MAURY USCG vessel records
← All vessels

AUTO ECO

AUTO ECO is a 2016 freight ship. The Coast Guard has recorded 1 inspection in 2022, along with 2 deficiencies.

Records in 2022. Most recent: inspection, 17 August 2022.

Built
2016
Last inspected
17 August 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 August 2022
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9736365
1745470
Flag
PORTUGAL
Maury page id
psix-1745470

Documentation record

Tonnage as PSIX records it42424 - Convention (Subpart B), Gross Ton
16995 - Dead Weight, Ton
30700 - Displacement, Ton
12727 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

17 August 2022 Deficiency Check · PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7535988

Deficiency record · 2

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2022 Resolved
13101- An audible and visible alarm should be activated before the vapour concentration reaches 20% of the lower explosive limit (LEL). For ventilated ducts around gas pipes in the machinery spaces containing gas fuelled engines, the alarm limit can be set to 30% LEL. The protective system should be activated at a LEL of 40%. When testing the gas detection system vessel crew was not able to demonstrate the closure of the MGV even after gas concentration reached 60%. 74 SOLAS (20) II-1/57 MSC.285(86)5.5.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2022
Resolved 19 August 2022
Resolution: Class provided documentation attesting that this deficiency has been resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2022 Resolved
13101-Gas-related emergency exercises should be conducted at regular intervals. Safety and response systems for the handling of defined hazards and accidents should be reviewed and tested. Vessel has not incorporated gas related emergency exercises into their training program. 74 SOLAS (20) II-1/57 MSC 285(86) 8.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 12 September 2022
Resolution: Vessel submitted notice of class approval 12SEP2022 at 1214. Vessel was notified of determination on the same date at 1415.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.