Records from 2016 to 2026. Most recent: inspection, 30 March 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 December 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. MI observed inoperable ring buoy waterlight due to dead battery. Restrict to daytime operation until waterlight is operational.
Action required: 705 - Other - as specified
Due 29 December 2025
Resolved 28 January 2026
Resolution: New batteries installed in waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 December 2025
Resolved
A life float must be approved under approval series 160.027 or other standard specified by the Commandant. Each life float must meet the requirements in subpart 160.010 of this chapter. Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. The material must be in strips at least 50 mm (2 in.) wide extending from top to bottom over the side or end and continuing over the top and bottom surfaces of the apparatus. MI observed deteriorated retroreflective material on the life floats. Replace retroreflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2025
Resolved 28 January 2026
Resolution: Retro reflective tape on life floats renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 September 2024
Resolved
A vessel must be operated in accordance with applicable
laws and regulations in such a manner as to afford
adequate precaution against hazards that might endanger
the vessel and the persons to be transported.
Deficiencies 02-05, 7-17, 19-21, 23, 24, 26, and 27
provide objective evidence that the vessel is
substandard and not proactively managing technical and
operational requirements. Vessel must complete a
satisfactory COI re-inspection prior to any movement.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Vessel re-inspected and found to be in satisfactory condition.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 September 2024
Resolved
At each inspection the firefighting equipment of all
vessels shall be inspected. The marine inspector shall
conduct the following examinations: All hand portable
fire extinguishers shall be examined for excessive
corrosion and general condition. Vessel’s portable fire
extinguisher for the upper passenger accommodation space
was discharged with the indicator in the red and
required servicing. 46 CFR 176.25-25(a)(OLD CFRs)
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Extinguisher replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 September 2024
Resolved
The owner, managing operator, or a qualified servicing
facility as applicable must conduct the following
inspections and tests: (1) Portable and semi-portable
extinguishers must be inspected and maintained in
accordance with NFPA 10. The last annual servicing of
fixed and portable extinguishers exceeds one year.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Valid fire equipment service certificate onboard.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 September 2024
Resolved
Provisions shall be made by means of plugs, covers,
etc., to prevent the admission of air into the space
protected. The starboard E/R vent closures failed to
close due to excessive corrosion. 46 CFR 181.20-35(a)
(OLD CFRs)
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Proper operation of vent closures witnessed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 September 2024
Resolved
A vessel not required to have a power-driven fire pump
by 181.300 must have at least three 2.5 gallon
bucketswith an attached lanyard, placed so as to be
easily available during an emergency. The words “FIRE
BUCKET” must be stenciled in a contrasting color on each
bucket. Vessel only had two fire buckets onboard.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: New fire buckets provided and onboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 September 2024
Resolved
At each inspection for certification and at every
other vessel inspection the bilges and other spaces may
be examined to see that there is no excessive
accumulation of oil, trash, debris, or other matter that
might create a fire hazard, clog bilge pumping systems,
or block emergency escapes. An excessive accumulation
of clutter and debris created a fire hazard and
obstructed emergency exits in the forward and aft
accommodation space.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Clutter removed and markings on hatches renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2024
Resolved
A vessel must carry one floating waterlight, unless it
is limited to daytime operation, in which case no
floating waterlight is required. The waterlight is
inoperable. Vessel is restricted to daytime operations
only until rectified by attending marine inspector.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Proper operation of waterlight witnessed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2024
Resolved
A vessel must have one or more ring life buoys. The ring
life buoy is unserviceable and must be replaced.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: New ring buoy placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 September 2024
Resolved
A vessel on an oceans, coastwise, limited coastwise, or
Great Lakes route must carry—(1) Six hand red flare
distress signals approved in accordance with § 160.021 …
and (2) Six hand orange smoke distress signals approved
in accordance with § 160.037. All hand red flares and
hand orange smoke distress signals on the vessel are
expired.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: New flares placed into service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2024
Resolved
All vessels shall be provided with a satisfactory
arrangement for draining any watertight compartment
other than small buoyancy compartments, under all
practical conditions. The lazarette submersible bilge
pump wiring is disconnected rendering the pump
inoperable. The port engine room submersible bilge pump
is not mounted. 46 CFR 182.25-1(a)(OLD CFRs)
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Proper operation of all bigle pumps witnessed.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 9 September 2024
Resolved
Electrical equipment on a vessel must be installed and
maintained to protect passengers, crew, and the vessel
from electrical hazards, including fire and electrical
shock. The vessel had numerous wiring issues which posed
a major hazard to passengers and crew. The hazards
identified include: deteriorated battery cable
connection in port E/R, dead end wiring on starboard E/R
battery installation, dead end wiring at operating
station adjacent to VHF radio, and various exposed and
dead end wiring throughout vessel.
Action required: 30 - Ship detained
Resolved 18 September 2024
Resolution: Dead end wiring removed and battery cable replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 September 2024
Resolved
The intent of this part is to ensure that the
scantlings, material, fastenings, workmanship, and arrangement of each vessel are as such to provide for
safe operation in accordance with the terms of its COI.
Primary consideration shall be given to the provisions
of a seaworthy hull. Vessel has excessive water
intrusion coming from both propeller shafts, causing the
automatic bilge pumps to frequently operate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2024
Resolution: Shaft seals tighted and excessive water ingress corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2024
Resolved
On a vessel of at least 26 feet in length, a visual and
audible alarm must be provided at the operating station
to indicate a high-water level in each of the following
normally unmanned spaces: A machinery space bilge, shaft
alley bilge, or other spaces subject to flooding from
sea water piping. Vessel’s bilge alarm in the forward
void does not provide a visual indication at the
operating station and vessel does not have bilge alarms
for the engine room or lazarette.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2024
Resolution: Proper operation of all bilge alarms witnessed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 September 2024
Resolved
Shutoff valves, installed so as to close against the
fuel flow, shall be fitted in the fuel supply lines. The
shutoff valve at the tank shall be operable from outside
the tank compartment. The emergency fuel shutoff valve
is inoperable as designed and required vice grips to
operate. 46 CFR 182.20-40(b)(3)(OLD CFRs)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2024
Resolution: Proper operation of emergency fuel shutoff valves witnessed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 September 2024
Resolved
The equipment required for life floats must meet the
following specifications: Each paddle must be of at least 4 feet in length, lashed to the life float to
which it belongs, and buoyant. Vessel’s paddles were not
secured to their respective life floats and were not
labeled with the vessel’s name.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2024
Resolution: Paddles tied in plave and properly marked.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 September 2024
Resolved
Firefighting, abandon ship, and man overboard drills and
training shall be logged or otherwise documented for
review by the coast guard upon request. The drill entry
shall include the following information: date of the
drill and training and a general description of the
drill scenario and training topics. Vessel did not have
a logbook and was not recording any required drills and
training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Vessel has log book with appropriate log entries.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 September 2024
Resolved
Each vessel must be equipped with at least two operable
portable battery lights. One of the portable lights was
inoperable with dead batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Portable lights replaced.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 September 2024
Resolved
Complete and simple instructions for the operation of
the systems must be located in a conspicuous place at or
near all pull boxes, stop valve controls and the CO2
cylinder storage room. The instructions for local CO2
control were missing. 46 CFR 181.20-15(d)(OLD CFRs)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 3 October 2024
Resolution: Instructions posted.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 September 2024
Resolved
All escape hatches and other emergency exits shall be
marked on both sides using at least 1-inch letters:
“Emergency Exit, Keep Clear”. The emergency escape
markings were worn and illegible. 46 CFR 177.30-15(a)
(OLD CFRs)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Escape hatches properly marked.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 September 2024
Resolved
An individual may not be engaged or employed, including
self-employment, on a vessel in a position as master, operator, or person in charge for which a credential is
required by law or regulation unless all crewmembers
covered by this section are subject to the random
testing requirements of this section. The master
employed onboard the vessel during the inspection was
not enrolled in the vessel’s DAPI program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Current DAPI enrollment for Master and crew witnessed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 September 2024
Resolved
A marine employer whose vessel is involved in a casualty
or incident that is, or is likely to become, a serious
marine incident as defined in § 4.03-2 of sub chapter A
of this chapter shall comply with the requirements of §
4.06 in sub chapter A of this chapter. Vessel's required
alcohol testing swabs were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Alcohol test strips replaced with valid ones.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 September 2024
Resolved
Rails shall consist of evenly spaced courses and the
spacing between courses shall be not greater than 12
inches. On passenger decks of vessels’ engaged in
excursion type operation, rails shall be at least 42
inches high. The space below the rail shall be fitted
with bulwarks, chain link fencing, or the equivalent.
The space between rail courses were approximately 20
inches, exceeding the rail course requirements for an
excursion vessel. 46 CFR 177.35-1(b)&(c)(OLD CFRs)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 16 November 2024
Resolution: Rail courses installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 September 2024
Resolved
At each initial and subsequent inspection for
certification, the marine inspector shall view the
vessel afloat and conduct the following inspections of
the hull structure: Inspect all railings and bulwarks and their attachment to the hull structure. The
starboard railing, adjacent to the operating station, is
unsecured due to the use of unsuitable wood screws for
the hinge pin connection. 46 CFR 176.25-5(a)(4)(OLD CFRs)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Proper pins installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 September 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Nav pubs updated.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 September 2024
Resolved
Life floats must not be stowed in tiers more than 4 feet
high. When stowed in tiers, the separate units must be
kept apart by spacers. Spacers between lifefloats were
missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 18 September 2024
Resolution: Spacers between floats installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2024
Resolved
Lighting fixtures shall be contrasted in accordance with
the requirements of UL Inc. Standard for Marine Type
Electric Lighting Fixtures. An overhead light in the E/
R was missing its globe. 46 CFR 183.10-20(l)(OLD CFRs)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 3 October 2024
Resolution: New light fixture installed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 9 September 2024
Resolved
Each ring life buoy with a floating waterlight must have
a lanyard of at least 910 millimeters (3 feet) in
length, but not more than 1,830 millimeters (6 feet),
securing the waterlight around the body of the ring life buoy. The waterlight lanyard is deteriorated and frayed.
Vessel is restricted to daytime operations only
untilrectified by attending marine inspector.
Action required: 705 - Other - as specified
Resolved 18 September 2024
Resolution: Laynard renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 9 September 2024
Resolved
If a vessel operates on exposed or partially protected
waters, an opening port light is not permitted below the
weather deck unless it has an inside, hinged dead cover. 46 CFR 171.119(a)(OLD CFRs)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 29 December 2024
Resolution: Lexan windows installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 September 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel lost operation of the electronic throttles resulting in the inability to control propulsion.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 September 2024
Resolution: Control wiring replaced. Proper operation while underway witnessed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 September 2023
Resolved
Vessel must be equipped with LF of an aggregate capacity that will accommodate 100% of total number of persons on a limited coastwise route in cold water. Vessel has (1) 22 person LF and will be restricted to 22 total persons during cold water months on a limited coastwise route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 January 2024
Resolution: MI verified additional LF stored properly on vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 8 September 2023
Resolved
No marine employer shall hire any person as crewmember without a passed chemical test. Licensed mariner needs pre-employment screening.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2023
Resolved 30 November 2023
Resolution: Received evidence of Marine Employer passing pre-employment chemical drug testing
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 8 September 2023
Resolved
Marine employers must ensure crewmembers meet chemical testing regulations. Licensed mariner was not in consortium.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2023
Resolved 6 November 2023
Resolution: Master enrolled in consortium
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 September 2023
Resolved
Vessel neds FCC Station license for maritime service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2023
Resolved 6 November 2023
Resolution: Received copy of FCC Station License
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 September 2023
Resolved
Vessel needs a detailed inspection by FCC and obtain a Communications Act Radiotelephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2023
Resolved 27 December 2023
Resolution: Received signed FCC Comms Act certificate
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 June 2022
Resolved
Must have on board FCC type accepted CAT 1 406 MHz EPIRB. MI found no EPIRB registration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2022
Resolved 24 June 2022
Resolution: Operator emailed EPIRB registration. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2022
Resolved
Marine Employer shall comply with requirements of 4.06 in subchapter A. MI found no DAPI Consortium enrollment letter.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2022
Resolved 10 June 2022
Resolution: DAPI consortium provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 June 2022
Resolved
Vessel must be provided with satisfactory arrangement for draining any water tight compartment. MI found bilge system inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2022
Resolved 10 June 2022
Resolution: All bilge pumps operating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 June 2022
Resolved
Double hose clamping is required. MI found multiple area without double clamps on bilge syste.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2022
Resolved 10 June 2022
Resolution: Clamps in place.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 9 June 2022
Resolved
Vessel must submit plans for installation of monitoring devices to ensure the wakefulness of watchmen. No plans submitted for watch alert system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 2 August 2023
Resolution: Vessel no long need watch alert system due to COI amendment removing overnight accommodations.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 February 2022
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. If webbing is used to secure life lines and pendants, it must be at least 50 mm (2 in.) wide and must have a breaking strength of at least 3.4 kN (750 lb.) for apparatus of under 25 persons capacity, and 6.7 kN (1,500 lb.) for apparatus of 25 persons capacity and higher. 22 person life float was found with two securing points for the life line severed.
Repair or replace life float. Until a serviceable life float is provided, vessel is restricted to 1 NM from shore while carrying passengers or cargo.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 20 April 2022
Resolution: Vessel provided serviceable 22 person life float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and all other hazardous situations must be corrected. At required hull exam vessel was identified that both port and stbd propellers were not in serviceable condition. Both propellers had severe cracking and damage/broken trailing edges. Vessel to make shaft/props, and all associated components available for inspection during next hull exam and correct as required.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2022
Resolution: Vessel completed replacement of both propellers and both intermediate bearings.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2022
Resolved
The owner or managing operator shall make a vessel available for dry dock exam and internal structure exam, as required. Vessel did not complete a satisfactory hull exam. Vessel is required to make vessel available for hull exam and credit dry dock.
All items to be completed to the satisfaction of the attending marine inspector and prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2022
Resolution: Vessel completed dry dock exam.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 September 2021
Resolved
Footholds, handholds, ladders, and similar means provided to aid escape, must be suitable for use in emergency conditions, of rigid construction, and permanently fixed in position, unless they can be folded, yet brought into immediate service in an emergency.
No ladder installed for aft accommodation space egress hatch.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 6 October 2021
Resolution: Inspected installed escape ladder.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 September 2021
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space.
BMDE’s and SSDG does not secure up CO2 Activation
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2021
Resolved 6 October 2021
Resolution: Witnessed proper operation of CO2 Engine Shutdowns.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 September 2021
Resolved
Each survival craft must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway.
01 Life Float was found deteriorated and outer coating cracked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2021
Resolved 6 October 2021
Resolution: Vessel replaced life float. Al appeared satisfactory.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 November 2020
Resolved
Machinery and fuel tank spaces shall be seperated from accommodation spaces by vapor tight bulkheads. MI discovered bulkhead penetrations in generator room to not be vapor tight. Vessel needs to seal penetrations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 26 November 2020
Resolution: Penetrations sealed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 November 2020
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The vessel failed to produce 03 of 04 bilge high level alarms at the operating station.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 13 November 2020
Resolution: Vessel recitifed issue prior to MI leaving. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Due to the electrical problems onboard the vessel: the vessel has failed it’s annual inspection. Vessel must complete an annual inspection prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 November 2020
Resolution: Vessel received satisfactory annual inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 November 2020
Resolved
Adequate emergency lighting shall be fitted along the line of escape. Vessel not equipped with emergency lighting in forward accommodation space. Vessel to provide space with adequate emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 26 November 2020
Resolution: Vessel added and satisfactorily tested E-Lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 9 November 2020
Resolved
Each survival craft must be secired to the vessel by a painter with a float free link. MI discovered vessel did not have a painter or float free link.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 November 2020
Resolution: Vessel obtained and installed a painter and weak link to the life floats prior to the MI departing. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2020
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel has not completed a satisfactory annual inspection. Vessel cannot carry passengers until a satisfactory annual inspection is completed.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2020
Resolved 9 November 2020
Resolution: Cleared 701(c). Converted to 60(c) see activity 7092194
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 December 2019
Resolved
At each initial and subsequent inspection the owner or managing operator shall be prepared to test the steering system of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Port and starboard rudder packing leaking excessive water into the bilge. Provide means to repack rudders to stop the ingress of water. Rectify deficiency prior to movement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2020
Resolution: Rudders were removed and repacked. Leaking issue resovled.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 December 2019
Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. Port and starboard main shaft cutlass bearings worn passed 50%. Port shaft cutlass bearing has slipped out of the strut and is close to contacting the propeller. Pull port and starboard shafts for inspection and replace port and starboard main strut cutlass bearings prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2020
Resolution: Replaced port and STDB main cutlass bearings.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 December 2019
Resolved
A vessel is inspected for compliance with the sandards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the OCMI as good marine practice. Battery Charger in generator space has its power cord running up the foldable stairs to the next deck and is plugged into an outlet. The cord is being pinched and chaffed by the stairs. Provide a plan to hardwire the battery charger into to the vessels circuit panel with proper overcurrent protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 January 2020
Resolution: Battery charger is hard wired into vessel braker panel with 15 amp overcurent protection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 August 2019
Resolved
FOR FIXED GAS FIRE EXTINGUISHING SYSTEM: DEVICE MUST BE PROVIDED TO SHUT DOWN POWER VENTILATION SERVICING PROTECTED SPACE. SPRING ON PORT ENGINE ROOM VENTILATION CLOSURE WASTED. REPLACE AND PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2019
Resolved 29 August 2019
Resolution: MI recieved satisfactory evidence of spring replacement / operation.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 28 August 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 August 2019
Resolution: Rectified on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 28 August 2019
Resolved
LIFE FLOAT MUST HAVE WATERLIGHT. WATER LIGHT NOT FUNCTIONAL. PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 18 September 2019
Resolution: [name withheld] cleared def.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 August 2019
Resolved
ELECTRICAL EQUIPMENT MUST BE INSTALLED AND MAINTAINED TO PROTECT PASSENGERS, CREW, AND THE VESSEL AND ALSO PREVENT THE IGNITION OF FLAMMABLE VAPORS. EXPOSED ELECTRICAL WIRINGS, JUNCTIONS, AND IMPROPERLY SECURED WIRES IN ENGINE AND GENERATOR ROOMS. RECTIFY DEFICIENCIES TO SATISFACTION OF ATTENDING COAST GUARD INSPECTOR.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 18 September 2019
Resolution: [name withheld] cleared def.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 28 August 2019
Resolved
MASTER SHALL ENSURE VESSEL COMPLIES WITH ALL APPLICABLE STABILITY REQUIREMENTS. VESSEL HAD INCORRECT LABELING AT LADDERWELL FOR MAX PASSENGER COUNT ON UPPER DECK. PROVE PROPER LABELLING.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 18 September 2019
Resolution: [name withheld] cleared def.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 22 January 2018
Resolved
Valve did not close properly upon testing.
Action required: 10 - Deficiency Rectified
Due 22 January 2018
Resolved 22 January 2018
Resolution: Rectified within 30 minutes onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 June 2017
Resolved
Provide a valid FCC ship radio station authorization certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2017
Resolved
Provide updated charts for navigation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See narrative
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2017
Resolved
Provide a vald first aid kit or required contents.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: see narrative
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 June 2017
Resolved
Renew retroreflective tape for 06 lifejackets on bow.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See narrative
Lifesaving › Lifebuoys › Serviceable
Issued 5 June 2017
Resolved
Renew retroreflective tape for stern ring buoy.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See narrative
Operations/Management › Equipment Service/Testing › EPIRB
Issued 31 August 2016
Resolved
Provide new hydrostatic release unit for EPIRB, Restricted to no more than 03 miles from mainland shore. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 2 September 2016
Resolution: See Narrative
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 August 2016
Resolved
Insert horizontal rail courses in bow railing so no verticle space exceeds 12 inches. To also include PORT/STBD embarkation zones. Passengers restricted from accessing bow. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 31 August 2016
Resolved
Provide new retroreflective tape for all lifejackets as identified. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Navigation › Piloting/Steering › Marine Charts
Issued 31 August 2016
Resolved
Provide up to date charts for Catalina Island and the LA/LB harbors. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 31 August 2016
Resolved
Provide proper mounting bracket for portable fire extinguisher on top deck, B:I. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 31 August 2016
Resolved
Provide smoke detector battery for portside passenger stateroom. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Engineering › Fuel Oil Service System › Filter
Issued 31 August 2016
Resolved
Provide two drip pans for port MDE fuel strainers. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 31 August 2016
Resolved
Provide battery for lifefloat waterlight. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Documentation › Logs/Records › MIS Form
Issued 31 August 2016
Resolved
Provide MIS report for drug and alcohol program. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Fire Fighting › Means of Escape › Escape Route Signs
Issued 31 August 2016
Resolved
Make the aft deck emergency escape sign permanent, non-moveable. To be completed to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 8 September 2016
Resolution: See Narrative
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 19 January 2016
Resolved
Provide guage report for shaft bearings
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 22 January 2016
Resolution: Guageing report provided bearing within tollerances.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 19 January 2016
Resolved
Repair or replace port MDE sea valve
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 22 January 2016
Resolution: Sea Valve replaced
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 19 January 2016
Resolved
Provide report for pitting on propellers
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 22 January 2016
Resolution: Report on propeller pitting is within tollerances
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 19 January 2016
Resolved
Paint vessel name on port and stbd hull/bow
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 22 January 2016
Resolution: Name painted on vessels bow