← All vessels
CHANG HO
CHANG HO is a 2000 freight ship. The Coast Guard has recorded 12 inspections since 2001, most recently in December 2011, along with 6 deficiencies and 1 operational control.
Records from 2001 to 2011. Most recent: inspection, 19 December 2011.
- Built
- 2000
- Last inspected
- 19 December 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9192416 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
H3OW
17412
Flag
PANAMA
—
Maury page id
psix-17412
Inspections, by type
…with no type recorded4
Years with a record
6 calendar years (2001–2011)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it80416 - Dead Weight, Metric Ton
92233 - Displacement, Metric Ton
26594 - Convention (Subpart B), Net Ton
43568 - Convention (Subpart B), Gross Ton
92233 - Displacement, Metric Ton
26594 - Convention (Subpart B), Net Ton
43568 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
19 December 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4196881
29 January 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3402264
24 January 2009
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3399529
26 December 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3384968
24 November 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3368843
17 December 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3116727
13 December 2007
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3115486
7 June 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1627969
6 February 2002
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1484555
20 December 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1477592
20 December 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1484472
24 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 290417
Deficiency record · 6
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 26 December 2008
Resolved
0710: Two pieces of lagging are oil soaked next to the No. 2 purifier F.O. feed pump suction gauge and one piece of lagging is oil soaked next to the No. 1 and No. 2 F.O. feed pumps. The No. 2 purifier F.O. feed pump is leaking fuel oil into the containment area and both strainers are dripping fuel oil. The amount of fuel oil around this pump in the purifier room presents a fire hazard.
Construction/Loadline › Structures › Ventilators
Issued 26 December 2008
Resolved
9900: The ventilation duct in the Bosun storage is wasted providing a one foot by six inch hole in the duct. The cause of this hole is due to corrosion and rust. SOLAS 2001 Cons. Ch 1 Reg 11
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 17 December 2007
Resolved
GROUNDING WIRE ON STARBOARD LIFEBOAT IS DISCONNECTED FROM DECK
Lifesaving › Lifeboat Equipment › Hand Flare
Issued 17 December 2007
Resolved
ALL ROCKET PARACHUTE, HAND FLARES AND BUOYANT SMOKE SIGNALS ARE EXPIRED ON BRIDGE AND LIFEBOATS.
Fire Fighting › Fire Main › Condition
Issued 17 December 2007
Resolved
FIRE/BALLAST/GENERAL SERVICE PUMPS (TWO) HAVE SIGNIFICANT WATER LEAKS. AT THIS TIME PRESSURE IS NOT AFFECTED.
Electrical › Electric Generation Source (service) › Neutral Ground
Issued 17 December 2007
Resolved
NONE OF THE MAIN SWITCHBOARDS IN THE ENGINE ROOM HAVE NON-CONDUCTIVE MATS OR GRATES PROVIDED AT THE FRONT/REAR, AS NECESSARY.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.