Records from 2018 to 2022. Most recent: inspection, 20 October 2022.
Documentation record
Registered dimensions (L × B × D)54.0 ft × 15.3 ft × 11.0 ft
Registered tonnagegross 45 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN H. RATLIFF · CYPRESS, CA, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionSail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 4 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Displacement, Gross Ton
45 - Simplified, Gross Ton
40 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 9
20 October 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7581267
14 September 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7311962
22 March 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7184826
29 June 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6990864
11 June 2020
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6975036
15 October 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6834614
9 September 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6807378
25 April 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6399176
9 April 2018
Drydock Exam · DAPI Audit · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6387903
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 September 2021
No resolution recorded
Vessel has gone past the window for its annual inspection without completing an annual inspection.
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 June 2020
Resolved
Have all portable fire extinguishers and the fixed fire fighting system serviced by a certified fire servicing company.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 June 2020
Resolved
Provide vessel's sail rigging preventative maintenance plan for inspection. Rectify deficiencies w/in 90 days.
Action required: 705 - Other - as specified
Due 4 February 2021
Resolved 28 April 2021
Resolution: A copy of the PMP was included in the local vessel electronic files.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2020
Resolved
Must replace handle on seawater inlet valve to main engine to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 29 June 2020
Resolution: Verified during vessel annual inspection
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect persons and the vessel from electrical hazards including fire caused by or originating in electrical equipment and electrical shock. Vessel had a galley microwave plugged into a power strip. Remove microwave or install dedicated outlet for microwave.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 15 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2019
Resolved
Protection from mechanical damage must be specifically considered and all protective covering or shields must be installed to satisfaction of the [name withheld] hose without protective shielding was rubbing against starboard side motor mount. 46 CFR 182.720(D)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 9 September 2019
Resolution: Vessel sent picture of chaffing correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2019
Resolved
Remote fuel shutoff stations must be marked in clear 1 inch letters indicating purpose of the valve and direction of operation. Fuel shutoff for the generator set was not marked as per regulations. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 10 September 2019
Resolution: Vessel sent images of new fuel shut off markings.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 September 2019
Resolved
Each door, hatch or scuttle used as a means of escape must be capable of being opened by 1 person, from either side. A latch was installed securing the door from opening from one side. 46 CFR 177.50
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2019
Resolution: Vessel sent images of the latches removed from the doors of the head.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2019
Resolved
Each floating water light must be attached to the lanyard with a corrosion resistant clip. Clip was missing from arrangement. 46 CFR 180.70(d)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 10 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 9 September 2019
Resolved
Each applicable vessel must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB. Installation date was not etched in. 46 CFR 180.64
Action required: 10 - Deficiency Rectified
Resolved 9 September 2019
Resolution: Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 September 2019
Resolved
Overboard valve for raw water cooling to machinery cannot secured. Crew is to conduct hourly rounds while underway to check for water ingress. Rounds must be logged. Vessel is required to submit repair plan. 46 CFR 176.610(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2019
Resolved 10 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 September 2019
Resolved
Replace the damaged life line hook on stern.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 10 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 July 2018
Resolved
Provide a DAPI program prior to OPS
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2018
Resolved 12 July 2018
Resolution: Completed satifactory DAPI audit
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 July 2018
Resolved
Provide a waterlight for teh ring bouy
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 12 July 2018
Resolution: Provided waterlight
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 July 2018
Resolved
Provide waterlights on PFDs to maintain Oceans route on COI. Vessel reduced Limited Coastwise route.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 5 October 2018
Resolution: Reduced vessel's route to LIMITED COASTWISE therefore PFD waterlights are not required.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 July 2018
Resolved
Provide FCC radio safety certificate
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 12 July 2018
Resolution: Provide radio safety certificate
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 2 July 2018
Resolved
Provide a lock to the sewage overboard discharge valve
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 5 October 2018
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 July 2018
Resolved
Provide plans for approval for the newly installed bow thruster.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 12 July 2018
Resolution: Provided plans approved
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 9 April 2018
Resolved
Provide FCC Radio Operator's Permit
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 12 July 2018
Resolution: Provided FCC licence
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 April 2018
Resolved
Provide proper manual release for life raft
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2018
Resolved 12 July 2018
Resolution: Provided proper manual release