Records from 1990 to 2015. Most recent: operational control imposed, 14 September 2015.
Documentation record
Registered dimensions (L × B × D)64.0 ft × 24.0 ft × 4.4 ft
Registered tonnagegross 76 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC · CAENARVON, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
14 September 2015
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5717679
28 August 2015
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5228449
16 October 2014
Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5006521
5 January 2012
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4218293
18 March 2010
Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3697488
15 July 2009
Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3534601
18 March 2008
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3166937
18 September 2006
Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2781400
22 March 2006
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2607363
28 September 2004
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2206212
27 October 2003
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1935072
3 April 2002
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1482614
21 December 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462044
25 November 1998
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430616
22 January 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467036
20 August 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1118699
27 November 1996
Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 873184
27 November 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377979
5 December 1995
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 759735
29 August 1995
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 198944
5 December 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 130105
5 December 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 229692
27 October 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1138853
7 February 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 956905
4 February 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 945424
22 January 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1212529
8 January 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 903173
20 November 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211132
15 August 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230637
28 June 1990
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 930067
Communications › Radio Communications › Emergency Source of Power
Issued 14 September 2015
Resolved
Radio did not work on E-Power.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2015
Resolved 15 September 2015
Resolution: Corrected
Construction/Loadline › Structures › Machinery Space Opening
Issued 14 September 2015
Resolved
Hatches that open up to engine room were not water tight and sunlight shining through the gaskets when closed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2015
Resolved 15 September 2015
Resolution: New gaskets installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 September 2015
Resolved
E-Light in port engine room did not work.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2015
Resolved 15 September 2015
Resolution: Fixed.
Engineering › Bilge Water Management System › Hose
Issued 14 September 2015
Resolved
Flexable Connection in Bilge Piping was dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2015
Resolved 15 September 2015
Resolution: Connection/hose replaced
Construction/Loadline › Structures › Ventilators
Issued 14 September 2015
Resolved
Venilation trunk was wasted and missing making it impossible to be closed in case of fire.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2015
Resolved 16 September 2015
Resolution: Vessel welded a plate on truck to make it able to be closed in case of fire.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 28 August 2015
Resolved
Vessel not ready for inpsection, complete Annual Inspection Prior to Sail
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2015
Resolved 14 September 2015
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 March 2010
Resolved
Lable all emergency lights.
Action required: 705 - Other - as specified
Resolved 1 April 2010
Electrical › Electric Supply System (service) › Cable
Issued 18 March 2010
Resolved
Provide metal cable supports spaced no more than 24 inches apart for all cables and wires in engine room.
Action required: 705 - Other - as specified
Resolved 1 April 2010
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 March 2010
Resolved
Provide up to date Tide Tables, light lists, and coast pilot publications.
Action required: 705 - Other - as specified
Resolved 1 April 2010
Lifesaving › Lifefloat › Markings
Issued 18 March 2008
Resolved
Properly mark vsl's name on new 8-man lifefloat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 18 March 2008
Resolved
Repair or renew port MDE voltage gauge at the main control station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 March 2008
Resolved
Install insulation/lagging on port MDE exhaust manifold piping.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2015
Resolved 14 September 2015
Electrical › Electric Supply System (service) › Cable
Issued 22 March 2006
Resolved
Remove armor jacket from shore tie (vessel side) or renew cable. Existing armor jacket is frayed and will eventually "barb" someone.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: Armor jacket removed.
Engineering › Fuel Oil Service System › Hose
Issued 22 March 2006
Resolved
Renew f/o service hoses that are worn, cracked, spongy, on both MDE's.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: All new fire resistant Parker hoses installed.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 22 March 2006
Resolved
Provide compass deviation table.
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 18 March 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 22 March 2006
Resolved
repair leaking "T" fitting in piping between port and starboard fuel storage tanks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2006
Resolution: New "T" installed, leak corrected.
Construction/Loadline › Hull › Stringer
Issued 3 April 2002
Resolved
A portion of the starboard quarter deck plate was found to be wasted. A 18" X18" insert was installed.
Condition: Improper/Lack of Maintenance
Due 3 April 2002
Resolved 3 April 2002
Fire Fighting › Fire Hoses
Issued 3 April 2002
Resolved
Two fire hoses burst during hydro test.
Condition: Unknown
Due 3 April 2002
Resolved 3 April 2002
Documentation
Issued 27 November 1996
Resolved
PROVIDE ON BOARD A STABILITY LETTER ISSUED BY USCG MARINE SAFETY CENTER (GMSC).
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 September 2015
Documentation
Issued 27 November 1996
Resolved
PROVIDE ON BOARD A USCG APPROVED OPERATING MANUAL; PENDING APPROVAL, VESSELMAY OPERATE WITH CURRENT OPERATING MANUAL.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 September 2015
Documentation
Issued 28 June 1990
Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C., VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING OPERATING MANUAL UNTIL THE U.S. COAST GUARD APPROVED MANUAL ISRECEIVED.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 August 2015
Navigation
Issued 28 June 1990
Resolved
CALIBRATE MAGNETIC COMPASS AND SUBMIT DEVIATION TABLE TO [name withheld].
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 June 2015
Documentation
Issued 28 June 1990
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER,WASHINGTON, D.C. FOR REVIEW AND APPROVAL.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 September 2015
Documentation
Issued 28 June 1990
Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM 1 TO THE COGNIZANT OCMI.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 September 2015
Documentation
Issued 28 June 1990
Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.: INBOARD AND OUTBOARD PROFILES, LEG STRUCTURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 September 2015