MAURY USCG vessel records
← All vessels

SUN PRINCESS

SUN PRINCESS is a 2024 passenger vessel (inspected). The Coast Guard has recorded 5 inspections since 2023, most recently in November 2025, along with 6 deficiencies.

Records from 2023 to 2025. Most recent: inspection, 16 November 2025.

Built
2024
Last inspected
16 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 November 2025
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2023–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9863118
1761810
Flag
BERMUDA
Maury page id
psix-1761810

Documentation record

Tonnage as PSIX records it177882 - Convention (Subpart B), Gross Ton
169552 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

16 November 2025 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8262405
7 November 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8031940
11 October 2024 COC-CVE Initial · PSC A · COC-TVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8017871
16 February 2024 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7871578
12 September 2023 COC-CVE Initial Prep · COC-CVE Initial
Administrative · Activities Europe · Activity 7791958

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 November 2025 Resolved
Openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed fire door 18.5.05 and 18.5.03 found within the spa ajar and unable to close. The spa was currently closed with no staff visible, and both doors (at least one storing nail polish) had their deadbolts open to prevent door closure. 74 SOLAS (20) II-2/9.4.1.1.1 Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 November 2025
Resolution: Deadbolts closed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 November 2025 Resolved
Escape doors from public spaces that are normally ltched shall be fitted with a meansof quick release. Such means shall consist of a door-latching mechanism incorperating a device that releases the latch upon the application of a force in the escape flow. PSCO observed Sanctuary Club main entrance decorative door equipped with a locking device that prevents the release of the latch when pressure is applied to the releasing device. 74 SOLAS (20) II-2 /13.3.2.6.2 Code 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 16 November 2025
Resolution: Locking device removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 October 2024 Resolved
Doors in escape routes shall, in general, open in way of the direction of escape. PSCOs observed two escape doors on deck 18 in the globe theatre leading to the open deck open against the flow of emergency exit. 74 SOLAS 20 II-2/13.3.1.5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2024
Resolved 7 November 2024
Resolution: Doors replaced and now open outwards to the direction of exit.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 October 2024 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. Not be equipped with any locking device, set screw or other arrangements that prevents the release of the latch when pressure is applied to the releasing device. PSCOs observed thumb lock on deck 8 glass dome theatre doors leading out to the open deck, which is an emergency exit. 74 SOLAS 20 II-2/13.3.2.6.2.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2024
Resolved 7 November 2024
Resolution: latch removed, pictures attached
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 October 2024 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Mid passenger stairway crew guides for deck 05, 06, and 12 were not familiar with emergency procedures. 74 SOLAS 20 III/19.2.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 October 2024
Resolved 15 October 2024
Resolution: Vessel Staff Captain provided trainning documentation for starway guides.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 October 2024 Resolved
Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler of an approved type complying with the requirements of the Fire Safety Systems Code in all control stations, accommodation and service spaces, including corridors and stairways. PSCOs observed missing ampule in one of two high pressure water mist nozzles in the sauna on Deck 6/MVZ 4. 74 SOLAS 20 II-2/10.6.1.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 October 2024

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.