← All vessels
FULL STEAM
FULL STEAM is a 1977 towing vessel. The Coast Guard has recorded 8 inspections since 2001, most recently in September 2025, along with 4 deficiencies.
Records from 2001 to 2025. Most recent: inspection, 26 September 2025.
- Built
- 1977
- Last inspected
- 26 September 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
610020
WDL4515
174152
Flag
UNITED STATES
368132180
Maury page id
psix-174152
Inspections, by type
…with no type recorded1
Years with a record
7 calendar years (2001–2025)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)44.7 ft × 18.0 ft × 5.7 ft
Registered tonnagegross 43 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDRAVO STEELSHIP CORPORATION · PINE BLUFF, AR, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW IBERIA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 January 2026 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL4515MMSI 368132180 · active · compulsorily equipped · granted 14 February 2020, expires 14 February 2030
WDF3462MMSI 367440160 · expired · compulsorily equipped · granted 19 February 2010, cancelled 25 April 2020
WCP3726MMSI not assigned · expired · voluntarily equipped · granted 13 December 1994, cancelled 12 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 8
26 September 2025
TPO Audit
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8247086
9 July 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8180198
24 June 2020
Initial Certification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6983770
1 February 2012
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4237826
15 December 2011
Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4209120
30 October 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2810377
31 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2005570
5 December 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 296228
Deficiency record · 4
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2020
Resolved
Fuel Shut Off Requirements. To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shut of valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime move. The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. The valve must be operable from a safe place outside of the space where the valve is installed. The remote shut off valve was not located at the tank, rather installed at a secondary valve approximately two feet away from the valve installed at the tank. Vessel shall install a remote valve to the valve directly outside of the tank for all fuel lines supplying fuel to the propulsion engines and generator prime mover. Note that piping was not marked or labeled to identify if additional piping requires remote shut offs. (see next deficiency). 46 CFR 143.260(b)-(d)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2020
Resolved
Piping for flammable or combustible liquid, seawater cooling, or fire fighting systems must be fitted with isolation valves that are clearly marked by labeling or
color coding that enable the crew to identify its function. No fuel line valves were labeled or color coded. Vessel shall properly mark all fuel line isolation valves and identify any additional valves which may need to be marked.
46 CFR 143.250(c)
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 24 June 2020
Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable type II or type III device. The vessel's type II MSD overboard discharge piping was leaking/spraying sewage excessively into the engine room when in operation causing a safety hazard. Vessel shall repair all leaks to MSD piping system. 33 CFR 159.7(a)
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 June 2020
Resolved
An exposed hazard such as gears and rotating machinery must be protected by a cover, guard, or rail. The starboard generator was missing its guard on the side ventilation opening, exposing the rotating gear and causing a potential safety hazard to crew members on board. Vessel shall install cover or guard over opening. 46 CFR 144.820
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.