11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 21 March 2026
Resolved
All life-saving appliances and arrangements shall comply
with the applicable requirements of the Code. PSCOs
observed an issue with both rescue boat's emergency
steering that affected operation. For emergency steering to
work there is a butterfly nut that needs to be removed for
proper operation, and this bolt/nut was installed
upside-down on each rescue boat.
74 SOLAS 20 III/34 LSA Code 1.2.2.7
15ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 21 March 2026
Resolution: Verified corrected during the exam by PSCOs.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 March 2026
Resolved
The means of escape, including stairways and exits, shall be
marked by lighting or photoluminescent strip indicators
placed not more than 300 mm above the deck at all points of
the escape route, including angles and intersections. The
marking must enable passengers/crew to identify the
routes of escape and readily identify the escape exits.
PSCOs observed furniture and equipment blocking low
location lighting in the hospital.
74 SOLAS 20 II-2/13.3.2.5.1
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2026
Resolved 21 March 2026
Resolution: Verified corrected during the exam by PSCOs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 March 2026
Resolved
Openings shall be provided with permanently attached
means of closing which shall be at least as effective for
resisting fires as the divisions in which they are fitted.
PSCOs observed FD 5.2.08 unable to fully close.
74 SOLAS 20 II-2/9.4.1.1.1
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2026
Resolved 21 March 2026
Resolution: Verified corrected during the exam by PSCOs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 March 2026
Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. PSCOs observed a self closing B15 door propped open with a wedge.
74 SOLAS 20 II-2/9.4.1.2.1
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2026
Resolved 21 March 2026
Resolution: Verified corrected during the exam by PSCOs.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 March 2026
Resolved
The administration shall ensure that such lighting or
photoluminescent equipment has been evaluated, tested,
and applied in accordance with the Fire Safety Systems
Code. Any required Low-location lighting systems shall be
approved by the Administration. PSCOs observed a
corridor more than 2 meters wide missing low-location
lighting on one side IAW IMO A. 752 (18).
74 SOLAS 20 II-2/13.3.2.5.1
FSS Code 11.2.1
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2026
Resolved 21 March 2026
Resolution: Verified corrected during the exam by PSCOs.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 September 2025
Resolved
The following functional requirements shall be met: escape
routes shall be maintained in a safe condition, clear of
obstacles. PSCO observed wheelchairs stowed in stairway
landings impeding means of escape.
74 SOLAS 20 II-2/13.1.2
10 abc
Action required: 10 - Deficiency Rectified
Due 27 September 2025
Resolved 27 September 2025
Resolution: The wheelchairs were removed from the stowed positions.