This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it4490 - Convention (Subpart B), Gross Ton 2125 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
15 February 2023Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 7637363
26 July 2022PSC A
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 7518252
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 July 2022Resolved
Every oil fuel pipe which if damaged would allow oil to escape from storage, shall be fitted with an additional valve that can be operated outside the tunnel or similar space in the event of a fire.
Emergency Generator's fuel tank has no means to close it's fuel supply valve from outside the space.
DEF shall remain no later than ship's next dry dock.
74SOLAS(97)II-2/15.2.5
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 July 2023
Resolved 15 February 2023
Resolution: Remote valve was install outside the E-GEN Space, see document attached
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.