MAURY USCG vessel records
← All vessels

FULL STEAM

Built
1977
Last inspected
26 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 26 September 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2001–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL4515
174152
Flag
UNITED STATES
Maury page id
psix-174152

Documentation record

Registered dimensions (L × B × D)44.7 ft × 18.0 ft × 5.7 ft
Registered tonnagegross 43 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDRAVO STEELSHIP CORPORATION · PINE BLUFF, AR, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW IBERIA, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 30 January 2026 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 8 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

26 September 2025 TPO Audit
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8247086
9 July 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8180198
24 June 2020 Initial Certification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6983770
1 February 2012 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4237826
15 December 2011 Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4209120
30 October 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2810377
31 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2005570
5 December 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 296228

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2020 Resolved
Fuel Shut Off Requirements. To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shut of valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime move. The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. The valve must be operable from a safe place outside of the space where the valve is installed. The remote shut off valve was not located at the tank, rather installed at a secondary valve approximately two feet away from the valve installed at the tank. Vessel shall install a remote valve to the valve directly outside of the tank for all fuel lines supplying fuel to the propulsion engines and generator prime mover. Note that piping was not marked or labeled to identify if additional piping requires remote shut offs. (see next deficiency). 46 CFR 143.260(b)-(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 1 July 2020
Resolution: TPO Accepted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2020 Resolved
Piping for flammable or combustible liquid, seawater cooling, or fire fighting systems must be fitted with isolation valves that are clearly marked by labeling or color coding that enable the crew to identify its function. No fuel line valves were labeled or color coded. Vessel shall properly mark all fuel line isolation valves and identify any additional valves which may need to be marked. 46 CFR 143.250(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 1 July 2020
Resolution: TPO Accepted.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 24 June 2020 Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable type II or type III device. The vessel's type II MSD overboard discharge piping was leaking/spraying sewage excessively into the engine room when in operation causing a safety hazard. Vessel shall repair all leaks to MSD piping system. 33 CFR 159.7(a)
Action required: 10 - Deficiency Rectified
Due 24 July 2020
Resolved 1 July 2020
Resolution: TPO Accepted.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 June 2020 Resolved
An exposed hazard such as gears and rotating machinery must be protected by a cover, guard, or rail. The starboard generator was missing its guard on the side ventilation opening, exposing the rotating gear and causing a potential safety hazard to crew members on board. Vessel shall install cover or guard over opening. 46 CFR 144.820
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 1 July 2020
Resolution: TPO Accepted.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.