected prior to completion of the exam.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 9 March 2024
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. 02 stairway guides on deck 14 and 15 were not familiar with the ship's emergency procedures during the abandon ship scenario.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2024
Resolution: Crewmembers received training prior to the PSCO's leaving.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 March 2024
Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. 02 mess cooks in the galley on deck 5 were not familiar with the location of fire extinguishers nor the operation of the installed fire suppression system.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2024
Resolution: Crewmembers received training prior to the PSCO's leaving.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 March 2024
Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. 02 crewmembers engaged in bunkering operations on the stbd side bunkering station were unfamiliar with the operation of the fixed local fire suppression system or the nearest manual call point.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2024
Resolution: Crewmembers received training prior to the PSCO's departing.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 9 March 2024
Resolved
Each passenger stateroom and crew cabin shall be equipped with entry doors that include peep holes or other means of visual identification. Multiple peep holes on crew cabin doors on deck 6 were broken or removed. 46 CFR 3507 (a)(1)(B)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2024
Resolution: Vessel sent proof of repair of the peep holes.