Records from 1991 to 2005. Most recent: inspection, 28 March 2005.
Documentation record
Registered dimensions (L × B × D)64.0 ft × 24.0 ft × 4.4 ft
Registered tonnagegross 76 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC · CAERNARVON, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
28 March 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2321127
3 June 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2087428
18 February 2003
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1745998
25 February 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1489072
8 February 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444461
14 March 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421816
20 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798325
25 February 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426183
18 February 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400721
18 February 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442523
25 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085237
4 March 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884521
21 December 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360387
21 December 1995
Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427153
5 January 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1161297
4 February 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257344
9 October 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245381
11 June 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308184
4 March 1991
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 921602
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 3 June 2004
Resolved
Replace all fuel tank vent flame screens.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2004
Resolution: Shop mechanic replaced flame screen with stock from warehouse prior to completion of inspection.
Lifesaving › Buoyant Apparatus
Issued 3 June 2004
Resolved
Replace weathered life float
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2004
Resolution: Replaced life float with stock from warehouse during inspection.
Lifesaving › Rescue Boat › Markings
Issued 3 June 2004
Resolved
Replace all retro reflective tape.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2004
Resolution: Retro reflective tape prior to completion of inspection with stck from warehouse.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 June 2004
Resolved
Replace worn and missing exhaust insulation.
Due 3 July 2004
Resolved 26 July 2004
Construction/Loadline › Hull › Weld
Issued 18 February 2003
Resolved
Gouge & reweld misc cracked welds in hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2003
Resolution: Welds repaired.
Lifesaving
Issued 25 February 1999
Resolved
DEMONSTRATE COMPLIANCE WITH THE 8TH COAST GUARD DISTRICT POLICY "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" DATED 12 NOV 98 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Documentation
Issued 21 December 1995
Resolved
PROVIDE ON BOARD A USCG APPROVED OPERATING MANUAL; PENDING APPROVAL, VESSELMAY OPERATE WITH EXISTING OPERATING MANUAL.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Documentation
Issued 21 December 1995
Resolved
PROVIDE ON BOARD A VALID STABILITY LETTER.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Navigation
Issued 4 March 1991
Resolved
CALIBRATE MAGNETIC COMPASS ANS SUBMIT DEVIATION TABLE TO [name withheld].
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Documentation
Issued 4 March 1991
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER WASHINGTON, D.C. FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Documentation
Issued 4 March 1991
Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.: INBOARD AND OUTBOARD PROFILES, LEG_x001C_STRUCTURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Engineering
Issued 4 March 1991
Resolved
SUBMIT DOCUMENTATION THAT VERIFIES SHIPS SERVICE AIR TANK MEETS ASME CODE AND 46 CFR PART 54 OR REMOVE IT FROM THE VESSEL.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Documentation
Issued 4 March 1991
Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C. FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Documentation
Issued 4 March 1991
Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM 1 TO THE COGNIZANT OCMI.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991