ODYSSEY

ODYSSEY is a 1979 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1994, most recently in March 2026, along with 160 deficiencies and 7 operational controls, 1 with no removal date recorded.

Records from 1994 to 2026. Most recent: inspection, 30 March 2026.

Built
1979
Last inspected
30 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDJ6006
174286
Flag
UNITED STATES
367793420
Maury page id
psix-174286

Inspections, by type

…with no type recorded5
Years with a record 31 calendar years (1994–2026)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.3 ft × 15.8 ft × 7.0 ft
Registered tonnagegross 43 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMF HATTERAS YACHTING · NEW BERN, NC, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN PEDRO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 20 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ6006MMSI 367793420 · active · compulsorily equipped · granted 7 June 2017, expires 7 June 2027
WDD7759MMSI 367190940 · expired · compulsorily equipped · granted 31 May 2007, cancelled 5 August 2017
WDA4775MMSI 366812970 · expired · compulsorily equipped · granted 25 May 2001, cancelled 30 July 2011
WCW9047MMSI not assigned · expired · compulsorily equipped · granted 15 October 1996, cancelled 16 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

30 March 2026 Vessel Attendance · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8315098
15 December 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8257160
18 September 2024 Administrative Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8005276
9 September 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7975830
8 September 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7998837
19 March 2024 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7847905
29 January 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7857145
8 September 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7757039
2 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7758797
22 February 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640276
13 January 2023 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7621116
9 June 2022 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7457669
20 April 2022 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7434864
24 February 2022 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7391138
31 January 2022 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7379660
3 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7301526
5 August 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7278345
9 November 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7092194
21 October 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7082020
2 October 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7102191
23 December 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6869966
22 August 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6761776
4 September 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6533940
5 January 2018 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6333418
5 June 2017 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6150390
8 August 2016 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5966677
19 January 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5786601
26 August 2015 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5205048
19 August 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4884074
5 June 2012 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4286331
27 February 2012 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4194187
6 September 2011 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4137881
17 February 2010 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3681174
19 January 2010 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3635573
14 January 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3664178
3 February 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3404279
20 January 2009 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3402903
12 January 2009 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3377193
29 April 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3195324
5 February 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3139156
2 July 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2981283
6 June 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2933067
4 June 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2951420
27 June 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2737398
10 April 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2594019
15 February 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2585968
20 January 2006 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2570068
10 March 2005 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2308063
16 February 2005 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2290052
24 February 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2022936
25 November 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1954347
13 February 2003 Annual Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1744273
26 February 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1488584
19 November 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1379638
27 February 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395642
18 February 2000 Deficiency Check · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1410247
2 November 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1411994
24 August 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1446812
19 February 1999 COI Inspection · Drydock Extension
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1393097
21 August 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406177
12 May 1997 Initial Certification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1451186
13 February 1996 Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 884491
28 February 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1442220
24 June 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377222

Deficiency record · 160

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 December 2025 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. MI observed inoperable ring buoy waterlight due to dead battery. Restrict to daytime operation until waterlight is operational.
Action required: 705 - Other - as specified
Due 29 December 2025
Resolved 28 January 2026
Resolution: New batteries installed in waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 December 2025 Resolved
A life float must be approved under approval series 160.027 or other standard specified by the Commandant. Each life float must meet the requirements in subpart 160.010 of this chapter. Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. The material must be in strips at least 50 mm (2 in.) wide extending from top to bottom over the side or end and continuing over the top and bottom surfaces of the apparatus. MI observed deteriorated retroreflective material on the life floats. Replace retroreflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2025
Resolved 28 January 2026
Resolution: Retro reflective tape on life floats renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 September 2024 Resolved
A vessel must be operated in accordance with applicable laws and regulations in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons to be transported. Deficiencies 02-05, 7-17, 19-21, 23, 24, 26, and 27 provide objective evidence that the vessel is substandard and not proactively managing technical and operational requirements. Vessel must complete a satisfactory COI re-inspection prior to any movement.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Vessel re-inspected and found to be in satisfactory condition.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 September 2024 Resolved
At each inspection the firefighting equipment of all vessels shall be inspected. The marine inspector shall conduct the following examinations: All hand portable fire extinguishers shall be examined for excessive corrosion and general condition. Vessel’s portable fire extinguisher for the upper passenger accommodation space was discharged with the indicator in the red and required servicing. 46 CFR 176.25-25(a)(OLD CFRs)
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Extinguisher replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 September 2024 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The last annual servicing of fixed and portable extinguishers exceeds one year.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Valid fire equipment service certificate onboard.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 September 2024 Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. The starboard E/R vent closures failed to close due to excessive corrosion. 46 CFR 181.20-35(a) (OLD CFRs)
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Proper operation of vent closures witnessed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 September 2024 Resolved
A vessel not required to have a power-driven fire pump by 181.300 must have at least three 2.5 gallon bucketswith an attached lanyard, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel only had two fire buckets onboard.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: New fire buckets provided and onboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 September 2024 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. An excessive accumulation of clutter and debris created a fire hazard and obstructed emergency exits in the forward and aft accommodation space.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Clutter removed and markings on hatches renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2024 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. The waterlight is inoperable. Vessel is restricted to daytime operations only until rectified by attending marine inspector.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Proper operation of waterlight witnessed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2024 Resolved
A vessel must have one or more ring life buoys. The ring life buoy is unserviceable and must be replaced.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: New ring buoy placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 September 2024 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—(1) Six hand red flare distress signals approved in accordance with § 160.021 … and (2) Six hand orange smoke distress signals approved in accordance with § 160.037. All hand red flares and hand orange smoke distress signals on the vessel are expired.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: New flares placed into service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2024 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. The lazarette submersible bilge pump wiring is disconnected rendering the pump inoperable. The port engine room submersible bilge pump is not mounted. 46 CFR 182.25-1(a)(OLD CFRs)
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Proper operation of all bigle pumps witnessed.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 9 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and the vessel from electrical hazards, including fire and electrical shock. The vessel had numerous wiring issues which posed a major hazard to passengers and crew. The hazards identified include: deteriorated battery cable connection in port E/R, dead end wiring on starboard E/R battery installation, dead end wiring at operating station adjacent to VHF radio, and various exposed and dead end wiring throughout vessel.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Dead end wiring removed and battery cable replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 September 2024 Resolved
The intent of this part is to ensure that the scantlings, material, fastenings, workmanship, and arrangement of each vessel are as such to provide for safe operation in accordance with the terms of its COI. Primary consideration shall be given to the provisions of a seaworthy hull. Vessel has excessive water intrusion coming from both propeller shafts, causing the automatic bilge pumps to frequently operate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2024
Resolution: Shaft seals tighted and excessive water ingress corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2024 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high-water level in each of the following normally unmanned spaces: A machinery space bilge, shaft alley bilge, or other spaces subject to flooding from sea water piping. Vessel’s bilge alarm in the forward void does not provide a visual indication at the operating station and vessel does not have bilge alarms for the engine room or lazarette.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2024
Resolution: Proper operation of all bilge alarms witnessed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 September 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines. The shutoff valve at the tank shall be operable from outside the tank compartment. The emergency fuel shutoff valve is inoperable as designed and required vice grips to operate. 46 CFR 182.20-40(b)(3)(OLD CFRs)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2024
Resolution: Proper operation of emergency fuel shutoff valves witnessed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 September 2024 Resolved
The equipment required for life floats must meet the following specifications: Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs, and buoyant. Vessel’s paddles were not secured to their respective life floats and were not labeled with the vessel’s name.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2024
Resolution: Paddles tied in plave and properly marked.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 September 2024 Resolved
Firefighting, abandon ship, and man overboard drills and training shall be logged or otherwise documented for review by the coast guard upon request. The drill entry shall include the following information: date of the drill and training and a general description of the drill scenario and training topics. Vessel did not have a logbook and was not recording any required drills and training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Vessel has log book with appropriate log entries.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 September 2024 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of the portable lights was inoperable with dead batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Portable lights replaced.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 September 2024 Resolved
Complete and simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and the CO2 cylinder storage room. The instructions for local CO2 control were missing. 46 CFR 181.20-15(d)(OLD CFRs)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 3 October 2024
Resolution: Instructions posted.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 September 2024 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: “Emergency Exit, Keep Clear”. The emergency escape markings were worn and illegible. 46 CFR 177.30-15(a) (OLD CFRs)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Escape hatches properly marked.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 September 2024 Resolved
An individual may not be engaged or employed, including self-employment, on a vessel in a position as master, operator, or person in charge for which a credential is required by law or regulation unless all crewmembers covered by this section are subject to the random testing requirements of this section. The master employed onboard the vessel during the inspection was not enrolled in the vessel’s DAPI program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Current DAPI enrollment for Master and crew witnessed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 September 2024 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of sub chapter A of this chapter shall comply with the requirements of § 4.06 in sub chapter A of this chapter. Vessel's required alcohol testing swabs were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Alcohol test strips replaced with valid ones.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 September 2024 Resolved
Rails shall consist of evenly spaced courses and the spacing between courses shall be not greater than 12 inches. On passenger decks of vessels’ engaged in excursion type operation, rails shall be at least 42 inches high. The space below the rail shall be fitted with bulwarks, chain link fencing, or the equivalent. The space between rail courses were approximately 20 inches, exceeding the rail course requirements for an excursion vessel. 46 CFR 177.35-1(b)&(c)(OLD CFRs)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 16 November 2024
Resolution: Rail courses installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 September 2024 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and conduct the following inspections of the hull structure: Inspect all railings and bulwarks and their attachment to the hull structure. The starboard railing, adjacent to the operating station, is unsecured due to the use of unsuitable wood screws for the hinge pin connection. 46 CFR 176.25-5(a)(4)(OLD CFRs)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Proper pins installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 September 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Nav pubs updated.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 September 2024 Resolved
Life floats must not be stowed in tiers more than 4 feet high. When stowed in tiers, the separate units must be kept apart by spacers. Spacers between lifefloats were missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Spacers between floats installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2024 Resolved
Lighting fixtures shall be contrasted in accordance with the requirements of UL Inc. Standard for Marine Type Electric Lighting Fixtures. An overhead light in the E/ R was missing its globe. 46 CFR 183.10-20(l)(OLD CFRs)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 3 October 2024
Resolution: New light fixture installed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 9 September 2024 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The waterlight lanyard is deteriorated and frayed. Vessel is restricted to daytime operations only untilrectified by attending marine inspector.
Action required: 705 - Other - as specified
Resolved 18 September 2024
Resolution: Laynard renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 9 September 2024 Resolved
If a vessel operates on exposed or partially protected waters, an opening port light is not permitted below the weather deck unless it has an inside, hinged dead cover. 46 CFR 171.119(a)(OLD CFRs)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 29 December 2024
Resolution: Lexan windows installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 September 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel lost operation of the electronic throttles resulting in the inability to control propulsion.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 September 2024
Resolution: Control wiring replaced. Proper operation while underway witnessed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 September 2023 Resolved
Vessel must be equipped with LF of an aggregate capacity that will accommodate 100% of total number of persons on a limited coastwise route in cold water. Vessel has (1) 22 person LF and will be restricted to 22 total persons during cold water months on a limited coastwise route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 January 2024
Resolution: MI verified additional LF stored properly on vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 8 September 2023 Resolved
No marine employer shall hire any person as crewmember without a passed chemical test. Licensed mariner needs pre-employment screening.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2023
Resolved 30 November 2023
Resolution: Received evidence of Marine Employer passing pre-employment chemical drug testing
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 8 September 2023 Resolved
Marine employers must ensure crewmembers meet chemical testing regulations. Licensed mariner was not in consortium.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2023
Resolved 6 November 2023
Resolution: Master enrolled in consortium
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 September 2023 Resolved
Vessel neds FCC Station license for maritime service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2023
Resolved 6 November 2023
Resolution: Received copy of FCC Station License
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 September 2023 Resolved
Vessel needs a detailed inspection by FCC and obtain a Communications Act Radiotelephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2023
Resolved 27 December 2023
Resolution: Received signed FCC Comms Act certificate
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 June 2022 Resolved
Must have on board FCC type accepted CAT 1 406 MHz EPIRB. MI found no EPIRB registration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2022
Resolved 24 June 2022
Resolution: Operator emailed EPIRB registration. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2022 Resolved
Marine Employer shall comply with requirements of 4.06 in subchapter A. MI found no DAPI Consortium enrollment letter.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2022
Resolved 10 June 2022
Resolution: DAPI consortium provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 June 2022 Resolved
Vessel must be provided with satisfactory arrangement for draining any water tight compartment. MI found bilge system inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2022
Resolved 10 June 2022
Resolution: All bilge pumps operating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 June 2022 Resolved
Double hose clamping is required. MI found multiple area without double clamps on bilge syste.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2022
Resolved 10 June 2022
Resolution: Clamps in place.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 9 June 2022 Resolved
Vessel must submit plans for installation of monitoring devices to ensure the wakefulness of watchmen. No plans submitted for watch alert system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 2 August 2023
Resolution: Vessel no long need watch alert system due to COI amendment removing overnight accommodations.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 February 2022 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. If webbing is used to secure life lines and pendants, it must be at least 50 mm (2 in.) wide and must have a breaking strength of at least 3.4 kN (750 lb.) for apparatus of under 25 persons capacity, and 6.7 kN (1,500 lb.) for apparatus of 25 persons capacity and higher. 22 person life float was found with two securing points for the life line severed. Repair or replace life float. Until a serviceable life float is provided, vessel is restricted to 1 NM from shore while carrying passengers or cargo.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 20 April 2022
Resolution: Vessel provided serviceable 22 person life float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and all other hazardous situations must be corrected. At required hull exam vessel was identified that both port and stbd propellers were not in serviceable condition. Both propellers had severe cracking and damage/broken trailing edges. Vessel to make shaft/props, and all associated components available for inspection during next hull exam and correct as required.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2022
Resolution: Vessel completed replacement of both propellers and both intermediate bearings.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2022 Resolved
The owner or managing operator shall make a vessel available for dry dock exam and internal structure exam, as required. Vessel did not complete a satisfactory hull exam. Vessel is required to make vessel available for hull exam and credit dry dock. All items to be completed to the satisfaction of the attending marine inspector and prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2022
Resolution: Vessel completed dry dock exam.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 September 2021 Resolved
Footholds, handholds, ladders, and similar means provided to aid escape, must be suitable for use in emergency conditions, of rigid construction, and permanently fixed in position, unless they can be folded, yet brought into immediate service in an emergency. No ladder installed for aft accommodation space egress hatch.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 6 October 2021
Resolution: Inspected installed escape ladder.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 September 2021 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. BMDE’s and SSDG does not secure up CO2 Activation
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2021
Resolved 6 October 2021
Resolution: Witnessed proper operation of CO2 Engine Shutdowns.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 September 2021 Resolved
Each survival craft must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. 01 Life Float was found deteriorated and outer coating cracked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2021
Resolved 6 October 2021
Resolution: Vessel replaced life float. Al appeared satisfactory.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 November 2020 Resolved
Machinery and fuel tank spaces shall be seperated from accommodation spaces by vapor tight bulkheads. MI discovered bulkhead penetrations in generator room to not be vapor tight. Vessel needs to seal penetrations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 26 November 2020
Resolution: Penetrations sealed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 November 2020 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The vessel failed to produce 03 of 04 bilge high level alarms at the operating station.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 13 November 2020
Resolution: Vessel recitifed issue prior to MI leaving. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Due to the electrical problems onboard the vessel: the vessel has failed it’s annual inspection. Vessel must complete an annual inspection prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 November 2020
Resolution: Vessel received satisfactory annual inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 November 2020 Resolved
Adequate emergency lighting shall be fitted along the line of escape. Vessel not equipped with emergency lighting in forward accommodation space. Vessel to provide space with adequate emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 26 November 2020
Resolution: Vessel added and satisfactorily tested E-Lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 9 November 2020 Resolved
Each survival craft must be secired to the vessel by a painter with a float free link. MI discovered vessel did not have a painter or float free link.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 November 2020
Resolution: Vessel obtained and installed a painter and weak link to the life floats prior to the MI departing. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2020 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel has not completed a satisfactory annual inspection. Vessel cannot carry passengers until a satisfactory annual inspection is completed.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2020
Resolved 9 November 2020
Resolution: Cleared 701(c). Converted to 60(c) see activity 7092194
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 December 2019 Resolved
At each initial and subsequent inspection the owner or managing operator shall be prepared to test the steering system of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Port and starboard rudder packing leaking excessive water into the bilge. Provide means to repack rudders to stop the ingress of water. Rectify deficiency prior to movement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2020
Resolution: Rudders were removed and repacked. Leaking issue resovled.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 December 2019 Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. Port and starboard main shaft cutlass bearings worn passed 50%. Port shaft cutlass bearing has slipped out of the strut and is close to contacting the propeller. Pull port and starboard shafts for inspection and replace port and starboard main strut cutlass bearings prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2020
Resolution: Replaced port and STDB main cutlass bearings.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 December 2019 Resolved
A vessel is inspected for compliance with the sandards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the OCMI as good marine practice. Battery Charger in generator space has its power cord running up the foldable stairs to the next deck and is plugged into an outlet. The cord is being pinched and chaffed by the stairs. Provide a plan to hardwire the battery charger into to the vessels circuit panel with proper overcurrent protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 January 2020
Resolution: Battery charger is hard wired into vessel braker panel with 15 amp overcurent protection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 August 2019 Resolved
FOR FIXED GAS FIRE EXTINGUISHING SYSTEM: DEVICE MUST BE PROVIDED TO SHUT DOWN POWER VENTILATION SERVICING PROTECTED SPACE. SPRING ON PORT ENGINE ROOM VENTILATION CLOSURE WASTED. REPLACE AND PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2019
Resolved 29 August 2019
Resolution: MI recieved satisfactory evidence of spring replacement / operation.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 28 August 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 August 2019
Resolution: Rectified on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 28 August 2019 Resolved
LIFE FLOAT MUST HAVE WATERLIGHT. WATER LIGHT NOT FUNCTIONAL. PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 18 September 2019
Resolution: [name withheld] cleared def.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 August 2019 Resolved
ELECTRICAL EQUIPMENT MUST BE INSTALLED AND MAINTAINED TO PROTECT PASSENGERS, CREW, AND THE VESSEL AND ALSO PREVENT THE IGNITION OF FLAMMABLE VAPORS. EXPOSED ELECTRICAL WIRINGS, JUNCTIONS, AND IMPROPERLY SECURED WIRES IN ENGINE AND GENERATOR ROOMS. RECTIFY DEFICIENCIES TO SATISFACTION OF ATTENDING COAST GUARD INSPECTOR.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 18 September 2019
Resolution: [name withheld] cleared def.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 28 August 2019 Resolved
MASTER SHALL ENSURE VESSEL COMPLIES WITH ALL APPLICABLE STABILITY REQUIREMENTS. VESSEL HAD INCORRECT LABELING AT LADDERWELL FOR MAX PASSENGER COUNT ON UPPER DECK. PROVE PROPER LABELLING.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 18 September 2019
Resolution: [name withheld] cleared def.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 22 January 2018 Resolved
Valve did not close properly upon testing.
Action required: 10 - Deficiency Rectified
Due 22 January 2018
Resolved 22 January 2018
Resolution: Rectified within 30 minutes onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 June 2017 Resolved
Provide a valid FCC ship radio station authorization certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2017 Resolved
Provide updated charts for navigation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See narrative
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2017 Resolved
Provide a vald first aid kit or required contents.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: see narrative
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 June 2017 Resolved
Renew retroreflective tape for 06 lifejackets on bow.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See narrative
Lifesaving › Lifebuoys › Serviceable
Issued 5 June 2017 Resolved
Renew retroreflective tape for stern ring buoy.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See narrative
Operations/Management › Equipment Service/Testing › EPIRB
Issued 31 August 2016 Resolved
Provide new hydrostatic release unit for EPIRB, Restricted to no more than 03 miles from mainland shore. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 2 September 2016
Resolution: See Narrative
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 August 2016 Resolved
Insert horizontal rail courses in bow railing so no verticle space exceeds 12 inches. To also include PORT/STBD embarkation zones. Passengers restricted from accessing bow. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 31 August 2016 Resolved
Provide new retroreflective tape for all lifejackets as identified. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Navigation › Piloting/Steering › Marine Charts
Issued 31 August 2016 Resolved
Provide up to date charts for Catalina Island and the LA/LB harbors. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 31 August 2016 Resolved
Provide proper mounting bracket for portable fire extinguisher on top deck, B:I. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 31 August 2016 Resolved
Provide smoke detector battery for portside passenger stateroom. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Engineering › Fuel Oil Service System › Filter
Issued 31 August 2016 Resolved
Provide two drip pans for port MDE fuel strainers. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 31 August 2016 Resolved
Provide battery for lifefloat waterlight. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Documentation › Logs/Records › MIS Form
Issued 31 August 2016 Resolved
Provide MIS report for drug and alcohol program. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Fire Fighting › Means of Escape › Escape Route Signs
Issued 31 August 2016 Resolved
Make the aft deck emergency escape sign permanent, non-moveable. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 19 January 2016 Resolved
Provide guage report for shaft bearings
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 22 January 2016
Resolution: Guageing report provided bearing within tollerances.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 19 January 2016 Resolved
Repair or replace port MDE sea valve
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 22 January 2016
Resolution: Sea Valve replaced
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 19 January 2016 Resolved
Provide report for pitting on propellers
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 22 January 2016
Resolution: Report on propeller pitting is within tollerances
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 19 January 2016 Resolved
Paint vessel name on port and stbd hull/bow
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 22 January 2016
Resolution: Name painted on vessels bow
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 August 2015 Resolved
Provide 01 waterlight attached with an 18' line to lifefloat. 46CFR180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2015
Resolved 29 September 2015
Resolution: Vessel provide a new waterlight for the life float missing one.
Lifesaving › Lifefloat › Retroreflective Material
Issued 26 August 2015 Resolved
Replace retroreflective tape on both life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2015
Resolved 29 September 2015
Resolution: Vessel renewed retroreflective tape on both life floats with approved SOLAS type.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 August 2015 Resolved
Make lighting in port engine room explosion-proof. 46 CFR 183.530
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2015
Resolved 29 September 2015
Resolution: Vessel provided explosion-proof cover over lights in port engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 August 2015 Resolved
Remove or cap dead end wiring identified in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2015
Resolved 29 September 2015
Resolution: Vessel capped off all exposed dead end wiring.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 26 August 2015 Resolved
Mark port/stbd bow with vessel's name. 46CFR185.602(a), 46CFR67.123.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 6 September 2018
Documentation › Markings/Placards › Capacity Marking
Issued 26 August 2015 Resolved
Post upper deck max. capactiy of passengers. 46CFR185.602(e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2015
Resolved 29 September 2015
Resolution: Vessel provided upper deck capacity placard over ladder.
Lifesaving › Lifefloat › Painter
Issued 5 June 2012 Resolved
Replace sea painter line for Lifefloats. New sea painter line must be 100Feet in length, dark in color if synthetic and attached to proper sized weak link.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 15 June 2012
Resolution: Lifefloat sea painter was replaced.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 June 2012 Resolved
Remove excessive oil from both Port & Stbd engine room bilges
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 15 June 2012
Resolution: Vessel removed excessive oily water from bilge.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 5 June 2012 Resolved
Label aft emergency escape hatch "Emergency Exit-Keep Clear" on both sides.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 15 June 2012
Resolution: Aft emergency escape hatch was marked on exit side on main deck.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 5 June 2012 Resolved
Serviced B-I Extinguisher was not located at the operating station.
Action required: 705 - Other - as specified
Due 5 June 2012
Resolved 5 June 2012
Resolution: Serviced B-I Extinguisher was placed in marked location at the vessel''s operating station
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 June 2012 Resolved
Stern light is inoperative.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 5 June 2012
Resolution: This was corrected in the spot by vessel''s crew.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 6 September 2011 Resolved
Provide radio safety certificate.
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 5 October 2011
Resolution: Vessel provided radio safety cert.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 September 2011 Resolved
Provide emergency lighting for below-deck lounge spaces (berthing).
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 5 October 2011
Resolution: Emergency lighting and exit signs installed in berthing area.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 September 2011 Resolved
Repair or replace VHF-FM marine radio at primary operating station.
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 5 October 2011
Resolution: Vessel installed new VHF-FM radio at primary operating station.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 September 2011 Resolved
Remove excessive oil in STBD engine room bilge, specifically outboard of longitudinal.
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 5 October 2011
Resolution: Vessel cleaned excessive oil from engine room.
Engineering › Lubricating Oil Service System › Tank
Issued 6 September 2011 Resolved
Repair fluid leak from stabilizer reservoir or prevent from dripping on exhaust.
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 5 October 2011
Resolution: drip pan installed around stabilizer.
Engineering › Bilge Water Management System › Piping
Issued 6 September 2011 Resolved
Provide positive shutoff valve at through hull fittings for electric bilge pump.
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 5 October 2011
Resolution: Positive shut-off valve installed at through hull fitting.
Fire Fighting › Fire Bucket › Quantity
Issued 19 January 2010 Resolved
Obtain fire bucket. Requirement of three needed onboard. 2.5 gallons. 46 CFR 181.610.
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 17 February 2010
Resolution: Fire bucket obtained.
Engineering › Fuel Oil Service System › Filter
Issued 19 January 2010 Resolved
Fuel filters for port and starboard engines need flame screen IAW 46 CFR 182.455 (b)(6).
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 17 February 2010
Resolution: Flame screens provided.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 19 January 2010 Resolved
Provide proof of proper operation of port and starboard ventilation closures IAW 46 CFR 182.15-45.
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 17 February 2010
Resolution: Proof of proper operation of ventilation closures provided.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 12 January 2009 Resolved
Current alcohol test kits expired. New ordered, not yet onboard. Provide alcohol detection kits onboard for all members IAW 46CFR16.240.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 21 January 2009
Resolution: Owner supplied evidence of receipt of test kits for crew.
Documentation › Certificates/Documents › FCC SSL
Issued 12 January 2009 Resolved
Provide radio operator's permit. Vessel is restricted to within 1000 ft from shore until resolved.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 29 January 2009
Resolution: Owner provided evidence of crew member successfully passing Marine Radio Operator Course.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 January 2009 Resolved
Repair anchor light IAW NAVRULES
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 3 February 2009
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 12 January 2009 Resolved
Secure microwave in ship's galley to prevent movement underway IAW 46CFR177.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 3 February 2009
Communications › Radio Communications › EPIRB
Issued 12 January 2009 Resolved
Provide float free arrangement of vessel's EPIRB IAW 46CFR180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 12 January 2009
Resolution: Temporary float free arrangement accomplished to the satisfaction of the LMI. Maintenance will be conducted on installed float free hydrostatic release.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 6 June 2007 Resolved
Remove old generator cable no longer being used IWO generator space.
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 2 July 2007
Resolution: Secured generator cable.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 June 2007 Resolved
Provide documentation of man overboard drills and training as required by 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 2 July 2007
Resolution: Documentation provided and maintained for man overboard drills and training.
Operations/Management › Drills/Instruction › Fire
Issued 6 June 2007 Resolved
Provide documentation of firefighting drills and training as required by 46 CFR 185.524.
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 2 July 2007
Resolution: Documentation provided and maintained for firefighting drills and training.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 6 June 2007 Resolved
Provide documentation of monthly EPIRB tests as required by 46 CFR 185.728.
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 2 July 2007
Resolution: Documentation provided for monthly EPIRB test.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 6 June 2007 Resolved
Provide documentation of 1 hour supervisor EAP training.
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 7 June 2007
Resolution: Received fax documentation verifying completion of training.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 15 May 2006 Resolved
Obtain valid Radio Safety Certificate on board vessel.
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 27 June 2006
Resolution: Provided copy of vailid Radio Safety Certificate via fax to our office.
Engineering › Fuel Oil Service System › Filter
Issued 15 May 2006 Resolved
Provide drip bowls for racor filters; one on each filter; on starboard and port engine room filters.
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 27 June 2006
Resolution: Provided pictures of racor filter drip bowls installed on racor filter.
Operations/Management › Drills/Instruction › Fire
Issued 15 May 2006 Resolved
Conduct and log MOB and fire drills quarterly and IAW 185.420. Drills were not being logged. On initial attempt failed drills (MOB and Fire).
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 27 June 2006
Resolution: Drills being logged. Drills set up for 1st week of each third month.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 January 2006 Resolved
Vessel may not operate from 0000, 22 JAN 06 with passengers for hire until dry-dock inspection satisfactorily completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 February 2006
Resolved 15 February 2006
Resolution: Conducted satisfactory hull examination of vessel.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 20 January 2006 Resolved
Replace expired battery on EPIRB, route restricted to 3NM.
Action required: 705 - Other - as specified
Due 19 February 2006
Resolved 15 February 2006
Resolution: Vessel''s master had receipt from Avalon attesting to the purchase of a new battery for the EPIRB.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 January 2006 Resolved
Conduct hull exam for credit dry dock as specified on the vessels Certificate of Inspection to the satisfaction of an attending Marine Inspector. Credit for dry dock must be completed prior to carrying passengers and by 19 FEB 2006.
Action required: 705 - Other - as specified
Due 19 February 2006
Resolved 20 January 2006
Resolution: Re-issued new CG-835 allowing the vessel to operate until 0000, 22 JAN 06 upon completion of satisfactory ISE inspection.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 February 2005 Resolved
DAPI program documents are not current and proof of current enrollment are missing.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2005
Resolved 10 March 2005
Resolution: Verified current enrollment in drug program.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 February 2005 Resolved
Repair "J" cooling tube/pipe to 100% operation and remove soft patch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2005
Resolved 10 March 2005
Resolution: Verified cooling tube is 100% repaired and operational.
Engineering › Bilge Water Management System › Interface Detector
Issued 16 February 2005 Resolved
Repair aft bilge alarm float and bilge auto activation switch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2005
Resolved 10 March 2005
Resolution: Verified bilge alarm is 100% operational.
Electrical › Electric Supply System (service) › Cable
Issued 16 February 2005 Resolved
Secure all dead wires.
Condition: Improper Installation
Due 18 March 2005
Resolved 10 March 2005
Resolution: Verified all dead wires secured.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 16 February 2005 Resolved
Secure temporary block heater wire on both engines.
Condition: Improper Installation
Due 18 March 2005
Resolved 10 March 2005
Resolution: Secured temporary block heater wire on both engines.
Fire Fighting › Ventilation Systems › Fans
Issued 16 February 2005 Resolved
Reactivate starboard engine compartment ventilation fan.
Condition: Improper Installation
Due 18 March 2005
Resolved 10 March 2005
Resolution: Reactivated starboard engine compartment vent fan.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 16 February 2005 Resolved
Install sign on main controls to say "secure ventilation prior to CO2 activation," or some other appropriate warning sign.
Condition: Placed in Improper Service
Due 18 March 2005
Resolved 10 March 2005
Resolution: Installed sign at main control station.
Electrical › Electric Supply System (service) › Cable
Issued 16 February 2005 Resolved
Secure starboard wire bundle w/ metal clips.
Condition: Improper Installation
Due 18 March 2005
Resolved 10 March 2005
Resolution: Secured starboard wire bundle w/ metal clips.
Stability
Issued 4 March 2003 Resolved
Vessel appears to have modifications completed after stability test was conducted on 13FEB96. Remove all canvas coverings on upper deck. Vessel needs to complete new stability test prior to 04APR03. Also ensure railing is in compliance with 46 CFR 177.900.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2003
Resolved 25 March 2003
Construction/Loadline › Structures
Issued 13 February 2003 Resolved
Make port lights below maindeck permanently closed. Route reduced to lakes, bays & sounds. LEGACY COMPONENT DESC: Superstructure
Due 4 April 2003
Resolved 12 April 2003
Documentation
Issued 27 February 2001 Resolved
Provide an FCC Safety Certificate
Condition: Unknown
Due 20 March 2001
Resolved 25 August 2001
Lifesaving
Issued 27 February 2001 Resolved
properly stencil lifefloat according to 46cfr185.604e with 1 1/2 inch letters and numbers
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Lifesaving
Issued 27 February 2001 Resolved
provide a lifejacket donning placard according to 46 CFR 185.516
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Fire Fighting
Issued 27 February 2001 Resolved
Provide current training and EPIRB logbook according to 46 CFR 185.420
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Lifesaving
Issued 27 February 2001 Resolved
Vessel is restricted to the carriage of 47 adult passengers until 06 MARCH 2001. Must provide full complement of PFDs prior to this date.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Lifesaving
Issued 27 February 2001 Resolved
provide a watertight approved container for the distress signals IAW 46 CFR180.68e.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Lifesaving
Issued 27 February 2001 Resolved
Provide a properly operating ring life buoy waterlight.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Accommodation/Occupational Safety
Issued 27 February 2001 Resolved
Properly mark the forward bunkroom emergency exit hatch IAW 46 CFR 185.606
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Lifesaving
Issued 27 February 2001 Resolved
Make the lifefloat to have a float free arrangement IAW 46 CFR 180.130
Condition: Unknown
Due 20 March 2001
Resolved 25 August 2001
Fire Fighting
Issued 18 February 2000 Resolved
Install smoke detectors in forward, midship and aft berthing areas.
Condition: Unknown
Due 2 March 2000
Resolved 3 March 2000
Fire Fighting
Issued 18 February 2000 Resolved
Provide servicing report for fixed CO2 system.
Condition: Unknown
Due 2 March 2000
Resolved 3 March 2000
Navigation
Issued 18 February 2000 Resolved
Repair sternlight.
Condition: Unknown
Due 2 March 2000
Resolved 3 March 2000
Construction/Loadline
Issued 18 February 2000 Resolved
MAKE AIR VENT IN THE FWD HATCH WATERTIGHT.
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000
Construction/Loadline
Issued 18 February 2000 Resolved
PROVIDE MEANS TO OPEN THE HATCH LEADING FROM MAIN DECK TO FWD BERTHING AREAFROM THE OUTSIDE.
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000
Navigation
Issued 18 February 2000 Resolved
Modify aft, upper deck dodger to allow sternlight to be seen.
Condition: Unknown
Due 2 March 2000
Resolved 3 March 2000
Navigation
Issued 18 February 2000 Resolved
Repair and reinstall mast light.
Condition: Unknown
Due 2 March 2000
Resolved 3 March 2000
Navigation
Issued 18 February 2000 Resolved
Provide emergency broadcast for each radio.
Condition: Unknown
Due 2 March 2000
Resolved 3 March 2000
Construction/Loadline
Issued 18 February 2000 Resolved
Install bilge high level alarms in port and starboard engine room as well as the generator room.
Condition: Unknown
Due 2 March 2000
Resolved 3 March 2000
Documentation
Issued 18 February 2000 Resolved
Provide chemical testing program.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Engineering
Issued 2 November 1999 Resolved
Have port side propeller refinished or replaced prior to end of drydock.
Condition: Unknown
Due 15 November 1999
Resolved 16 November 1999
Fire Fighting
Issued 19 February 1999 Resolved
Provide vent closures to those spaces protected by the fixed firefighting system.
Condition: Unknown
Due 25 July 1999
Resolved 2 November 1999
Accommodation/Occupational Safety
Issued 19 February 1999 Resolved
Provide second means of escape for berthing spaces.
Condition: Unknown
Due 19 February 1999
Resolved 19 February 1999
Fire Fighting
Issued 19 February 1999 Resolved
Provide dust catchers for piping on fixed fire system
Condition: Unknown
Due 25 July 1999
Resolved 2 November 1999
Electrical
Issued 19 February 1999 Resolved
Vessel missing it's battery box.
Condition: Unknown
Due 12 March 1999
Resolved 13 April 1999
Fire Fighting
Issued 19 February 1999 Resolved
Vessel missing fire buckets, needs three.
Condition: Unknown
Due 22 February 1999
Resolved 8 March 1999
Documentation
Issued 19 February 1999 Resolved
Vessel missing it's waste management plan.
Condition: Unknown
Due 22 February 1999
Resolved 8 March 1999
Navigation
Issued 19 February 1999 Resolved
Charts missing updates.
Condition: Unknown
Due 22 February 1999
Resolved 13 April 1999
Fire Fighting
Issued 19 February 1999 Resolved
Provide proper number, type, and arrangement of portable fire extinguishers.
Condition: Unknown
Due 22 February 1999
Resolved 8 March 1999
Documentation
Issued 19 February 1999 Resolved
Stability letter needs to be posted.
Condition: Unknown
Due 12 March 1999
Resolved 21 August 1999
Construction/Loadline
Issued 12 May 1997 Resolved
CONDUCT A HULL EXAM.
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Construction/Loadline
Issued 12 May 1997 Resolved
INSTALL CHECK VALVE FOR ALL THROUGH HULL FITTINGS WITHIN 6" OF WATER LINE. INSTALL CHECK VALVE FOR ALL THROUGH HULL FITTINGS FOR BILGE SYSTEM._x001C_
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Documentation
Issued 12 May 1997 Resolved
PROVIDE VESSEL'S DOCUMENTATION._x001C_
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Fire Fighting
Issued 12 May 1997 Resolved
COMPLETE STRUCTURAL FIRE PROTECTION IN GALLEY AREA.
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.