Records from 1996 to 2009. Most recent: inspection, 7 July 2009.
Inspection history · 20
7 July 2009
Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3549291
14 January 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3124708
9 February 2007
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2869472
20 April 2006
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2625806
9 February 2006
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2585772
13 October 2005
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2513175
24 January 2005
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2279695
22 November 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2245712
22 October 2004
Examination of Repairs · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2223915
27 October 2003
Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1945326
24 October 2003
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2070329
12 August 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1861752
19 September 2002
Deficiency Check · Annual Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1667948
3 April 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1600540
28 August 2000
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1440374
3 December 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 809872
8 October 1998
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 806710
19 June 1998
Simplified Stability Test
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 801069
24 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 764088
11 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 206056
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 14 January 2008
No resolution recorded
Captain must undergo pre-employment drug testing since enrolment in drug consortium lapsed over 4 months ago.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 January 2008
No resolution recorded
Must conduct fire and man overboard drills in the presence of CG Marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 January 2008
No resolution recorded
Provide adequate operable emergency lighting for spaces below main deck. 3 or 4 lanterns were non-operational.
Action required: 701 - Prior to carriage of passengers/cargo
Stability › Watertight Integrity › General
Issued 14 January 2008
No resolution recorded
Adjust excessive leaking on port propulsion stuffing box to minimal leakage.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 January 2008
No resolution recorded
Provide 5/16 diameter synthetic/ ultraviolet light resistant, non-kinking lifeline at least 60 feet in length for ring buoy. Current line on ring buoy is improper diameter size.
Action required: 705 - Other - as specified
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 January 2008
No resolution recorded
Mark ring buoy with vessel's name. Current markings are worn and un-recognizable.
Action required: 705 - Other - as specified
Lifesaving › Lifebuoys › Serviceable
Issued 14 January 2008
No resolution recorded
Provide retro-reflective tape on both sides of ring buoy. Ring buoy had retro-reflective tape on one side only.
Action required: 705 - Other - as specified
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 14 January 2008
No resolution recorded
Provide proof of active EAP program.
EAP training not be conducted, numbers not being provided to crew & no signs posted. No evidence of any EAP.
Action required: 705 - Other - as specified
Stability › Watertight Integrity › General
Issued 14 January 2008
No resolution recorded
Seal fasteners IWO swim platform at the Aft bulkhead of steering compartment (where fuel shut-off valves are located). Bolts are leaking by. To be completed by next dry-dock
Action required: 705 - Other - as specified
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 March 2007
Resolved
Provide all vital systems with two separate sources of electrical power that can be readily utilized in the case of power failure of any one electrical source.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2007
Resolution: Verified additional electrical source and tested bilge pumps using both sources with the other disconnected.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 7 March 2007
Resolved
Prior to operating with passengers on March 8, 2007 from 4-7 pm, you must provide 2 BII portable fire extinguishers, 1 extra deckhand to conduct and log 15 minute rounds of engineroom, and provide 2 UL-217 smoke detectors verified as satisfactory by a CG MI.
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 8 March 2007
Resolution: All conditions above were met and verified as satisfactory by a CG Marine Inspector.
Engineering › Lubricating Oil Service System › Gauge
Issued 7 March 2007
Resolved
Repair lube oil gauge on stbd main engine.
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 13 November 2007
Resolution: Gauge was repaired.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 March 2007
Resolved
Repair jacket water temperature gauge for port/stbd main engines on operation station.
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 13 November 2007
Resolution: Gauges were repaired and tested SAT.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 March 2007
No resolution recorded
Repair lube oil leaks on generator.
Action required: 705 - Other - as specified
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 March 2007
No resolution recorded
Repair jacket water leaks on generator.
Action required: 705 - Other - as specified
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 March 2007
No resolution recorded
Install machinery guard on generator.
Action required: 705 - Other - as specified
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 7 March 2007
Resolved
Repair rescue platform.
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 7 March 2007
Resolution: Weight tested platform to 500 lbs.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 March 2007
No resolution recorded
Repair forward engine mounts on generator.
Action required: 705 - Other - as specified
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 7 March 2007
Resolved
Provide service report for port/stbd main engines from certified repair technician.
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 8 March 2007
Resolution: Received a copy of the report.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 7 March 2007
No resolution recorded
Provide service report for generator from certified repair technician.
Action required: 705 - Other - as specified
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 7 March 2007
Resolved
Provide a properly installed and operationable FFFE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2007
Resolution: FFE bottle was installed and tested SAT.
Documentation › Certificates/Documents › FCC SSL
Issued 13 October 2005
Resolved
Provide proof of a Safety Radio Certificate, until such time the vessel is restricted to 1000 ft. from shore.
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 4 January 2007
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 13 October 2005
Resolved
Provide proof of enrollment in drug consortium.
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 2 February 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 October 2005
Resolved
Provide a Coast Guard Light List.
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 2 February 2006
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 13 October 2005
Resolved
Provide Local Notice to Mariners.
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 2 February 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 October 2005
Resolved
Provide Tide Tables and Tidal Current Tables.
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 2 February 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 October 2005
Resolved
Provide a U.S. Coast Pilot.
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 2 February 2006
Lifesaving › Lifebuoys › Serviceable
Issued 13 October 2005
Resolved
Repair or replace, hand hold line is deteriorated.
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 2 February 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 October 2005
Resolved
Repair the emergency lights as needed.
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 2 February 2006
Lifesaving › Lifebuoys › Serviceable
Issued 22 November 2004
Resolved
INSTALL 4 STRIPS OF CLASS I RETROREFLECTIVE MATERIAL ON EACH SIDE OF LIFERING PRIOR TO CARIAGE OF PASSENGERS.
Due 6 December 2004
Resolved 24 January 2005
Resolution: Type II retroflective tape affixed to lifering.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 November 2004
Resolved
STENCIL NAME OF VESSEL ON LIFERING PRIOR TO CARRIAGE OF PASSENGERS.
Due 6 December 2004
Resolved 24 January 2005
Resolution: Name of vessel stenciled on lifering
Engineering › Bilge Water Management System › Not Operational
Issued 22 November 2004
Resolved
REPAIR ENGINE ROOM HIGH LEVEL ALARM IN ENGINE ROOM PRIOR TO CARRIAGE OF PASSENGERS.
Due 6 December 2004
Resolved 24 January 2005
Resolution: BIlge high level alarm for engine room repaired. Operational test conducted for visual/audible alarm.
Engineering › Bilge Water Management System › Not Installed
Issued 22 November 2004
Resolved
INSTALL ADDITIONAL HIGH LEVEL ALARM IN FORWARD VOID WITH AUDIBLE/VISUAL ALARM AT OPERATING STATION.
Due 22 December 2004
Resolved 24 January 2005
Resolution: Bilge alarm in FWD void not required: Limber hole in BKHD at keel allows for water flow into engine room bilge (already protected by high level alarm).
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 November 2004
Resolved
REAPAIR MAST HEAD AND STBD RUNNING LIGHTS PRIOR TO OPERATION AT NIGHT.
Due 22 December 2004
Resolved 24 January 2005
Resolution: Conducted operational test of nav lights. All navigational lights operating properly.
Personnel › Certificates/Documents/Licenses
Issued 12 August 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 12 August 2003
Resolved 5 December 2003
Resolution: VALID COPY SUBMITTED.
Lifesaving › Hand Flares
Issued 5 September 2002
Resolved
PROVIDE 3 ADDITIONAL HAND HELD FLARES PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Quantity
Condition: Placed in Improper Service
Due 19 September 2002
Resolved 19 September 2002
Resolution: CORRECTED.
Operations/Management › Drug and Alcohol Testing
Issued 5 September 2002
Resolved
PROVIDE CURRENT CONSORTIUM CONTRACT AND UPDATED EMPLOYEE LIST. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Due 19 September 2002
Resolved 19 September 2002
Resolution: INFORMATION PROVIDED.
Engineering › Fuel Oil Storage/Transfer System
Issued 5 September 2002
Resolved
INSTALL PLUGS ON FUEL FILTER DRAINS. LEGACY COMPONENT DESC: Filter/Strainer
Condition: Improper Installation
Due 19 September 2002
Resolved 19 September 2002
Resolution: WITNESSED PLUG INSTALLATION.
Construction/Loadline › Penetrations
Issued 5 September 2002
Resolved
MAKE AVAILABLE ALL REMAINING SEA VALVES FOR INSPECTION. LEGACY COMPONENT DESC: Sea Valves
Due 19 September 2002
Resolved 19 September 2002
Resolution: WITNESSED VALVES - SAT.
Documentation › Certificates/Documents
Issued 5 September 2002
Resolved
UPDATE CURRENT ADDRESS WITH NATIONAL VESSEL DOCUMENTATION CENTER.
Due 5 October 2002
Resolved 19 September 2002
Resolution: INFORMATION SUBMITTED.