THE DUKE is a 1979 towing vessel. The Coast Guard has recorded 18 inspections since 1999, most recently in July 2026, along with 7 deficiencies and 1 operational control.

Records from 1999 to 2026. Most recent: inspection, 15 July 2026.

Built
1979
Last inspected
15 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 15 July 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 13 calendar years (1999–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH9149
175099
Flag
UNITED STATES
Maury page id
psix-175099

Documentation record

Registered dimensions (L × B × D)56.1 ft × 24.1 ft × 9.6 ft
Registered tonnagegross 132 / net 90
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKROTZ SPRINGS, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORTH LITTLE ROCK, AR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it132 - Regulatory (Subpart C or D), Gross Ton
90 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

15 July 2026 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8439197
26 June 2025 COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8168174
4 April 2025 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8102393
7 August 2024 Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7976448
10 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7931830
13 July 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7725647
13 July 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7505778
12 August 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7285716
4 June 2021 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7215296
9 July 2020 Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7012957
14 November 2014 DAPI Audit · Deficiency Check · Administration · Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5026354
21 June 2011 Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4051369
13 December 2010 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3909947
9 November 2010 Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3887802
9 November 2010 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3896459
14 June 2001 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 214193
13 July 2000 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 213905
16 July 1999 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 214472

Deficiency record · 7

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2024 Resolved
Machinery systems must be designed and maintained to provide for safe operator of the towing vessel under normal and emergency conditions. Both port and starboard steering rudder post were found to have excessive play within the rudder tube. Additionally, half of the nylon washer bearing underneath the port rudder yoke is missing. Operator must arrange for repairs to be made and submit proposal to the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2024
Resolved 8 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2024 Resolved
Machinery systems must be designed and maintained to provide for safe operator of the towing vessel under normal and emergency conditions. Exhaust leak was found between the exhaust manifold and head on the starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 June 2024 Resolved
Generator engines must be equipped with gauges to measure lube oil pressure, cooling water temperature, and engine RPM. Starboard generator is not equipped with an RPM gauge. Port generator RPM gauge is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 June 2024 Resolved
The master must ensure that all hatches, doors, and other openings designed to be weather watertight or weather-tight function properly. The foward hold weather-tight door gasket is damage and cannot form a weather-tight seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2024
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 13 July 2023 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (1) Main engine low lubricating oil pressure; (2) Main engine high cooling water temperature; (3) Auxiliary generator engine low lubricating oil pressure; (4) Auxiliary generator engine high cooling water temperature; (5) High bilge levels; (6) Low hydraulic steering fluid levels Port main engine jacket water alarm was inoperable. Starboard main engine oil pressure gauge was broken and unable to test alarm function. Steering system does not have an installed low level alarm. Repair jacket water alarm function. Replace oil pressure gauge. Install alarm device for low hydraulic fluid. Ensure all alarms function w/ audible and visual notification.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 22 August 2023
Resolution: tested alarms
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2023 Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. Pressure vessel relief valves: Twice every 5 years, with no more than 3 years elapsing since last test. Air receiver pressure relief valves have not been tested. Test pressure relief valves in accordance with manufacturer instructions or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 19 August 2023
Resolution: Received objective evidence.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 July 2023 Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Fire alarm panel has not been inspected. Provide objective evidence that the fire alarm panel has been inspected in accordance with manufacturer instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 22 August 2023

Ownership record