MAURY USCG vessel records
← All vessels

ALLURA

ALLURA is a passenger vessel (inspected). The Coast Guard has recorded 4 inspections since 2025, most recently in March 2026, along with 6 deficiencies.

Records from 2025 to 2026. Most recent: inspection, 21 March 2026.

Built
Not recorded
Last inspected
21 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 March 2026
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2025–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9876969
V7A6860
1738541
Flag
MARSHALL ISLANDS
Maury page id
psix-1738541

Documentation record

Tonnage as PSIX records it5324 - Dead Weight, Ton
37521 - Displacement, Ton
37424 - Convention (Subpart B), Net Ton
67901 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

21 March 2026 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8329486
14 October 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8251505
27 September 2025 PSC A · COC-CVE Initial
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8242282
3 February 2025 COC-CVE Initial Prep · COC-CVE Initial
Administrative · Activities Europe · Activity 8073529

Deficiency record · 6

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 21 March 2026 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. PSCOs observed an issue with both rescue boat's emergency steering that affected operation. For emergency steering to work there is a butterfly nut that needs to be removed for proper operation, and this bolt/nut was installed upside-down on each rescue boat. 74 SOLAS 20 III/34 LSA Code 1.2.2.7 15ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 21 March 2026
Resolution: Verified corrected during the exam by PSCOs.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 March 2026 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers/crew to identify the routes of escape and readily identify the escape exits. PSCOs observed furniture and equipment blocking low location lighting in the hospital. 74 SOLAS 20 II-2/13.3.2.5.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2026
Resolved 21 March 2026
Resolution: Verified corrected during the exam by PSCOs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 March 2026 Resolved
Openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCOs observed FD 5.2.08 unable to fully close. 74 SOLAS 20 II-2/9.4.1.1.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2026
Resolved 21 March 2026
Resolution: Verified corrected during the exam by PSCOs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 March 2026 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. PSCOs observed a self closing B15 door propped open with a wedge. 74 SOLAS 20 II-2/9.4.1.2.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2026
Resolved 21 March 2026
Resolution: Verified corrected during the exam by PSCOs.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 March 2026 Resolved
The administration shall ensure that such lighting or photoluminescent equipment has been evaluated, tested, and applied in accordance with the Fire Safety Systems Code. Any required Low-location lighting systems shall be approved by the Administration. PSCOs observed a corridor more than 2 meters wide missing low-location lighting on one side IAW IMO A. 752 (18). 74 SOLAS 20 II-2/13.3.2.5.1 FSS Code 11.2.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2026
Resolved 21 March 2026
Resolution: Verified corrected during the exam by PSCOs.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 September 2025 Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed wheelchairs stowed in stairway landings impeding means of escape. 74 SOLAS 20 II-2/13.1.2 10 abc
Action required: 10 - Deficiency Rectified
Due 27 September 2025
Resolved 27 September 2025
Resolution: The wheelchairs were removed from the stowed positions.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.