Records from 2001 to 2026. Most recent: inspection, 14 January 2026.
Inspection history · 41
14 January 2026
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8296144
5 December 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8043502
7 October 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8017703
21 August 2024
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7986322
20 June 2024
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7964459
18 October 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7806992
29 June 2023
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7756878
7 November 2022
Deficiency Check · COI Inspection · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7588548
31 October 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7585402
9 June 2022
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7472545
9 December 2021
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7364755
15 June 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7345300
18 November 2020
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7092359
27 October 2020
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7074102
22 October 2020
Plan Review "T" Boat
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7114984
16 January 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6890697
18 November 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6836557
24 October 2018
Drydock Exam · Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6568977
6 November 2017
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6301395
27 October 2016
Internal Structural Exam · Administrative Inspection · Annual Inspection · DAPI Audit · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6031132
16 November 2015
Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5772294
23 October 2014
Drydock Exam · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5029438
8 November 2010
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3888227
27 October 2010
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3878954
5 September 2010
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 3842417
5 September 2010
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3842469
17 February 2010
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3681078
12 February 2009
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3416797
6 November 2008
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3358402
8 February 2008
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3143986
9 July 2007
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2989699
9 July 2007
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 2991307
19 February 2007
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2874147
22 November 2005
COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2539037
8 February 2005
Administrative Inspection · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2292332
16 November 2004
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2242644
28 May 2004
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2085902
17 November 2003
Annual Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1949516
9 December 2002
Deficiency Check · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1716170
7 November 2002
Hull Examination · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1700711
5 December 2001
Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1481286
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 December 2024
Resolved
Provide 3 additional adult life jackets. Vessel restricted to 32 passengers.
Action required: 705 - Other - as specified
Resolved 10 December 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 December 2024
Resolved
Provide a list of all crew members currently enrolled in a random drug and alcohol with satisfactory pre-employment testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2024
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 December 2024
Resolved
The bilge high level alarm in the lazarette is barely audible over ambient noise (visual alarm is good). Provide a louder audible alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2023
Resolved
Replace 01 40B:C fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 October 2023
Resolved 18 October 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 October 2023
Resolved
Repair/replace white running light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 October 2023
Resolved 18 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 October 2023
Resolved
Mark ring life buoy with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 October 2023
Resolved 18 October 2023
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 7 November 2022
Resolved
Due to weather conditions in which the vessel would normally not operate, unable to get the vessel underway to test propulsion/steering and conduct a man overboard drill. Conduct sea trials and a man overboard drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 December 2022
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 9 December 2021
Resolved
Exhaust gases cannot reenter the vessel. Excess exhaust is causing high level alarms in passenger areas.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2021
Resolved 10 December 2021
Resolution: Cleaned exhaust aftercooler.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 December 2021
Resolved
Stations in the maritime service must be licensed by the FCC. Ship Station Authorization is expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 18 January 2022
Resolution: New documentation provided.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 9 December 2021
Resolved
Abandon ship drill, man overboard, and fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. None of the above were logged for Coast Guard review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 18 January 2022
Resolution: Drills logged since previous inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 9 December 2021
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Engine belts are exposed and present a hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 18 January 2022
Resolution: Guards provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 December 2021
Resolved
A vessel must carry up-to-date U. S. Coast Pilot and Coast Guard Light List. Light List and Coast Pilot are outdated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 18 January 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020
Resolved
Grind and renew damaged fiberglass on the transom at the starboard exhaust penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020
Resolved
Grind and renew damaged fiberglass on the keel, starboard side aft.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020
Resolved
Grind and renew nicks in fiberglass on the bow, port and starboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020
Resolved
Grind and renew damaged fiberglass on the port cap rail at the midship cleat.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020
Resolved
Properly repair damaged starboard cap rail, midship (approx. 24”).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020
Resolved
Repair abrasion damaged in fiberglass from port and starboard mooring lines
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 October 2020
Resolved
Replace starboard deck drain thru hull fitting in the holding tank space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 October 2020
Resolved
Replace the fuel return line for the starboard engine with approved nonmetallic fuel hose and fittings. 46 CFR 182.720(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 October 2020
Resolved
Replace fuel shutoff valves at the port and starboard fuel tanks. 46 CFR 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 October 2020
Resolved
Make the port and starboard penetrations in the forward engine room bulkhead vapor and water tight. 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2019
Resolved
Provide state registration for vessel, registration shall indicate the vessel is operated in a commercial service.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 1 December 2019
Resolution: Vessel registered
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2019
Resolved
Replace/repair ring buoy, buoy is faded and no longer orange.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 1 December 2019
Resolution: New Life buoy onboard
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 November 2019
Resolved
Provide the following publications in paper form for area of operations: U.S. Coast Pilot [name withheld], Tide Tables and currents.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2019
Resolution: Publications onboard
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2019
Resolved
Remove dead ended wires in battery compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 1 December 2019
Resolution: Wires removed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2019
Resolved
Secure ground bus bar to bulkhead under operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 1 December 2019
Resolution: Bus bar attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 October 2018
Resolved
Repair deck rail on second deck port side by way of ring buoy mount. Deck rail had severe galvanic corrosion.
Action required: 705 - Other - as specified
Resolved 26 October 2018
Resolution: Rail course replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 October 2018
Resolved
Repair and demonstrate proper operation of positive shutoff valve for Port side engine room bilge pump overboard discharge.
Action required: 705 - Other - as specified
Resolved 26 October 2018
Resolution: Handle replaced and valve functioned as intended.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 24 October 2018
Resolved
Grind down to good glass and repair FRP on forward cabin port and STBD lower corners. Corners cracked and holed.
Action required: 705 - Other - as specified
Resolved 26 October 2018
Resolution: Cabin repairs completed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 24 October 2018
Resolved
Grind out bad glass on underside of swim platform STBD side. Make available for re-inspection.
Action required: 705 - Other - as specified
Resolved 26 October 2018
Resolution: Repairs completed to satisfaction of MI.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 24 October 2018
Resolved
Re-frame deck frames in forward compartment and rebuild tabbing on Port side that holds deck frame.
Action required: 705 - Other - as specified
Due 26 October 2018
Resolved 26 October 2018
Resolution: Deck frames re-installed, FRP tabbing to hull re-attached.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 24 October 2018
Resolved
COMPASS MUST BE PROVIDED WITH LIGHT.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2018
Resolved 14 November 2018
Resolution: compass light repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 October 2018
Resolved
BILGE PUMP OPERATION INDICATOR IS NOT FUNCTIONAL
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2018
Resolved 14 November 2018
Resolution: bulb replaced for bilge pump indicator
Stability › Watertight Integrity › General
Issued 6 November 2017
Resolved
Renew all dry-rotted gaskets on watertight hatches.
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 4 December 2017
Resolution: New gaskets installed.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 6 November 2017
Resolved
Provide oil discharge placard
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 9 November 2017
Resolution: Placard installed
Communications › Radio Communications › EPIRB
Issued 6 November 2017
Resolved
Provide current NOAA registration for EPIRB
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 4 December 2017
Resolution: Current EPRIB registration provided.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 6 November 2017
Resolved
Provide at least two portable lights, one must be stowed at operating station.
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 9 November 2017
Resolution: Added 02 portable lights.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 21 December 2016
Resolved
Make repairs to port engine wiring harness
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 10 January 2017
Resolution: Disassembled and cleaned harness connections
Communications › Radio Communications › VHF Radiotelephone
Issued 1 December 2016
Resolved
Program VHF-DSC with MMSI and connect to GPS
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 21 December 2016
Resolution: Programmed VHF-DSC
Lifesaving › Lifefloat › Serviceable
Issued 1 December 2016
Resolved
Make repairs to lifefloat in accordance with manufacture's recommendations
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 21 December 2016
Resolution: Made repairs to lifefloat
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 December 2016
Resolved
Renew 02 PFDs with approved type
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 21 December 2016
Resolution: Renewed PFDs
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 1 December 2016
Resolved
Renew/repair port engine tachometer
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 21 December 2016
Resolution: Renewed tachometer
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 December 2016
Resolved
Provide a first aid kit with required contents
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 21 December 2016
Resolution: Renewed first aid kit
Documentation › Markings/Placards › Warning Signs
Issued 1 December 2016
Resolved
Maximum number of passengers allowed on upper deck must be indicated at entrance way.
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 21 December 2016
Resolution: Labeled entrance way
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 December 2016
Resolved
Label all bilge high level and automatic pump indicators
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 21 December 2016
Resolution: Labeled all indicators
Operations/Management › Pollution › Control of Garbage
Issued 1 December 2016
Resolved
Provide written waste management plan
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 21 December 2016
Resolution: Provided written waste management plan
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 1 December 2016
Resolved
Post emergency broadcast placard
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 1 December 2016
Resolution: Posted emergency broadcast placard
Stability › Watertight Integrity › General
Issued 1 December 2016
Resolved
Make permanent repairs to crack at midship on port and starboard decks
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 10 January 2017
Resolution: Made repairs to deck
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 October 2016
Resolved
Make permanent repairs to port deck rail
Action required: 705 - Other - as specified
Due 27 November 2016
Resolved 16 November 2016
Resolution: Cropped and renewed section of port top rail.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 November 2015
Resolved
Install rails across full stern area no more than 12" apart.
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 4 December 2015
Resolution: Rails installed
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 November 2015
Resolved
Post Waste Management Plan, Garbage Placard, Oil Discharge Placard, Emergency Instructions, Stability Letter, and COI.
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 4 December 2015
Resolution: All documentation posted.
Construction/Loadline › Structures › Machinery Space Opening
Issued 23 October 2014
Resolved
Address wasted hatch cover for engine compartment.
Due 23 November 2014
Resolved 17 November 2014
Resolution: Wasted hatch cover was rewelded and the stainless steel screws were isolated from the aluminum plate.
Engineering › Bilge Water Management System › Pump
Issued 23 October 2014
Resolved
Replace non UL listed bilge pump with approved type.
Due 23 November 2014
Resolved 17 November 2014
Resolution: Bilge pumps were replaced with an approved type per the regulations.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 November 2010
Resolved
Vessel must pot COI and stability letter in a conspicuous place.
Due 8 November 2010
Resolved 8 November 2010
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 8 November 2010
Resolved
Segregate child PFD's from adult
Due 8 November 2010
Resolved 8 November 2010
Communications › Radio Communications › VHF Radiotelephone
Issued 8 November 2010
Resolved
Fill in emergency broadcast placard will vessel particulars.
Due 8 November 2010
Resolved 8 November 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 November 2010
Resolved
Bilge high water level alarm must be audible and visual.
Due 8 November 2010
Resolved 8 November 2010
Stability › Watertight Integrity › General
Issued 27 October 2010
Resolved
Engine room hatch must be in compliance with 46 CFR 179.360
Due 8 November 2010
Resolved 8 November 2010
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 27 October 2010
Resolved
Repair dive ladder to the satisfaction of a USCG marine inspector.
Due 8 November 2010
Resolved 8 November 2010
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 February 2010
Resolved
Life jacket storage location labels are faded, replace placards as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 1 April 2010
Lifesaving › Lifefloat › Lifeline
Issued 17 February 2010
Resolved
Life Float life line holder is broken, repair or replace life line holder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 1 April 2010
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 February 2010
Resolved
Three adult life jackets are unserviceable, reduce passenger count by 3, a total of 37 passengers allowed until new life jackets are provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 23 May 2014
Resolution: 37 total life jackets are installed on the vessel.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 February 2010
Resolved
Provide and post life jacket donning placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 17 February 2010
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 17 February 2010
Resolved
Provide and post E.A.P. placard in area accessible to all employees.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 1 April 2010
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 17 February 2010
Resolved
Provide required training for E.A.P. supervisor.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 1 April 2010
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 February 2010
Resolved
Stencil name of vessel on life buoy, on lower deck.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 1 April 2010
Lifesaving › Lifefloat › Paddle
Issued 8 February 2008
Resolved
Label vessel name on lifefloat paddles.
Due 3 March 2008
Resolved 20 May 2009
Resolution: Cleared old deficiencies.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 February 2008
Resolved
Prove proper operation of the stern light. Vessel is restricted to daylight operations only until this requirement is met.
Due 8 February 2008
Resolved 20 May 2009
Resolution: Cleared old deficiencies.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 8 February 2008
Resolved
Vessel is restricted to the carriage of 38 total passengers (40 total persons) due to quantity of adult lifejackets on board.
Due 8 February 2008
Resolved 20 May 2009
Resolution: Cleared old deficiencies.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 February 2007
Resolved
Vessel does not have a valid COD onboard. Last known valid certificate expired on November 2005.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 February 2007
Resolved 22 February 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 19 February 2007
Resolved
Vessel had 38 adult lifejackets (for passengers) onboard. Obtain 2 adult lifejackets. Vessel is restricted to 38 adult passengers until this requirement is met.
Due 19 February 2007
Resolved 20 May 2009
Resolution: Cleared old deficiencies.
Lifesaving › Lifefloat › Paddle
Issued 19 February 2007
Resolved
Obtain 2 paddles labeled with the vessel's name.
Due 23 February 2007
Resolved 20 May 2009
Resolution: Cleared old deficiencies.
Engineering › Bilge Water Management System › Interface Detector
Issued 19 February 2007
Resolved
Install separate indicator lights to indicate a high level condition in each respective space. Label each light accordingly.
Due 2 March 2007
Resolved 20 May 2009
Resolution: Cleared old deficiencies.
Documentation › Certificates/Documents › FCC SSL
Issued 22 November 2005
Resolved
Provide valid FCC Safety Radio Certificate onboard vessel.
Action required: 705 - Other - as specified
Due 21 December 2005
Resolved 28 November 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 November 2005
Resolved
Mark lifejacket stowage on main deck.
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 28 November 2005
Communications › Alarms/Indicators › Fire Alarm
Issued 22 November 2005
Resolved
Prove proper operation of audible alarm in way of fixed fire extinguishing system.
Action required: 705 - Other - as specified
Due 28 November 2005
Resolved 28 November 2005
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 February 2005
Resolved
Renew worn retro-reflective tape on life-float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2005
Resolved 22 November 2005
Resolution: Witnessed proper operation of vessel''s anchor light.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 February 2005
Resolved
Ensure proper operation of anchor light prior to operation past sunset.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2005
Resolved 22 November 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 8 February 2005
Resolved
Ensure annual service of fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2005
Resolution: Corrected
Engineering › Fuel Oil Service System › Filter
Issued 8 February 2005
Resolved
Provide plug for Raycor fuel filter flame bowl valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2005
Resolution: Corrected.
Operations/Management › Drug and Alcohol Testing
Issued 17 November 2003
Resolved
Prove compliance with Drug Testing Requirements in accordance with 46 CFR Part 16. LEGACY COMPONENT DESC: Proof of Enrollment
Action required: 705 - Other - as specified
Due 2 December 2003
Resolved 28 May 2004
Navigation › Piloting/Steering
Issued 17 November 2003
Resolved
Provide a copy of the Navigation Rules in accordance with 33 CFR 88.05 LEGACY COMPONENT DESC: Inland Navigation Rules
Action required: 705 - Other - as specified
Due 2 December 2003
Resolved 17 November 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 17 November 2003
Resolved
Prior to carrying passengers, prove proper operation of Fixed Extinguishing System alarms and shutdowns. LEGACY COMPONENT DESC: Alarms and Shutdowns
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2003
Resolved 18 November 2003
Resolution: Inspector witnessed proper operation of audible and visual alarms for fixed fire extinguishing system.
Fire Fighting › Miscellaneous Items
Issued 17 November 2003
Resolved
Provide one Fire Bucket in accordance with 46 CFR 181.610 LEGACY COMPONENT DESC: Fire Buckets
Action required: 705 - Other - as specified
Due 2 December 2003
Resolved 28 May 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 17 November 2003
Resolved
Remove expired First Aid Kit items and ensure Kit complies with 46 CFR 160.041(b). LEGACY COMPONENT DESC: First Aid Kit
Action required: 705 - Other - as specified
Due 2 December 2003
Resolved 28 May 2004
Communications › Radio Communications
Issued 9 December 2002
Resolved
Replace EPIRB hydrostatic release prior to carrying passengers. LEGACY COMPONENT DESC: EPIRB hyrdostatic release
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2002
Resolved 18 December 2002
Resolution: New hydrostatic release was installed.
Lifesaving › Buoyant Apparatus
Issued 9 December 2002
Resolved
Provide two paddles for lifefloat and secure not later than 17Dec02 LEGACY COMPONENT DESC: Paddles
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 18 December 2002
Resolution: Paddles were provided and secured to lifefloat.
Engineering › Fuel Oil Service System
Issued 9 December 2002
Resolved
Ensure proper operation of STBD remote fuel shut-off valve prior to carrying passengers LEGACY COMPONENT DESC: Remote fuel shut-off valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2002
Resolved 18 December 2002
Resolution: Valve was observed operating properly.
Lifesaving › Buoyant Apparatus
Issued 9 December 2002
Resolved
Renew retro-reflective tape on lifefloat not later than 17Dec02 LEGACY COMPONENT DESC: Retro-reflective tape
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 18 December 2002
Resolution: All retro-reflective tape was relaced on lifefloat.
Stability › Watertight Integrity
Issued 9 December 2002
Resolved
Correct leaking deck drains inside of #2 compartment not later than 17Dec02 LEGACY COMPONENT DESC: deck drains
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 18 December 2002
Resolution: Observed corrected.
Construction/Loadline › Penetrations
Issued 7 November 2002
Resolved
Install positive shut off or check valves in all over board through hull lines LEGACY COMPONENT DESC: Check valves
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 November 2002
Resolved 18 December 2002
Resolution: Corrected. Inspector removed requirement to install positive closure valves IWO port and stb deck drain overboard discharge lines after re-evaluating exiting location of drains. Valves in this location provide no added value to drain water.
Construction/Loadline › Penetrations
Issued 7 November 2002
Resolved
Renew or repair 2" through hull from MSD discharge. (valve frozen) LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2002
Resolved 18 December 2002
Resolution: Witnessed new valve in proper operating condition.
Accommodation/Occupational Safety › Occupational Safety
Issued 7 November 2002
Resolved
Install mesh, netting or courses on rails so that no space is greater than 4 inches between the top rail and the deck. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 18 December 2002
Resolution: Observed correceted.