Records from 1990 to 2021. Most recent: inspection, 29 July 2021.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
29 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7272559
24 June 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7234406
20 October 2020
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7081147
17 October 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6854771
16 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6836372
18 July 2019
Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6758421
24 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6568941
24 September 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6547743
27 November 2017
Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6313423
21 June 2016
Administrative Inspection · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5914228
17 November 2015
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5765360
29 September 2011
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4158226
30 July 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3571818
9 June 2008
Internal Structural Exam · Examination of Repairs · Re-Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3231561
22 October 2007
Damage Survey · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3084635
12 October 2006
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2798959
22 November 2005
Examination of Repairs · COI Inspection · Hull Examination · Ballast Water Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2538924
19 July 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2137982
6 June 2003
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1811126
26 April 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1608945
28 September 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457012
26 May 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468140
18 October 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452577
28 July 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445365
7 October 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464723
20 September 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779240
18 July 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1089838
18 July 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431659
12 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1090039
12 May 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 760075
10 May 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 197933
9 May 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392221
2 May 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 868794
21 November 1994
Deficiency Check · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419336
24 May 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1169844
24 September 1993
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410856
9 December 1992
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 827010
1 June 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359406
23 April 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226682
18 April 1990
Inclining Experiment · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238345
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 20 October 2020
Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's stability letter. The vessel may not depart until it is in compliance with these requirements. The vessel master was unfamiliar with how to perform loading calculations in accordance with the vessels stability letter and approved operations manual. Company shall ensure all masters responsible for the stability of the vessel is adequately trained to perform necessary stability loading calculations. 46 CFR 185.315(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2020
Resolution: Master was provided training by company and completed mock stability calculation in compliance with vessels stability letter and operations manual.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 20 October 2020
Resolved
The master shall conduct sufficient drills and give sufficient instruction to make sure that all crew members are familiar with their duties during emergencies that necessitate abandon ship or the recovery of persons who have fallen overboard. Abandon ship drills and training shall be logged or otherwise documented. The drill entry shall include the date of the drill and training and the general description of the drill scenario and training topics. The vessels master could not provide logs or evidence of man overboard or abandon ship drills and training as required by regulation. Vessel completed proper drills to the satisfaction of the Coast Guard. Vessel shall perform training on emergency procedures and provide documentation to the Coast Guard prior to departure. 46 185.420(a),(c) & (f)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2020
Resolution: Vessel master completed training and company provided updated emergency procedures.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 October 2020
Resolved
The Master of the vessel shall ensure that: Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel was missing required monthly EPIRB test in the vessel log. Vessel shall conduct required monthly test of EPIRB and log it in the vessel log book. 46 CFR 185.728(c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 October 2020
Resolution: Corrected on the spot. Vessel conducted an EPIRB check in the presence of the MI and MI informed vessel to ensure tests and log entries are performed every month.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 October 2020
Resolved
The Master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Grab lines for stern life ring buoy was in a deteriorated condition. Vessel shall replace grab line on stern life ring buoy. Additionally the line throw bag had string wrapped around the opening, preventing immediate use. 46 CFR 141.230
Action required: 10 - Deficiency Rectified
Resolved 20 October 2020
Resolution: Vessel replaced life bouy.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 October 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. The vessels chart for area of operation was printed on October 2019 and did not contain any chart corrections until week 36/20. Also the vessel latest Notice to Mariner was not on board. Vessel must ensure charts are maintained continuously throughout the validity of the vessels COI. 46 CFR 184.420
Action required: 10 - Deficiency Rectified
Resolved 20 October 2020
Resolution: Corrected on the spot. Vessel informed chart corrections shall be maintained throughout the year and not corrected one time prior to CG inspection.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 October 2020
No resolution recorded
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the end of the fuel line to stop fuel flow when servicing accessories. During inspection it was discovered that the emergency fuel shut off valve was located approximately 10' from the valve installed at the fuel tank. Vessel shall alter placement of emergency fuel shut off valve to be located at the closest valve to the fuel tanks at next drydock. 46 CFR 182.20-45(b)(2)
Action required: 705 - Other - as specified
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 October 2019
Resolved
Missing current charts for areas of operation. Charts onboard were from 2018.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 October 2019
Resolution: Received email with receipt for current charts that were purchased.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 October 2019
Resolved
Missing documentation in log book of monthly EPIRB test.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2019
Resolution: Received email with photo of documentation in log book for monthly EPIRB test.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 October 2019
Resolved
Missing documentation in log book of fire, abandon ship, and MOB drills being conducted.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2019
Resolution: Received email with photo of documentation in log book for fire, abandon ship, and MOB drills conducted.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 16 October 2019
Resolved
Captain could not provide proof of a valid Marine Radio Operator Permit.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2019
Resolution: Received email with photo of valid Marine Radio Operator Permit for vessel Captain.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 October 2019
Resolved
Port ring buoy 90' bag of line was wasted.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2019
Resolution: Received email with photo and receipt for 90' bag of line for the port ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2019
Resolved
Test or replace safety relief valve on pressure vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2019
Resolution: Received email with receipt for new safety relief valve that was purchased for the pressure vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2019
Resolved
Install additional wrapping on keel cooler piping.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2019
Resolution: Received email with photo showing additional wrapping installed on the keel cooler piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2019
Resolved
Install additional wrapping on stbd MDE exhaust.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2019
Resolution: Received email with photo showing additional wrapping installed on the stbd MDE exhaust.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2018
Resolved
Port lifebuoy line was wasted. Required new line be installed. 46 180.70(a)(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018
Resolved 25 September 2018
Resolution: Line was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 September 2018
Resolved
The jacking system should incorportate a "dead man" device at the system controls to secure jacking if applied force to controls is removed. Device used would not secure jacking. Once foot pedal pressure was removed the hydraulic plate used to return controls to "off" would not move levers to secure jacking operation. CG 543 Policy Ltr Enc 1, Para 11.b
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2018
Resolved 24 October 2018
Resolution: Tested switch after crew repaired. Tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 September 2018
Resolved
Fuel tank vent screen 30x30 mesh was holed from check valve wearing on screen. 46 CFR 182.450
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Fuel vent screen was replaced.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 September 2018
Resolved
Epirb battery was expired on 7/2018. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2018
Resolution: Replacement EPIRB was installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 September 2018
Resolved
EPIRB Hydrostatic release was expired from 2017. 46 CFR 185.740 .
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2018
Resolved 26 September 2018
Resolution: Hydrostatic release was replaced with new.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 September 2018
Resolved
Life float is required 2 paddles. Vessel's life float was missing both. 46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2018
Resolved 26 September 2018
Resolution: Paddles provided for life float.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 September 2018
Resolved
Vessel is required to have a rescue boat due to the nature of its work making it restricted in its ability to maneuver. Rescue boat engine was inoperable to to a fuel filter leak.
46 CFR 180.210(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2018
Resolution: Fuel filter was repaired with a new o-ring and test ran. Satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 September 2018
Resolved
Fire extinguisher mounted to protect pain locker had a wasted bracket. Requires replacement. 46 CFR 181.500(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2018
Resolved 26 September 2018
Resolution: Fire extinguisher bracket was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 24 September 2018
Resolved
Magnetic compass is required a light unless vessel is operating only in daylight. Vessel operates 24/7 and requires light. 46 CFR 184.402(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2018
Resolution: Compass light was repaired.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 September 2018
Resolved
Remote fuel shut off vavle on main deck did not have directions showing how to operate. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2018
Resolution: Remote fuel cut off valve on main deck was stenciled with means of closing.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 September 2018
Resolved
Emergency escape hatch leading from Engine room was unable to be opened from the inside. Crew to adjust hatch. 46 CFR 46 177.15-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2018
Resolution: Escape hatch was adjusted and tested satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 21 June 2016
Resolved
PFD was missing the required attached light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 22 July 2016
Resolution: Attached a new PFD light; corrected on the spot.
Engineering › Fuel Oil Service System › Piping
Issued 19 July 2004
Resolved
Repair fuel oil leak at fitting on ships service generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2004
Resolution: Leak repaired by crew.
Lifesaving › Lifefloat › Serviceable
Issued 19 July 2004
Resolved
Replace weathered life float and water light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2004
Resolution: Replaced with unit from local supplier
Stability › Watertight Integrity › General
Issued 19 July 2004
Resolved
Clean and lubricate engine room escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2004
Resolution: Corrected by crew.
Construction/Loadline › Hull › Hull Plating
Issued 6 June 2003
Resolved
Crop and renew as necssary due to damage or wastage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2003
Resolution: Plate summary in vessel fiel at MORMS
Lifesaving
Issued 18 October 1999
Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District Policy Ltr. dated 12NOV98 "Rescue Boat Requirements on Offshore Supply Vessels" to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Documentation
Issued 18 April 1990
Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990
Documentation
Issued 18 April 1990
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld].
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990
Documentation
Issued 18 April 1990
Resolved
SUBMIT STABILITY CALCULATIONS TO THE COAST GUARD MARINE SAFETY CENTER FOR ISSUANCE OF A STABILITY LETTER.
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990
Documentation
Issued 18 April 1990
Resolved
PROVIDE ON BOARD A ROUGH COPY OF AN OPERATING MANUAL MEETING THE APPLICABLESECTIONS OF 46 CFR 109.121.
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990